Publications by authors named "Katia Menacho"

Background: Isolated left ventricular apical hypoplasia (ILVAH) is a rare, probably congenital, cardiac condition recently reported in the last two decades. Although most cases are asymptomatic or mildly symptomatic, some severe and fatal cases have been reported, leading to more efforts for appropriate diagnosis and treatment. We describe the first, and severe, case of this pathology in Peru and Latin America.

View Article and Find Full Text PDF
Article Synopsis
  • A study analyzed the plasma proteome of 156 healthcare workers in the UK who had SARS-CoV-2 infections during the first wave, focusing on the relationship between the plasma proteins and the severity/duration of symptoms.
  • The researchers tracked 91 specific proteins before and after infection, finding that changes in the plasma proteome lasted up to 6 weeks post-infection and were linked to symptom severity and antibody responses.
  • Results indicated that specific protein changes were associated with persistent symptoms even 12 months later, suggesting these plasma proteome alterations could help understand the long-term effects of COVID-19.
View Article and Find Full Text PDF
Article Synopsis
  • The Omicron variant (B.1.1.529) of SARS-CoV-2 has many mutations that make it highly transmissible and partially able to evade neutralizing antibodies, but vaccinated individuals still have some protection against severe disease due to strong cellular immunity.
  • In a study involving healthcare workers who received three doses of the BioNTech mRNA vaccine, it was found that their B and T cell responses were enhanced against older variants but less effective against the Omicron spike protein.
  • Those previously infected with earlier variants (like Alpha) had reduced antibody responses against Omicron, while uninfected individuals who got infected with Omicron showed improved immunity to earlier variants but weaker responses against Omicron itself.
View Article and Find Full Text PDF

Aims: To evaluate the impact of a simplified, rapid cardiovascular magnetic resonance (CMR) protocol embedded in care and supported by a partner education programme on the management of cardiomyopathy (CMP) in low- and middle-income countries (LMICs).

Methods And Results: Rapid CMR focused particularly on CMP was implemented in 11 centres, 7 cities, 5 countries, and 3 continents linked to training courses for local professionals. Patients were followed up for 24 months to assess impact.

View Article and Find Full Text PDF
Article Synopsis
  • * Non-invasive ischaemia testing is important for guiding decisions about further procedures, but it can be difficult to conduct and interpret in post-CABG patients due to various complexities in their condition.
  • * Advances in cardiac imaging technology, such as improved image quality and the use of artificial intelligence, present new opportunities to enhance ischaemia testing and understand the underlying health processes affecting CABG patients.
View Article and Find Full Text PDF

Background Long scanning times impede cardiac magnetic resonance (CMR) clinical uptake. A "one-size-fits-all" shortened, focused protocol (eg, only function and late-gadolinium enhancement) reduces scanning time and costs, but provides less information. We developed 2 question-driven CMR and stress-CMR protocols, including tailored advanced tissue characterization, and tested their effectiveness in reducing scanning time while retaining the diagnostic performances of standard protocols.

View Article and Find Full Text PDF

The impact of the initial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infecting strain on downstream immunity to heterologous variants of concern (VOCs) is unknown. Studying a longitudinal healthcare worker cohort, we found that after three antigen exposures (infection plus two vaccine doses), S1 antibody, memory B cells, and heterologous neutralization of B.1.

View Article and Find Full Text PDF

Background: Quantitative myocardial perfusion mapping using cardiovascular magnetic resonance (CMR) is validated for myocardial blood flow (MBF) estimation in native vessel coronary artery disease (CAD). Following coronary artery bypass graft (CABG) surgery, perfusion defects are often detected in territories supplied by the left internal mammary artery (LIMA) graft, but their interpretation and subsequent clinical management is variable.

Methods: We assessed myocardial perfusion using quantitative CMR perfusion mapping in 38 patients with prior CABG surgery, all with angiographically-proven patent LIMA grafts to the left anterior descending coronary artery (LAD) and no prior infarction in the LAD territory.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to explore the prognostic significance of PTT and PBVi using an automated, inline method of estimation using CMR.

Background: Pulmonary transit time (PTT) and pulmonary blood volume index (PBVi) (the product of PTT and cardiac index), are quantitative biomarkers of cardiopulmonary status. The development of cardiovascular magnetic resonance (CMR) quantitative perfusion mapping permits their automated derivation, facilitating clinical adoption.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to detect cardiovascular changes after mild severe acute respiratory syndrome-coronavirus-2 infection.

Background: Concern exists that mild coronavirus disease 2019 may cause myocardial and vascular disease.

Methods: Participants were recruited from COVIDsortium, a 3-hospital prospective study of 731 health care workers who underwent first-wave weekly symptom, polymerase chain reaction, and serology assessment over 4 months, with seroconversion in 21.

View Article and Find Full Text PDF

SARS-CoV-2 vaccine rollout has coincided with the spread of variants of concern. We investigated if single dose vaccination, with or without prior infection, confers cross protective immunity to variants. We analyzed T and B cell responses after first dose vaccination with the Pfizer/BioNTech mRNA vaccine BNT162b2 in healthcare workers (HCW) followed longitudinally, with or without prior Wuhan-Hu-1 SARS-CoV-2 infection.

View Article and Find Full Text PDF

Measurement of myocardial T1 is increasingly incorporated into standard cardiovascular magnetic resonance (CMR) protocols, however accuracy may be reduced in patients with metallic cardiovascular implants. Measurement is feasible in segments free from visual artifact, but there may still be off-resonance induced error. To quantify off-resonance induced T1 error in patients with metallic cardiovascular implants, and validate a method for error correction for a conventional MOLLI pulse sequence.

View Article and Find Full Text PDF

: Most biomedical research has focused on sampling COVID-19 patients presenting to hospital with advanced disease, with less focus on the asymptomatic or paucisymptomatic. We established a bioresource with serial sampling of health care workers (HCWs) designed to obtain samples before and during mainly mild disease, with follow-up sampling to evaluate the quality and duration of immune memory. : We conducted a prospective study on HCWs from three hospital sites in London, initially at a single centre (recruited just prior to first peak community transmission in London), but then extended to multiple sites 3 weeks later (recruitment still ongoing, target n=1,000).

View Article and Find Full Text PDF

T2* mapping techniques has evolved significantly since their introduction in the early 2000s and a significant amount of evidence has been gathered to support their clinical routine use for iron overload assessment. This article focuses on the most important aspects of how to perform T2* imaging, from acquisition, to postprocessing, to analyzing the data with clinical concentration. Newer techniques have made T2* mapping more robust and accurate, allowing a broader use of this technique for noncontrast ischemia imaging based on blood oxygen levels, in addition to evaluation of intramyocardial hemorrhage and microvascular obstruction.

View Article and Find Full Text PDF

Background Advanced cardiac imaging permits optimal targeting of cardiac treatment but needs to be faster, cheaper, and easier for global delivery. We aimed to pilot rapid cardiac magnetic resonance ( CMR ) with contrast in a developing nation, embedding it within clinical care along with training and mentoring. Methods and Results A cross-sectional study of CMR delivery and clinical impact assessment performed 2016-2017 in an upper middle-income country.

View Article and Find Full Text PDF

Aims: To investigate myocardial fibrosis (MF) in a large series of severe aortic stenosis (AS) patients using invasive biopsy and non-invasive imaging.

Methods And Results: One hundred thirty-three patients with severe, symptomatic AS accepted for surgical aortic valve replacement underwent cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) and extracellular volume fraction (ECV) quantification. Intra-operative left ventricular (LV) biopsies were performed by needle or scalpel, yielding tissue with (n = 53) and without endocardium (n = 80), and compared with 10 controls.

View Article and Find Full Text PDF