Publications by authors named "Keith R Lykke"

Recent developments at the National Institute of Standards and Technology's facility for Spectral Irradiance and Radiance responsivity Calibrations using Uniform Sources (SIRCUS) are presented. The facility is predicated on the use of broadly tunable narrow-band lasers as light sources in two key radiometric calibration applications. In the first application, the tunable lasers are used to calibrate the spectral power responsivities of primary standard detectors against an absolute cryogenic radiometer (ACR).

View Article and Find Full Text PDF

Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities.

View Article and Find Full Text PDF

Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field of view of the instrument nor act as calibrated sources of light.

View Article and Find Full Text PDF

Compact hyperspectral sensors potentially have a wide range of applications, including machine vision, quality control, and surveillance from small Unmanned Aerial Vehicles (UAVs). With the development of Indium Gallium Arsenide (InGaAs) focal plane arrays, much of the Short Wave Infra-Red (SWIR) spectral regime can be accessed with a small hyperspectral imaging system, thereby substantially expanding hyperspectral sensing capabilities. To fully realize this potential, system performance must be well-understood.

View Article and Find Full Text PDF

We have studied the performance of polytetrafluoroethylene integrating spheres in the ultraviolet (UV) region with wavelengths as short as 200 nm. Two techniques were used for this study; first, the spectral throughput of an integrating sphere irradiated by a deuterium lamp was analyzed by a monochromator. Second, a UV laser beam was directed into an integrating sphere, and spectrally dispersed laser induced fluorescence was studied.

View Article and Find Full Text PDF

Independent methods for measuring the absolute spectral irradiance responsivity of detectors have been compared between the calibration facilities at two national metrology institutes, the Helsinki University of Technology (TKK), Finland, and the National Institute of Standards and Technology (NIST). The emphasis is on the comparison of two different techniques for generating a uniform irradiance at a reference plane using wavelength-tunable lasers. At TKK's Laser Scanning Facility (LSF) the irradiance is generated by raster scanning a single collimated laser beam, while at the NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources (SIRCUS), lasers are introduced into integrating spheres to generate a uniform irradiance at a reference plane.

View Article and Find Full Text PDF

The development of a radiation thermometer calibrated for spectral radiance responsivity using cryogenic, electrical-substitution radiometry to determine the thermodynamic temperatures of the Ag- and Au-freezing temperatures is described. The absolute spectral radiance responsivity of the radiation thermometer is measured in the NIST Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) facility with a total uncertainty of 0.15% (k=2) and is traceable to the electrical watt, and thus the thermodynamic temperature of any blackbody can be determined by using Planck radiation law and the measured optical power.

View Article and Find Full Text PDF

A new facility for measuring irradiance in the UV was commissioned recently at the National Institute of Standards and Technology (NIST). The facility uses the calculable radiation from the Synchrotron Ultraviolet Radiation Facility as the primary standard. To measure the irradiance from a source under test, an integrating sphere spectrometer-detector system measures both the source under test and the synchrotron radiation sequentially, and the irradiance from the source under test can be determined.

View Article and Find Full Text PDF

Detectors have historically been calibrated for spectral power responsivity at the National Institute of Standards and Technology by using a lamp-monochromator system to tune the wavelength of the excitation source. Silicon detectors can be calibrated in the visible spectral region with combined standard uncertainties at the 0.1% level.

View Article and Find Full Text PDF

A simple, practical method has been developed to correct a spectroradiometer's response for measurement errors arising from the instrument's spectral stray light. By characterizing the instrument's response to a set of monochromatic laser sources that cover the instrument's spectral range, one obtains a spectral stray light signal distribution matrix that quantifies the magnitude of the spectral stray light signal within the instrument. By use of these data, a spectral stray light correction matrix is derived and the instrument's response can be corrected with a simple matrix multiplication.

View Article and Find Full Text PDF

We have measured the stability of a variety of photodiodes exposed to 157-nm light from a pulsed excimer laser by using a radiometry beamline at the Synchrotron Ultraviolet Radiation Facility at the National Institute of Standards and Technology. The intense, pulsed laser light exposed the photodiodes, whereas the low-intensity, continuously tunable light from the synchrotron source measured changes in the characteristics of the photodiodes, such as in the responsivity and the reflectance from the surface of a photodiode. Photodiodes studied include both silicon pn-junction and Schottky-barrier types.

View Article and Find Full Text PDF

The quantum yield (QY) of the iodide-iodate chemical actinometer (0.6 M KI-0.1 M KIO3) was determined for irradiation between 214 and 330 nm.

View Article and Find Full Text PDF

We have constructed and characterized a simple probe that is suitable for accurate measurements of irradiance in the UV to the vacuum UV spectral range. The irradiance meter consists of a PtSi detector located behind a 5-mm-diameter aperture. The probe was characterized at various wavelengths ranging from 130 to 320 mm by use of continuously tunable synchrotron radiation from the Synchrotron Ultra-violet Radiation Facility III.

View Article and Find Full Text PDF