We have measured the frequency of the extremely narrow 1S-2S two-photon transition in atomic hydrogen using a remote cesium fountain clock with the help of a 920 km stabilized optical fiber. With an improved detection method we obtain f(1S-2S)=2466 061 413 187 018 (11) Hz with a relative uncertainty of 4.5×10(-15), confirming our previous measurement obtained with a local cesium clock [C.
View Article and Find Full Text PDFWe have measured the 1S-2S transition frequency in atomic hydrogen via two-photon spectroscopy on a 5.8 K atomic beam. We obtain f(1S-2S) = 2,466,061,413,187,035 (10) Hz for the hyperfine centroid, in agreement with, but 3.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2010
We have explored the performance of 2 "dark fibers" of a commercial telecommunication fiber link for a remote comparison of optical clocks. These fibers establish a network in Germany that will eventually link optical frequency standards at PTB with those at the Institute of Quantum Optics (IQ) at the Leibniz University of Hanover, and the Max Planck Institutes in Erlangen (MPL) and Garching (MPQ). We demonstrate for the first time that within several minutes a phase coherent comparison of clock lasers at the few 10(-15) level can also be accomplished when the lasers are more than 100 km apart.
View Article and Find Full Text PDF