Introduction: Excessive surgical trauma is believed to be among the most important causes for early implant losses. As thermal injury to the bone is not only dependent on the amount of generated heat but also on the tissue exposure time, and the greatest temperature increase was found within the withdrawing period, the entire osteotomy procedure with the parameters contributing to thermal damage is of particular clinical relevance. The aim of this study was to investigate the thermal performance of metal-based and ceramic implant drills regarding the temperature exposure time during the whole osteotomy process.
View Article and Find Full Text PDFObjectives: The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model.
Material And Methods: A total of 320 automated intermittent osteotomies of 10- and 16-mm drilling depths were performed using zirconium dioxide-based and stainless steel drills. Various drill diameters (2.
Introduction: The aim was to present a novel surgical technique using virtually preplanned 3-dimensional (3D)-printed templates for guided osteotomies. These were to ensure atraumatic uncovering of a severely impacted donor tooth including guided drilling of the recipient alveolus followed by a secure autotransplantation procedure.
Methods: This report presents an autotransplantation procedure of a 14-year-old patient with a severely impacted second premolar and extensive contact to the roots of the adjacent teeth and the inferior alveolar nerve.
The purpose of this article was to present a guided lateral window sinus lift procedure with the aid of a fully digital workflow using surgical templates for window osteotomy preparation and implant placement. A 22-year-old patient with insufficient residual bone height in the posterior maxilla was treated with a maxillary sinus augmentation procedure with a lateral window technique and simultaneous implant installation using 3-dimensionally printed surgical guides. The surgical guides, used for the preparation of both the lateral window and the implant site according to the optimal prosthodontic and anatomic position, were based on a fully digital workflow and virtual pre-planning with modified implant-planning software.
View Article and Find Full Text PDFObjectives:: To evaluate association and causation between maxillary lateral incisors' (MxI2) apical root volume (ARV) and palatally displaced canines (PDC).
Materials And Methods:: In a retrospective cross-sectional study, computed tomography scans of 179 patients with unilateral PDC were analyzed. MxI2 root length and volume on the impaction and eruption side were measured.
Objectives: Impacted and transmigrated mandibular canines differ greatly in incidence, etiopathology, associated anomalies, and treatment prospects, when compared to their maxillary counterparts. The aim of this study was to provide a detailed analysis of 3D radiographic imaging data of impacted mandibular canines.
Materials And Methods: In a retrospective cross-sectional study, CT/CBCT data of 88 patients with a total of 94 impacted mandibular canines were analysed.
J Craniomaxillofac Surg
August 2017
Background: Autotransplantation of teeth (TX) is a predictable treatment option, although this type of therapy is often overlooked compared to other types of restorations.
Purpose: As current literature contains few long-term studies concerning the outcome of autotransplanted immature molars, the aim was to evaluate results after a follow-up period of 5 years.
Material And Methods: This retrospective study enrolled all patients treated with immature autotransplanted molars after a follow-up period of 5 years.
Introduction: Continuous improvements in techniques, instruments, and materials have established modern endodontic microsurgery as a state-of-the-art treatment method. The purpose of this approach was to introduce a new surgical endodontic technique by using a three-dimensional printed template for guided osteotomy and root resection.
Methods: A 38-year-old patient was diagnosed with periapical lesions of teeth #3 and #4 and extruded gutta-percha material.
Introduction: The aim of this study was to introduce an innovative method for autotransplantation of teeth using 3-dimensional (3D) surgical templates for guided osteotomy preparation and donor tooth placement.
Methods: This report describes autotransplantation of immature premolars as treatment of an 11-year-old boy having suffered severe trauma with avulsion of permanent maxillary incisors. This approach uses modified methods from guided implant surgery by superimposition of Digital Imaging and Communications in Medicine files and 3D data sets of the jaws in order to predesign 3D printed templates with the aid of a fully digital workflow.
Purpose: To evaluate the effect of repeat surgery on treatment time in the interdisciplinary management of impacted maxillary canines.
Material And Methods: This retrospective cohort study enrolled patients referred for computed tomographic examination for impacted maxillary canines within a 5-year observational period. The occurrence of repeat surgery was analysed with regard to treatment time, canine location, and surgical exposure technique.
Clin Implant Dent Relat Res
February 2015
Background: Intrabony temperature increase is not only dependent on shearing energy and mechanical friction between bone and surgical drill but is also related to heat capacity and thermal conductivity of the surrounding bone and the applied surgical instrument. Thus time of occurrence of the highest temperature rise can be expected after the shearing process of the osteotomy, potentially affecting the process of osseointegration.
Purpose: The aim of this study was to evaluate temperature changes during the shearing and withdrawing processes during osteotomies.
Objectives: Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling.
Material And Methods: Temperature changes during implant osteotomies (n = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.