Background: The Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) showed that early intervention with cardiac-resynchronization therapy with a defibrillator (CRT-D) in patients with an electrocardiographic pattern showing left bundle-branch block was associated with a significant reduction in heart-failure events over a median follow-up of 2.4 years, as compared with defibrillator therapy alone.
Methods: We evaluated the effect of CRT-D on long-term survival in the MADIT-CRT population.
Background: Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker.
Methods And Results: The primary safety end point was freedom from complications at 90 days.
Objectives: The purpose of this study was to compare the prognostic impact of clinical and biomarker correlates of resting heart rate (HR) and chronotropic incompetence in heart failure (HF) patients.
Background: The mechanisms and underlying pathophysiological influences of HR abnormalities in HF are incompletely understood.
Methods: In a prospective pilot study, 81 patients with advanced systolic HF (97% were receiving beta-blockers) and 25 age-, sex-, and body-size matched healthy controls underwent maximal cardiopulmonary exercise testing with sampling of neurohormones and biomarkers.
Aims: The Atrial Fibrillation Ablation Pilot Study is a prospective registry designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation, and the diagnostic/therapeutic processes applied across Europe. The aims of the 1-year follow-up were to analyse how centres assess in routine clinical practice the success of the procedure and to evaluate the success rate and long-term safety/complications.
Methods And Results: Seventy-two centres in 10 European countries were asked to enrol 20 consecutive patients undergoing a first AFib ablation procedure.
Background: Diffusion-weighted magnetic resonance imaging (DW-MRI) is a widely used method for studying of asymptomatic brain injury during catheter ablation of atrial fibrillation (AF). However, this technique lacks sensitivity for subtle or diffuse brain lesions. We investigated whether detection of the ablation-related brain injury can improve by assessment of a biomarker of brain damage-protein S100B.
View Article and Find Full Text PDFArrhythm Electrophysiol Rev
November 2013
Recently, catheter ablation (CA) has become a therapeutic option to target focal triggers of polymorphic ventricular tachycardia and ventricular fibrillation (VF) in the setting of electrical storm (ES). This strategy was first described in subjects without organic heart disease (i.e.
View Article and Find Full Text PDFBackground: Hypertrophic cardiomyopathy with severe left ventricular diastolic dysfunction has been associated with marked exercise intolerance and poor prognosis. However, molecular pathogenesis of this phenotype remains unexplained in a large proportion of cases.
Methods And Results: We performed whole exome sequencing as an initial genetic test in a large Czech family with 3 males affected by nonobstructive hypertrophic cardiomyopathy with severe left ventricular diastolic dysfunction in end-stage disease.
Clinical data on optimal management of mechanical complications of myocardial infarction are lacking. We retrospectively evaluated the effect of intra-aortic balloon pump (IABP) on 30-day survival in patients with postinfarction ventricular septal rupture (VSR, n = 55) or acute mitral regurgitation (MR, n = 26) who developed either cardiogenic shock (n = 46) or severe hemodynamic instability that did not fulfill the criteria of shock (n = 35). IABP was inserted in 83% of the patients with shock and 57% of those without shock.
View Article and Find Full Text PDFObjectives: This study sought to examine the relationships between right ventricular (RV) function, body composition, and prognosis in patients with advanced heart failure (HF).
Background: Previous studies investigating HF-related cachexia have not examined the impact of RV function on body composition. We hypothesized that RV dysfunction is linked to weight loss, abnormal body composition, and worsened prognosis in advanced HF.
Background: During radiofrequency ablation, high electrode-tissue contact force (CF) is associated with increased risk of steam pop and perforation. The purpose of this study, in patients undergoing ablation of paroxysmal atrial fibrillation, was to: (1) identify factors producing high CF during left atrial (LA) and pulmonary vein mapping; (2) determine the ability of atrial potential amplitude and impedance to predict CF; and (3) explore the feasibility of controlling radiofrequency power based on CF.
Methods And Results: A high-density map of LA/pulmonary veins (median 328 sites) was obtained in 18 patients undergoing atrial fibrillation ablation using a 7.
Objectives: PTOLEMY-2 was a prospective multicenter phase I single-arm feasibility trial to evaluate the second-generation permanent percutaneous transvenous mitral annuloplasty (PTMA) device in reducing functional mitral regurgitation (MR).
Background: Percutaneous MR reduction has been performed through a direct method of clipping and securing the mitral leaflets together or an indirect approach of reducing mitral annular dimension via the coronary sinus. The PTMA device is the only coronary sinus mitral repair device without a static fixation element.
Aims: Right ventricular apical pacing has a detrimental effect on left ventricular (LV) function. More optimal pacing site may be found by invasive measurement of LV mechanical performance during pacing from different RV pacing sites. We aimed to investigate the effect of RV pacing lead location on invasive indices of LV mechanical performance.
View Article and Find Full Text PDFRecent Pat Cardiovasc Drug Discov
April 2013
Radiofrequency catheter ablation without active cooling of the catheter tip is associated with significantly increased risk of thrombus formation and thromboembolism, especially when multiple and high-energy deliveries are considered. Therefore, irrigation of the distal electrode has become obligatory for catheter ablation of complex cardiac arrhythmias. The advancement in the cooling catheter technology is aimed to further reduce the risk of steam pop as well as coagulum formation on both electrode and tissue, and to maximize energy transfer to the tissue.
View Article and Find Full Text PDFBackground: Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to perform point-to-point circumferential ablation. Single-center studies have demonstrated favorable safety and efficacy.
View Article and Find Full Text PDFBackground: Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up.
View Article and Find Full Text PDFPurpose: Cavotricuspid isthmus-dependent atrial flutter (AFL) can occur in a paroxysmal or persistent pattern. The aim of this study was to identify clinical, echocardiographic, and electrophysiological risk factors independently associated with persistence of AFL.
Methods: Patients of the recently published AURUM 8 study with paroxysmal versus persistent AFL were compared with respect to clinical and echocardiographic baseline characteristics as well as procedural parameters.
Background: In the Ventricular Tachycardia Ablation in Coronary Heart Disease (VTACH) study, an intention-to-treat approach was used and may have diminished the observed degree of treatment effect. We present a subanalysis of the VTACH study by treatment actually received.
Methods And Results: The VTACH study was a prospective, open, randomized controlled trial, undertaken in 16 European centers, comparing defibrillator implantation with and without ventricular tachycardia (VT) ablation in patients with stable VT, previous myocardial infarction, and reduced left-ventricular ejection fraction.
Objectives: This study aimed to evaluate the performance of cardiac magnetic resonance (CMR), cardiac biomarkers, and endomyocardial biopsy (EMB) results to predict left ventricular reverse remodeling (LVRR) in individuals with recent-onset dilated cardiomyopathy (DCM).
Background: LVRR is a marker of a favorable prognosis in individuals with recent-onset DCM. We used the aforementioned novel methods of prognostication to predict this event.
Expert Rev Med Devices
November 2012
Background: The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects.
Methods: We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.
We evaluated the clinical utility of cardiac magnetic resonance imaging (CMR) combined with a novel high-sensitivity troponin T assay (hs-cTnT) in the diagnosis of inflammatory cardiomyopathy. CMR, measurement of hs-cTnT, and endomyocardial biopsy were performed in 42 patients with dilated cardiomyopathy and a short-term history of heart failure (median 2 months, interquartile range 1 to 3.5).
View Article and Find Full Text PDFBackground: The goal was to examine the hemodynamic and clinical effects of long-term therapy with PDE5 inhibitor sildenafil (SILD) in patients with advanced, pre-transplant heart failure (HF) and severe pulmonary hypertension (PH), in comparison to a similar control group (CON).
Methods: In this non-randomized, retrospective case-control study, 32 middle-aged patients (81% males) with advanced systolic HF (80%≥ NYHA III, 56% ischemic) and severe pre-capillary PH (transpulmonary pressure gradient>15 mm Hg) were studied before and after initiation of SILD (dose 73 ± 25 mg/day) and were compared to 15 CON patients, matched for key clinical characteristics (including PH severity, age and co-morbidities), not exposed to SILD. Changes at 3 months and the long-term outcome were compared between groups.
Aims: Catheter ablation (CA) for atrial fibrillation (AF) is a complex procedure that is associated with higher risk of complications. This study aimed at exploring the complication rate and corresponding risk factors in a high-volume centre with routine use of intracardiac echocardiography (ICE).
Methods And Results: In total 1192 consecutive AF ablation procedures (100% ICE-guided; 96.
Defibrillation testing (DT) has been an integral part of defibrillator (implantable cardioverter defibrillator [ICD]) implantation; however, there is little evidence that it improves outcomes. Surveys show a trend toward ICD implantation without DT, which now exceeds 30% to 60% in some regions. Because there is no evidence to support dramatic shift in practice, a randomized trial is urgently needed.
View Article and Find Full Text PDF