Background: The Medtronic Evolut R (EVR) is a novel transcatheter heart valve designed to allow precise implantation at the intended position and to minimize prosthesis dysfunction as well as procedural complications. Our aim was to compare short-term functional and clinical outcomes of the new EVR with the established Medtronic CoreValve (CV) system.
Methods And Results: Of 151 patients undergoing transfemoral transcatheter aortic valve implantation with a self-expanding valve at our institution between January 2013 and January 2016, 86 were treated with EVR and 65 with CV.
Eur Heart J
August 2017
Background: The latest generation transcatheter heart valves including Edwards Sapien 3 (ES3) and Direct Flow Medical (DFM) were designed to allow precise implantation at the intended position and to minimize prosthesis dysfunction as well as procedural complications. Our aim was to compare short-term functional and clinical outcomes of these 2 transcatheter aortic valve systems.
Methods: Of 174 patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) at our institution between August 2013 and June 2015, 113 were treated with ES3 and 61 with DFM.
Background And Purpose: Emboli and proinflammatory mediators are suspected of generating cerebral edema after coronary surgery. In contrast to cardiopulmonary bypass (CPB), off-pump coronary artery bypass surgery (OPCAB) reduces microemboli count and proinflammatory mediator release but carries the risk of hemodynamic instability. A microaxial blood pump can augment cardiac output.
View Article and Find Full Text PDFBackground: During surgical coronary revascularisation hemodynamics and myocardial contractility can be affected. This in vivo study aimed to determine the effects of different operative techniques on hemodynamics and regional myocardial perfusion.
Methods: In 24 pigs IMA to LAD bypass was constructed using ECC (n = 8) and cardioplegic arrest, OPCAB techniques (n = 8), or the Impella elect 100 support device (n = 8).
Background: Median sternotomy is the most frequently used incision for cardiac procedures but carries a substantial risk for deep sternal wound infections and/or sternal dehiscence. In contrast to previous studies that examined risk factors for sternal infections this study evaluates factors that lead to poor outcome after surgical revision of the non healing sternum.
Methods: Between 1985 and 1999, 193 adults (mean age 64 +/- 9 years, m/f = 3/1) necessitated sternal revisions (incidence 1.
Background: Increasing interest has focused on xenotransplantation as a potential solution to the organ shortage. To overcome hyperacute rejection, pigs have been produced that are transgenic for human decay accelerating factor (DAF). For the evaluation of the effects of human DAF, an ex vivo working heart model was used.
View Article and Find Full Text PDFBackground: The physiology of hyperacute rejection of pig lung by human blood and the role of antispecies antibody and complement in this phenomenon have not previously been characterized.
Methods: Human blood was perfused through an ex vivo pig heart-lung preparation. In the treatment groups, blood was either unmodified or modified to deplete alternative pathway complement (heat treatment), anti-pig antibody, or both.
As a potential source of organs for xenotransplantation, pigs that are transgenic for human decay accelerating factor (DAF) have been bred in order to overcome hyperacute rejection. We investigated the protective effect of human DAF in a porcine working heart model perfused by human blood. Hearts of normal landrace pits served as controls.
View Article and Find Full Text PDFProminent components of vascularized xenograft rejection such as platelet activation and microvascular thrombosis may be dependent upon thrombin generation in vivo. To study potential therapeutic benefits of a synthetic low-molecular-weight thrombin inhibitor, SDZ MTH 958, in hyperacute porcine heart rejection by human blood ex vivo, a working model of hyperacute rejection of porcine by fresh, heparinized (6 microM/ml) human blood with or without 1 microM SDZ MTH 958 was used. Thrombin-antithrombin complexes (TAT) and prothrombin fragment F1.
View Article and Find Full Text PDFThe efficacy of acute hemodynamic support with intravenous enoximone (n = 10), (2 x bolus 0.5 mg/kg, infusion 5.0 mcg/kg/min), dopamine (n = 10), (3-4.
View Article and Find Full Text PDF