Publications by authors named "Kazuhiro Murotani"

Study Design: A retrospective multicenter case series was conducted.

Purpose: This study aimed to investigate survival and prognostic factors after surgery for a metastatic spinal tumor.

Overview Of Literature: Prognostic factors after spinal metastasis surgery remain controversial.

View Article and Find Full Text PDF

Objective: This study aimed to clarify the effect of embolization with lipiodol on portal vein hemodynamics.

Methods: Time-density curves of the main portal vein on multilevel dynamic multidetector computed tomography during arterial portography were used to analyze peak computed tomography value (PV), time to PV (TPV), arrival time of contrast medium at the main portal vein (ATMPV), slope [(PV - 150) / (TPV - ATMPV)], and slope ratio (slope after embolization / slope before embolization).

Results: In 20 patients with hepatoma, ATMPV and TPV were significantly prolonged and the time-density curve slope was significantly less after embolization.

View Article and Find Full Text PDF

We describe an 85-year-old man suffering lower urinary tract symptoms, who underwent prostatic artery embolization (PAE) based on a prostate-supplying arteriogram created with multidetector-row computed tomography during pelvic arteriography. This arteriogram was synthesized from a background bone volume-rendered (VR) image, an aorta-pelvic artery VR image, and a prostate-supplying artery VR image. Because the bone background VR image is combined with the aorta-pelvic artery VR image, the prostate-supplying arteriogram can simultaneously show the pelvic branch arteries present on the ventral side, inside, and the dorsal side of the pelvic bone.

View Article and Find Full Text PDF

Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation.

View Article and Find Full Text PDF

Purpose: To compare air kerma after scanning a phantom with C-arm CT and with 64-multidetector row CT (64MDCT).

Materials And Methods: A phantom was scanned using parameters based on data of ten patients with hepatocellular carcinoma who had C-arm CT during hepatic arteriography and 64MDCT during arterial portography. Radiation monitors were used to measure air kerma ten times at each of five points: the center (A), top (B), left side (C), bottom (D), and right side (E).

View Article and Find Full Text PDF

Scanning timing for multi-detector row computed tomography during thoracic aortography (MDCT-TA) was explored for depiction of arteries responsible for hemoptysis. The mean time (MT) from contrast medium (CM) injection to peak enhancement (PE) in the descending aorta at the level of the diaphragm on thoracic aortography was investigated. The MT to PE of the descending aorta at the level of diaphragm was 4.

View Article and Find Full Text PDF

CT during aortography (CTAo) using IVR 64-multidetector-row CT (IVR-64MDCT) enables the rapid and simultaneous depiction of both the hepatic and extrahepatic feeding arteries in hepatocellular carcinoma (HCC), and can be achieved using a reasonable volume of contrast medium. The scan time is approximately 6 s from the diaphragm to the kidney using CTAo with 64MDCT with a slice thickness and slice interval of 0.5 mm.

View Article and Find Full Text PDF

We quantified to clarify the optimum factors for CT image reconstruction of an enhanced hepatocellular carcinoma (HCC) model in a liver phantom obtained by multi-level dynamic computed tomography (M-LDCT) with 64 detector rows. After M-LDCT scanning of a water phantom and an enhanced HCC model, we compared the standard deviation (SD, 1 ± SD), noise power spectrum (NPS) values, contrast-noise ratios (CNR), and the M-LDCT image among the reconstruction parameters, including the convolution kernel (FC11, FC13, and FC15), post-processing quantum filters (2D-Q00, 2D-Q01, and 2D-Q02) and slice thicknesses/slice intervals. The SD and NPS values were lowest with FC11 and 2D-Q02.

View Article and Find Full Text PDF

This study aimed to identify the optimal concentration, injection rate, and total volume of contrast medium (CM) for evaluating the hemodynamics of a hepatocellular carcinoma (HCC) structure model of diameter 35 mm, using multi-level dynamic computed tomography (M-LDCT) with 64 detector rows. A tube was inserted in the model as a simulated vessel. Five CM concentrations were used: non-diluted, 2-, 3-, 6-, and 9-fold diluted.

View Article and Find Full Text PDF