To assess the diagnostic confidence of intraoral radiographic image quality while reducing the pediatric patient's radiation exposure using a longer position indicating device (PID), additional X-ray beam filtration and rectangular collimation while using modern, lower-power intraoral dental X-ray units.
A randomized prospective study scored bitewing intraoral dental images based on relevant clinical features. Observer studies with pediatric dentists and dental residents were conducted to verify whether diagnostic confidence remained unchanged after dose reduction modifications.
J Appl Clin Med Phys
September 2022
The purpose of this study was to provide an empirical model to develop reference air kerma (RAK) alert levels as a function of patient thickness or age for pediatric fluoroscopy for any institution to use in a Quality Assurance program. RAK and patient thickness were collected for 10&663 general fluoroscopic examinations and 1500 fluoroscopically guided interventions (FGIs). RAK and patient age were collected for 6137 fluoroscopic examinations with mobile-C-arms (MC).
View Article and Find Full Text PDFBackground Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed.
View Article and Find Full Text PDFPurpose: Recently, medical professionals have reconsidered the practice of routine gonadal shielding for radiographic examinations. The objective of this study was to evaluate the gonadal dose reduction achievable with gonadal shields in the primary beam during abdominal/pelvic radiographic examinations under ideal and non-ideal shielding placement.
Methods: CT scans of CIRS anthropomorphic phantoms were used to perform voxelized Monte Carlo simulations of the photon transport during abdominal/pelvic radiographic examinations with standard filtration and 0.
Background The American College of Radiology Dose Index Registry for CT enables evaluation of radiation dose as a function of patient characteristics and examination type. The hypothesis of this study was that academic pediatric CT facilities have optimized CT protocols that may result in a lower and less variable radiation dose in children. Materials and Methods A retrospective study of doses (mean patient age, 12 years; age range, 0-21 years) was performed by using data from the National Radiology Data Registry (year range, 2016-2017) (n = 239 622).
View Article and Find Full Text PDFDiagnostic x-ray exams irradiate the patient to produce an x-ray pattern in space, which is captured and processed into a visible image, followed by clinical interpretation. Diagnostic-quality images at a well-managed radiation dose are required. Improvements to image receptors and image processing algorithms have resulted in improved images at reduced dose levels.
View Article and Find Full Text PDFThe ACR Dose Index Registry (DIR) provides a new source of clinical radiation exposure data that has not been used previously to establish or update the relative radiation level (RRL) values in the ACR Appropriateness Criteria (AC). The results of a recent review of DIR data for 10 common CT examinations were compared with current ACR AC RRL values for the same procedures. The AC RRL values were previously determined by consensus of members of the AC Radiation Exposure Subcommittee based on reference radiation dose values from the literature (when available) and anecdotal information from individual members' clinical practices and experiences.
View Article and Find Full Text PDFObjective: Imaging registries afford opportunities to study large, heterogeneous populations. The purpose of this study was to examine the American College of Radiology CT Dose Index Registry (DIR) for dose-related demographics and metrics of common pediatric body CT examinations.
Materials And Methods: Single-phase CT examinations of the abdomen and pelvis and chest submitted to the DIR over a 5-year period (July 2011-June 2016) were evaluated (head CT frequency was also collected).
There is a need for consensus recommendations for ionizing radiation dose optimization during multimodality medical imaging in children with congenital and acquired heart disease (CAHD). These children often have complex diseases and may be exposed to a relatively high cumulative burden of ionizing radiation from medical imaging procedures, including cardiac computed tomography, nuclear cardiology studies, and fluoroscopically guided diagnostic and interventional catheterization and electrophysiology procedures. Although these imaging procedures are all essential to the care of children with CAHD and have contributed to meaningfully improved outcomes in these patients, exposure to ionizing radiation is associated with potential risks, including an increased lifetime attributable risk of cancer.
View Article and Find Full Text PDFPurpose To determine diagnostic reference ranges on the basis of the size of a pediatric patient's chest and to develop a method to estimate computed tomographic (CT) scanner-specific mean size-specific dose estimates (SSDEs) as a function of patient size and the radiation output of each CT scanner at a site. Materials and Methods The institutional review boards of each center approved this retrospective, HIPAA-compliant, multicenter study; informed consent was waived. CT dose indexes (SSDE, volume CT dose index, and dose length product) of 518 pediatric patients (mean age, 9.
View Article and Find Full Text PDFThe purpose of this study was to reduce pediatric doses while maintaining or improv-ing image quality scores without removing the grid from X-ray beam. This study was approved by the Institutional Animal Care and Use Committee. Three piglets (5, 14, and 20 kg) were imaged using six different selectable detector air kerma (Kair) per frame values (100%, 70%, 50%, 35%, 25%, 17.
View Article and Find Full Text PDFDue to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, "dose-area-product" (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008.
View Article and Find Full Text PDFObjective: The objective of our study was to survey radiation dose indexes of pediatric peripheral and abdominal fluoroscopically guided procedures from which estimates of diagnostic reference levels (DRLs) can be proposed for both a standard fluoroscope and a novel fluoroscope with advanced image processing and lower radiation dose rates.
Materials And Methods: Radiation dose structured reports were retrospectively collected for 408 clinical pediatric cases: Half of the procedures were performed with a standard imaging technology and half with a novel x-ray technology. Dose-area product (DAP), air Kerma (AK), fluoroscopy time, number of digital subtraction angiography images, and patient mass were collected to calculate and normalize radiation dose indexes for procedures completed with the standard and novel fluoroscopes.
Objective: This article reviews the concepts of CT radiation dose optimization and process control, discusses how to achieve optimization and how to verify that it is consistently accomplished, and proposes strategies to move toward large-scale application.
Conclusion: CT dose optimization is achieved when the least amount of radiation necessary is used to achieve adequate image quality. The key to consistent optimization is minimization of unnecessary variation.
Objective: The purpose of this study was to develop a departmental practice quality improvement project to systematically reduce CT doses for the evaluation of suspected pediatric appendicitis by introducing computer-generated gaussian noise.
Materials And Methods: Two hundred MDCT abdominopelvic examinations of patients younger than 20 years performed with girth-based scanning parameters for suspected appendicitis were reviewed. Two judges selected 45 examinations in which the diagnosis of appendicitis was excluded (14, appendix not visualized; 31, normal appendix visualized).
This paper discusses the merits and weaknesses of the standard terms that have been developed to quantify CT dose: CT dose indices (CTDI), dose length product (DLP) and effective dose. The difference between the measured CTDIvol and the CTDIvol displayed on the CT scanner illustrates a clinical dilemma. Displayed CTDIvol represents the radiation dose delivered to a plastic phantom, which is significantly different from the dose delivered to the patient, depending on the size of the patient.