Publications by authors named "Kazui T"

The United Network for Organ Sharing (UNOS) heart transplant allocation policy was changed in 2018. This study examines the impact of the change in UNOS heart transplant allocation policy on the use of temporary mechanical circulatory support (MCS) devices and post-transplant survival. The analysis included a total of 26,481 patients listed and transplanted between January 2013 and June 2022.

View Article and Find Full Text PDF

Introduction And Importance: Society of thoracic surgery (STS) risk score has been used as a tool to gauge operative risk of cardiac surgery patients. High-risk patients, with STS risk score > 8 %, are considered as having prohibitive risk and are not offered surgery. There is no established strategy to minimize postoperative hemodynamic instability using mechanical circulatory support (MCS), despite growing interest in utilizing MCS prior to hemodynamic instability.

View Article and Find Full Text PDF

Purpose Of Review: Cardiac Allograft vasculopathy (CAV) is a major barrier to improving outcomes after heart transplantation. Coronary angiography has very low sensitivity to detect early CAV and intravascular ultrasound (IVUS) only improves it to some extent. In this article, we detail the current evidence surrounding use of Optical Coherence tomography (OCT) in patients with CAV.

View Article and Find Full Text PDF

Background: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a key support modality for cardiogenic shock. The 2018 United Network for Organ Sharing (UNOS) heart transplant allocation algorithm prioritizes VA-ECMO patients.

Objective: To evaluate the role of VA-ECMO in bridging to advanced heart failure therapies.

View Article and Find Full Text PDF

Aortic valve disorders are important considerations in advanced heart failure patients being evaluated for left ventricular assist devices (LVAD) and those on LVAD support. Aortic insufficiency (AI) can be present prior to LVAD implantation or develop during LVAD support. It is usually a progressive disorder and can lead to impaired LVAD effectiveness and heart failure symptoms.

View Article and Find Full Text PDF

Objective: The purpose of this study is to assess whether the 5-m walk test is associated with 1-year mortality after transcatheter aortic valve replacement.

Methods: Included in the analysis were 304 patients who received the 5-m walk test and underwent transcatheter aortic valve replacement from September 2012 to March 2019. They were classified into 3 groups based on their test score: ≤7, >7, and unable to walk.

View Article and Find Full Text PDF

Our study assessed the relationship between the duration of venovenous extracorporeal membrane oxygenation (V-V ECMO) and patient outcomes. We studied patients undergoing V-V ECMO support for acute respiratory distress syndrome (ARDS) between 2009 and 2017 who were reported to the Extracorporeal Life Support Organization registry. We evaluated survival, major bleeding, renal failure, pulmonary complications, mechanical complications, neurologic complications, infection, and duration of V-V ECMO support.

View Article and Find Full Text PDF

Severe congenital Factor XI (FXI) deficiency (<20% normal activity) can be associated with significant bleeding disorders, and there has been great concern for severe bleeding following cardiac surgery requiring cardiopulmonary bypass (CPB) in this patient population. Over the past four decades remarkably different approaches to this problem have been taken, including the administration of blood volumes of fresh frozen plasma, administration of activated recombinant Factor VII, and diminutive administration of heparin. We describe a case wherein the patient was assessed in the perioperative period with a point-of-care, viscoelastic hemostasis device (ROTEM), with changes in the intrinsic/Factor XII-dependent coagulation pathway determined before, during, and after CPB.

View Article and Find Full Text PDF

Thrombocytosis has been feared as a source of thrombotic complications during the conduct of cardiopulmonary bypass (CPB) for patients undergoing cardiac procedures. We present a patient urgently requiring repair/replacement of three heart valves that had preexisting myelofibrosis with thrombocytosis (platelet count of 800,000 per µl) and neutrophilia (40,000 per µl). Despite achieving an activated clotting time > 500 s with heparin and antithrombin concentrate administration prior to CPB, the pump oxygenator and reservoir demonstrated significant clot just prior to restoration of the patient's circulation.

View Article and Find Full Text PDF

The pathogenicity of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has been attributed to its ability to enter through the membrane-bound angiotensin-converting enzyme 2 (ACE2) receptor. Therefore, it has been heavily speculated that angiotensin-converting enzyme inhibitor (ACEI) or angiotensin receptor blocker (ARB) therapy may modulate SARS-CoV-2 infection. In this study, exposure of human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) and human endothelial cells (hECs) to SARS-CoV-2 identified significant differences in protein coding genes involved in immunity, viral response, and cardiomyocyte/endothelial structure.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement within a degenerated surgical bioprosthetic aortic valve is increasing in frequency. We present a rare case of a patient requiring a second TAVR placed within a previous placed degenerated transcatheter aortic valve, which was implanted in a degenerated surgical bioprosthetic aortic valve. ().

View Article and Find Full Text PDF

Left ventricular assist devices (LVAD) have revolutionized the management of advanced heart failure. However, complications rates remain high, among which hemorrhagic and thrombotic complications are the most important. Antiplatelet and anticoagulation strategies form a cornerstone of LVAD management and may directly affect LVAD complications.

View Article and Find Full Text PDF

This study compares the morbidity and mortality at 30 days following the use of bilateral internal mammary arteries (BIMA) vs a single internal mammary artery (SIMA) at the time of coronary artery bypass grafting (CABG) in patients with a preoperative HbA1c. Patients undergoing CABG from January 2008 to December 2016 reported to the Society of Thoracic Surgeons database were retrospectively reviewed. The patients were divided into 2 groups: use of BIMA or use of SIMA and propensity matched.

View Article and Find Full Text PDF

Background: The purpose of this study was to identify predictors of mortality and potentially modifiable factors related to arrhythmias in patients that undergo transcatheter aortic valve replacement (TAVR). Patients that undergo TAVR are at risk for complete heart block requiring pacemaker implant. Additionally, other arrhythmias, specifically atrial fibrillation (AF), are common in this population.

View Article and Find Full Text PDF

Thrombosis within the membrane oxygenator (MO) during extracorporeal membrane oxygenation (ECMO) can lead to sudden oxygenator dysfunction with deleterious effects to the patient. The purpose of this study was to identify predictors of circuit exchange during ECMO. This is a single-center, retrospective study of all patients who received ECMO at our institution from January 2010 to December 2015.

View Article and Find Full Text PDF

We report a case of coronary sinus (CS) injury with a retrograde cardioplegia catheter and repair that compromised CS patency. This resulted in acute global cardiac dysfunction shortly after weaning from bypass, which reversed after patch repair with confirmed CS patency. The case report shows that acute CS occlusion may not be tolerated in some humans.

View Article and Find Full Text PDF

Maintaining mechanical circulatory support (MCS) device patients in a specified therapeutic range for anticoagulation remains challenging. Subtherapeutic international normalized ratios (INRs) occur frequently while on warfarin therapy. An effective anticoagulant bridge strategy may improve the care of these patients.

View Article and Find Full Text PDF

Mitral valve repair is a feasible and preferable option for the treatment of Barlow's disease. Complex valve repair techniques, in contrast, often lead to increased cross-clamp times and low cardiac output syndrome. A simple, fast, and reproducible foldoplasty technique to reduce anterior and posterior mitral leaflet heights may improve coaptation and reduce mitral regurgitation.

View Article and Find Full Text PDF

Background: Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively.

View Article and Find Full Text PDF

Background: Temporary mechanical circulatory support device without sternotomy has been highly advocated for severe cardiogenic shock patient but little is known when coupled with amniotic stem cell therapy.

Case Presentation: This case reports the first dual therapy of temporary left ventricular extracorporeal device CentriMag with distal banding technique and human amniotic stem cell injection for treating a severe refractory cardiogenic shock of an 68-year-old female patient. A minimally-invasive off-pump LVAD was established by draining from the left ventricle and returning to the right axillary artery with distal arterial banding to prevent right upper extremity hyperperfusion.

View Article and Find Full Text PDF

CorMatrix is an organic extracellular matrix (ECM) derived from porcine small intestine submucosa and is used for pericardial closure and cardiac tissue repair. During explantation of a HeartMate II (Thoratec Corp, Pleasanton, CA) left ventricular assist device (LVAD) because of infection, CorMatrix was used to repair the left ventricular apex and aorta. Three months later, a HeartWare HVAD (HeartWare International, Inc, Framingham, MA) was implanted for recurrent heart failure.

View Article and Find Full Text PDF

Background: Cardiomyocytes rely heavily on mitochondrial energy production through oxidative phosphorylation. Chronic myocardial ischemia may cause mitochondrial dysfunction and affect ATP formation. Metabolic changes due to ischemia alters cardiac bioenergetics and hence myocardial function and overall bioenergetic state.

View Article and Find Full Text PDF

Heparin-induced thrombocytopenia (HIT) is an immune reaction usually secondary to unfractionated heparin. Anticoagulation management is critical in patients while on extracorporeal membrane oxygenation (ECMO) to prevent thromboembolism and for the optimal functioning of the circuit. We identified five patients with respiratory failure at our hospital managed with ECMO in the last 2 years that were treated for HIT.

View Article and Find Full Text PDF