Objective: To investigate the haemodynamic effects of gamma-hydroxybutyric acid (GHB) in isoflurane-anaesthetized pigs.
Study Design: Experimental, randomized, nonblinded, crossover study.
Animals: A group of six stress-resistant Landrace pigs (approximately 3 months old; three male, three female; bodyweight 39.
Background: In previous publications, the Task Force on Reference Measurement System Implementation proposed a procedural approach combining a critical review of entries available in the Joint Committee on Traceability in Laboratory Medicine (JCTLM) database with a comparison of this information against analytical performance specifications for measurement uncertainty (MU) and applied it to a group of 13 measurands.
Content: Here we applied this approach to 17 additional measurands, of which measurements are frequently requested. The aims of the study were (a) to describe the main characteristics for implementing traceability and the potential to fulfill the maximum allowable MU (MAU) at the clinical sample level of certified reference materials and reference measurement procedures listed in the JCTLM database; (b) to discuss limitations and obstacles, if any, to the achievement of the required quality of laboratory measurements; and (c) to provide a gap analysis by highlighting what is still missing in the database.
Blood microsampling has increasingly attracted interest in the past decades as a more patient-centric sampling approach, offering the possibility to collect a minimal volume of blood following a finger or arm prick at home. In addition to conventional dried blood spots (DBS), many different devices allowing self-sampling of blood have become available. Obviously, the success of home-sampling can only be assured when (inexperienced) users collect samples of good quality.
View Article and Find Full Text PDFThyroid-stimulating hormone (TSH) is an important clinical marker in the diagnosis and management of thyroid disease. TSH measurements are reported in milli-International Units per Litre (mIU/L), traceable to a World Health Organisation (WHO) reference material. There is a wide variety of commercial immunoassays for TSH measurements available, which have historically been poorly harmonised due to a lack of commutability of the WHO reference materials with patient samples.
View Article and Find Full Text PDFSedative as well as protective effects during hypoxia have been described for gamma-hydroxybutyric acid (GHB). Six swine (Sus scrofa domesticus) of 6 weeks old were administered NaGHB at a dose of 500 mg/kg intravenously (IV) and 500 and 750 mg/kg orally (PO) in a triple cross-over design. Repeated blood sampling was performed to allow pharmacokinetic analysis of GHB.
View Article and Find Full Text PDFDespite being the most performed laboratory endocrine investigation, the optimum use of thyroid tests (thyrotropin [TSH] and thyroid hormone [TH] measurement) is open to question and the interpretation of the results from these tests can be ambiguous. The American Thyroid Association (ATA) with its expertise support the endeavor of the U.S.
View Article and Find Full Text PDFThe rapidly evolving synthetic cannabinoid receptor agonist (SCRA) market poses significant challenges for forensic scientists. Since the enactment of a generic ban in China, a variety of new compounds have emerged capable of evading the legislation by carrying new structural features. One recent example of a SCRA with new linker and head moieties is CH-PIATA (CH-PIACA, CHX-PIATA, CHX-PIACA).
View Article and Find Full Text PDFJ Mass Spectrom Adv Clin Lab
August 2023
Background: Free thyroxine (FT4) measurement is one of the most requested tests in patient care for diagnosing and treating thyroid-related illnesses. Equilibrium dialysis (ED) is considered the "gold standard" for FT4 measurement; however, several factors have a profound effect on the reliability of FT4 assays and require special consideration.
Methods: In the current study, we focused on evaluating critical factors that could contribute to reporting errors, such as adsorption of thyroxine (T4) to labware surfaces, stability of serum samples, stock solutions, and calibrator storage conditions, as well as the solvents used to prepare T4 solutions.
Objectives: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists.
View Article and Find Full Text PDFBackground: Accurate and reliable measurement of human serum free thyroxine (FT4) is critical for the diagnosis and treatment of thyroid diseases. However, concerns have been raised regarding the performance of FT4 measurements in patient care. Centers for Disease Control and Prevention Clinical Standardization Programs (CDC-CSP) address these concerns by creating a FT4 standardization program to standardize FT4 measurements.
View Article and Find Full Text PDFIn recent years, a lot of attention has been given to a more patient-centric therapeutic drug monitoring (TDM) of immunosuppressant drugs (tacrolimus, sirolimus, everolimus and cyclosporin A) by the use of microsampling techniques. By adopting Dried Blood Spots (DBS) after a finger prick, instead of conventional venous blood draws, follow-up can (partially) be established from patients' homes. Despite the many advantages of DBS, one of the major disadvantages associated with this technique is the well described hematocrit (hct) effect.
View Article and Find Full Text PDFThe pandemic readiness toolbox needs to be extended, targeting different biomolecules, using orthogonal experimental set-ups. Here, we build on our Cov-MS effort using LC-MS, adding SISCAPA technology to enrich proteotypic peptides of the SARS-CoV-2 nucleocapsid (N) protein from trypsin-digested patient samples. The CovMS assay is compatible with most matrices including nasopharyngeal swabs, saliva, and plasma and has increased sensitivity into the attomole range, a 1000-fold improvement compared to direct detection in a matrix.
View Article and Find Full Text PDFDrug Test Anal
October 2022
Following the class-wide ban of synthetic cannabinoid receptor agonists (SCRAs) in China, SCRAs carrying new core and linker structures, aimed at circumventing the recent Chinese generic legislation, have appeared on the recreational drug market. A very recent example is (S)-2-(2-(1-(4-fluorobenzyl)-1H-indol-3-yl)acetamido)-3,3-dimethylbutanamide (ADB-FUBIATA), which is structurally closely related to the potent SCRA ADB-FUBICA, but carries an additional methylene in the linker region of the molecule. ADB-FUBIATA has recently been identified in seized materials in China, Russia, the United States, and also Belgium; however, its pharmacological characteristics were unknown.
View Article and Find Full Text PDFIn recent years, several nations have implemented various measures to control the surge of new synthetic cannabinoid receptor agonists (SCRAs) entering the recreational drug market. In July 2021, China put into effect a new generic legislation, banning SCRAs containing one of seven general core scaffolds. However, this has driven manufacturers towards the synthesis of SCRAs with alternative core structures, exemplified by the recent emergence of "OXIZID SCRAs.
View Article and Find Full Text PDFBackground: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community.
Content: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined.
Summary: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU.
Rising population density and global mobility are among the reasons why pathogens such as SARS-CoV-2, the virus that causes COVID-19, spread so rapidly across the globe. The policy response to such pandemics will always have to include accurate monitoring of the spread, as this provides one of the few alternatives to total lockdown. However, COVID-19 diagnosis is currently performed almost exclusively by reverse transcription polymerase chain reaction (RT-PCR).
View Article and Find Full Text PDFSome subgroups dominate on healthy skin, whereas others are frequently acne associated. Here we provide mechanistic insights into this difference, using an anaerobic keratinocyte-sebocyte- co-culture model. An acneic strain as well as its porphyrins activates NRLP3 inflammasome assembly, whereas this was not observed with a non-acneic strain.
View Article and Find Full Text PDFSeveral 2-benzylbenzimidazole opioids (also referred to as "nitazenes") recently emerged on the illicit market. The most frequently encountered member, isotonitazene, has been identified in multiple fatalities since its appearance in 2019. Although recent scheduling efforts targeted isotonitazene, many other analogues remain unregulated.
View Article and Find Full Text PDFBackground: Stimulated by the increased recognition of phosphatidylethanol (PEth) as sensitive direct marker of alcohol intake, the Ghent University's Laboratory of Toxicology and the National Institute of Criminalistics and Criminology combined their efforts to develop a quantitative method. To facilitate implementation the focus was on the use of a sampling technique which allows quick and easy blood collection, without the need of dedicated personnel at any place/any time. In the meantime the cooperation of the two labs should also allow to initiate a Belgian network of laboratories capable of quantifying PEth.
View Article and Find Full Text PDF