Phys Rev Lett
February 2024
Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion.
View Article and Find Full Text PDFIn many inertial confinement fusion (ICF) experiments, the neutron yield and other parameters cannot be completely accounted for with one and two dimensional models. This discrepancy suggests that there are three dimensional effects that may be significant. Sources of these effects include defects in the shells and defects in shell interfaces, the fill tube of the capsule, and the joint feature in double shell targets.
View Article and Find Full Text PDFIn the Double Shell Inertial Confinement Fusion concept, characterizing the shape asymmetry of imploding metal shells is vital for understanding energy-efficient compression and radiative losses of the thermonuclear fuel. The Monte Carlo N-Particle MCNP code forward models radiography of Double Shell capsule implosions using the Advanced Radiographic Capability at the National Ignition Facility. A procedure is developed for using MCNP to reconstruct density profiles from the radiograph image intensity.
View Article and Find Full Text PDFIn inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired.
View Article and Find Full Text PDFA Talbot-Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 cm by means of Moiré deflectometry. The experiment used a short-pulse laser (30-100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described.
View Article and Find Full Text PDFThe creation and disruption of inertially collimated plasma flows are investigated through experiment, simulation, and analytical modeling. Supersonic plasma jets are generated by laser-irradiated plastic cones and characterized by optical interferometry measurements. Targets are magnetized with a tunable B field with strengths of up to 5 T directed along the axis of jet propagation.
View Article and Find Full Text PDFWe present an experimental design for a radiation hydrodynamics experiment at the National Ignition Facility that measures the electron temperature of a shocked region using the x-ray Thomson scattering technique. Previous National Ignition Facility experiments indicate a reduction in Rayleigh-Taylor instability growth due to high energy fluxes, compared to the shocked energy flux, from radiation and electron heat conduction. In order to better quantify the effects of these energy fluxes, we modified the previous experiment to allow for non-collective x-ray Thomson scattering to measure the electron temperature.
View Article and Find Full Text PDFThis paper examines the experimental requirements to observe two shock fronts driven by a single x-ray source in systems with a sharp absorption edge. We consider systems where the peak of the x-ray radiation drive coincides with the K-edge of the carbon, which occurs at a photon energy of 284 eV, causing photons to be deposited in two regions. The low-energy photons (E < 284 eV) penetrate further and drive the main shock, while the higher-energy photons (E > 284 eV) are absorbed in the ablated plasma.
View Article and Find Full Text PDFBacklit-pinhole radiography uses a pinhole placed between an x-ray source and a sample. The backlit-multi-pinhole design uses two pinholes on the same substrate, which are separated by a wall, to create two radiographic images projected along similar axes. The wall, a 100-m thick titanium foil, prevents x-rays generated near one pinhole from exiting the other pinhole.
View Article and Find Full Text PDFThe properties of hot, dense plasmas generated by the irradiation of GaAs targets by the Titan laser at Lawrence Livermore National Laboratory were determined by the analysis of high resolution K shell spectra in the 9 keV to 11 keV range. The laser parameters, such as relatively long pulse duration and large focal spot, were chosen to produce a steady-state plasma with minimal edge gradients, and the time-integrated spectra were compared to non-LTE steady state spectrum simulations using the FLYCHK and NOMAD codes. The bulk plasma streaming velocity was measured from the energy shifts of the Ga He-like transitions and Li-like dielectronic satellites.
View Article and Find Full Text PDFA new approach for the spectral reconstruction of time-dependent emission of soft x-ray sources based on the measurement of filtered x-ray diode array systems is suggested. Two reconstruction methods, based on this approach, are demonstrated using both simulated and measured data. The methods use the filtered x-ray diode measurement together with a co-aligned, time-integrated, spectrally resolved measurement, such as transmission grating spectroscopy.
View Article and Find Full Text PDFExperiments were performed to mitigate the hard x-ray background commonly observed in backlit pinhole imagers. The material of the scaffold holding the primary backlighter foil was varied to reduce the laser-plasma instabilities responsible for hot electrons and resulting hard x-ray background. Radiographic measurements with image plates showed a factor of >25 decrease in x-rays between 30 and 67 keV when going from a plastic to Al or V scaffold.
View Article and Find Full Text PDFRev Sci Instrum
November 2016
Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies [J. F. Hansen et al.
View Article and Find Full Text PDFRev Sci Instrum
November 2016
Soft x-ray emission from laser irradiated gold foils was measured at the Omega-60 laser system using the Dante photodiode array. The foils were heated with 2 kJ, 6 ns laser pulses and foil thicknesses were varied between 0.5, 1.
View Article and Find Full Text PDFFoams are a common material for high-energy-density physics experiments because of low, tunable densities, and being machinable. Simulating these experiments can be difficult because the equation of state is largely unknown for shocked foams. The focus of this experiment was to develop an x-ray scattering platform for measuring the equation of state of shocked foams on OMEGA EP.
View Article and Find Full Text PDFWe measured the stopping of energetic protons in an isochorically heated solid-density Be plasma with an electron temperature of ∼32 eV, corresponding to moderately coupled [(e^{2}/a)/(k_{B}T_{e}+E_{F})∼0.3] and moderately degenerate [k_{B}T_{e}/E_{F}∼2] "warm-dense matter" (WDM) conditions. We present the first high-accuracy measurements of charged-particle energy loss through dense plasma, which shows an increased loss relative to cold matter, consistent with a reduced mean ionization potential.
View Article and Find Full Text PDFCreating magnetized jets in the laboratory is relevant to studying young stellar objects, but generating these types of plasmas within the laboratory setting has proven to be challenging. Here, we present the construction of a solenoid designed to produce an axial magnetic field with strengths in the gap of up to 5 T. This novel design was a compact 75 mm × 63 mm × 88 mm, allowing it to be placed in the Titan target chamber.
View Article and Find Full Text PDFRev Sci Instrum
November 2014
Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-α x-ray source.
View Article and Find Full Text PDFRev Sci Instrum
November 2014
Experiments at the Trident Laser Facility have successfully demonstrated the use of x-ray fluorescence imaging (XRFI) to diagnose shocked carbonized resorcinol formaldehyde (CRF) foams doped with Ti. One laser beam created a shock wave in the doped foam. A second laser beam produced a flux of vanadium He-α x-rays, which in turn induced Ti K-shell fluorescence within the foam.
View Article and Find Full Text PDFTurbulent mixing of two fluid species is a ubiquitous problem, prevalent in systems such as inertial confinement fusion (ICF) capsule implosions, supernova remnants, and other astrophysical systems. In complex, high Reynolds number compressible high energy density (HED) flows such as these, hydrodynamic instabilities initiate the turbulent mixing process, which can then feedback and alter the mean hydrodynamic motion through nonlinear processes. In order to predict how these systems evolve under turbulent conditions, models are used.
View Article and Find Full Text PDFBacklit pinhole x-ray radiography has provided high-resolution images in many recent high-energy-density laser experiments. Its aim is to image the object of interest with a roughly monochromatic Kα source. However, despite the high intrinsic brightness achieved by the technique, data on x-ray film have shown a signal to background ratio near one, with data on image plates producing a higher background.
View Article and Find Full Text PDFIn many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas.
View Article and Find Full Text PDFWe present a technique for measuring the propagation of a supersonic radiation front in low-density foam, where the lack of motion of the objects in its wake makes it difficult to determine its location. We illuminate a thin tracer foil embedded in the foam with a broadband x-ray source, and measure its changing absorption of these x rays as it ionizes. We record both spatial and spectral information of the heated tracer, and thus obtain its ionization state as a function of distance along the front propagation direction.
View Article and Find Full Text PDF