Bone is the most common site of metastasis in breast cancer. Metastasis is promoted by acidosis, which is associated with osteoporosis. To investigate how acidosis could promote bone metastasis, we compared differentially expressed genes (DEGs) in MDA-MB-231 cancer cells in acidosis, bone metastasis, and bone metastatic tumors.

View Article and Find Full Text PDF

The human body experiences physiological changes under microgravity environment that phenocopy aging on Earth. These changes include early onset osteoporosis, skeletal muscle atrophy, cardiac dysfunction, and immunosenescence, and such adaptations to the space environment may pose some risk to crewed missions to Mars. To investigate the effect of microgravity on aging, many model organisms have been used such as the nematode Caenorhabditis elegans, the fruit fly Drosophila melanogaster, and mice.

View Article and Find Full Text PDF

A 3D-printed cartridge was developed to improve the interface between a capillary electrophoresis instrument and a mass spectrometer. The thermostated airflow from the CE was guided to the entrance of the electrospray source keeping as much as possible the silica capillary in a proper Joule-heating dissipation environment. Hollow 3D-printed walls made of ABS covered by a 0.

View Article and Find Full Text PDF

Hemiesters of carbonic acid can be freely formed in aqueous media containing HCO3(-)/CO2 and mono- or poly-hydroxy compounds. Herein, (13)C NMR spectroscopy was used to identify isomers formed in aqueous solutions of glycerol (a prototype compound) and seven carbohydrates, as well as to estimate the equilibrium constant of formation (Keq). Although both isomers are formed, glycerol 1-carbonate corresponds to 90% of the product.

View Article and Find Full Text PDF

A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C(4) Ds). The first C(4) D was positioned inside the original cartridge, and the second C(4) D was positioned as close as possible to the ESI probe entrance by using a 3D-printed support. The C(4) Ds electropherograms were matched to the ESI-MS electropherogram by correcting their timescales by the factor LT /LD , where LT and LD are the total capillary length and the length until the C(4) D, respectively.

View Article and Find Full Text PDF

ESI sources continuously consume the liquid at the tip of the capillary, which causes the dragging of the BGE. The laminar nature of this flow causes the broadening of the peaks and loss of separation efficiency. The usual solution for this problem is to compensate this phenomenon by reducing the pressure at the inlet vial by either leveling of this vial or pumping off the air that is over it.

View Article and Find Full Text PDF

An all-in-one version of a capacitively coupled contactless conductivity detector is introduced. The absence of moving parts (potentiometers and connectors) makes it compact (6.5 cm(3)) and robust.