Publications by authors named "Kasel A"

: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. : We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan.

View Article and Find Full Text PDF

The prognostic significance of renal artery calcification (RAC) is unknown in patients with severe aortic stenosis (AS) eligible for transcatheter aortic valve implantation (TAVI). RAC can be assessed by computed tomography (CT) performed during pre-interventional planning for TAVI. This study aimed at investigating the utility of RAC for predicting survival after TAVI.

View Article and Find Full Text PDF
Article Synopsis
  • * This study analyzed data from over 900 high-risk AF patients to compare outcomes between those receiving LAAO and those getting traditional treatment (mostly oral anticoagulants).
  • * Results showed no significant differences in stroke or cardiovascular death rates, but LAAO patients experienced significantly less clinically relevant bleeding compared to those on conventional treatments.
View Article and Find Full Text PDF
Article Synopsis
  • - The study focuses on vascular complications during transfemoral transcatheter aortic valve implantation (TAVI) and introduces a new risk score called the passage-puncture score to assess the best access site.
  • - This score evaluates two factors: the feasibility of accessing the ilio-femoral arteries (passage score) and the suitability of the puncture site (puncture score) using pre-procedure CT scans.
  • - Results showed that using the passage-puncture score helped identify safer access points and led to a low rate of minor vascular complications (6%) in the patients studied.
View Article and Find Full Text PDF

Aortic Stenosis (AS) is a common condition with an estimated pooled prevalence of all AS in the elderly population at around 12.4%, with that of severe AS estimated to be around 3.4%.

View Article and Find Full Text PDF

Background: Left atrial appendage closure (LAAC) represents an alternative to oral anticoagulation for stroke prevention in patients with non-valvular atrial fibrillation (AF). While transoesophageal echocardiography is the current standard for guiding LAAC procedures, several centers have employed fluoroscopic guidance alone. However, data on long-term outcomes are lacking.

View Article and Find Full Text PDF

Coronary obstruction remains a primary concern for redo transcatheter aortic valve implantation (TAVI) due to supra-annular leaflets. Hereby, we present two valve-in-valve-in-valve cases, initially incorporating a surgical valve implanted to clarify our concept that the surgical valve serves to safeguard against the coronary ostium obstruction.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation.

Aims: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting.

Methods: Valve Academic Research Consortium-2 safety events were assessed up to 1 year.

View Article and Find Full Text PDF

Background: This study aims at investigating left atrial (LA) deformation by left atrial reservoir (LARS) and pump strain (LAPS) and its implications for long-term survival in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI).

Methods: Speckle tracking echocardiography was performed in 198 patients with severe AS undergoing TAVI. Association of strain parameters with cardiovascular mortality was determined.

View Article and Find Full Text PDF

Introduction: This study aims at exploring biventricular remodelling and its implications for outcome in a representative patient cohort with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI).

Methods And Results: Pre-interventional echocardiographic examinations of 100 patients with severe AS undergoing TAVI were assessed by speckle tracking echocardiography of both ventricles. Association with mortality was determined for right ventricular global longitudinal strain (RVGLS), RV free wall strain (RVFWS) and left ventricular global longitudinal strain (LVGLS).

View Article and Find Full Text PDF

A 62-year-old man experienced embolization of a patent foramen ovale (PFO) occlusion device in the pulmonary artery. The device was successfully retrieved using "puncture to loop" technique, without the need of specific materials. This is a challenging retrieval situation, confirming the feasibility and flexibility of the technique.

View Article and Find Full Text PDF

Purpose: To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images.

Materials And Methods: This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4.

View Article and Find Full Text PDF

Background: The next-generation ACURATE neo2 transcatheter aortic valve was designed for simplified implantation and to mitigate the risk of paravalvular leak (PVL) compared to the earlier device.

Aims: To collect clinical outcomes and device performance data, including echocardiography and 4-dimensional computed tomography (4D-CT) data, with the ACURATE neo2 transcatheter heart valve in patients with severe aortic stenosis (AS).

Methods: ACURATE neo2 PMCF is a single-arm, multicentre study of patients with severe AS treated in routine clinical practice.

View Article and Find Full Text PDF

The retrograde valve-crossing of a stenotic aortic valve is a crucial step in the transcatheter aortic valve implantation procedure. In addition to being time-consuming and associated with an increased stroke risk, inappropriate valve-crossing may cause devastating complications. This tutorial review summarizes systematic and detailed techniques to cross the aortic valve.

View Article and Find Full Text PDF

We report the case of a 78-year-old female with Sapien 3 transcatheter heart valve implantation in the transcaval approach. In this setting, we describe the step-by-step management and technique of the transcaval transcatheter aortic valve implantation.

View Article and Find Full Text PDF

The transcatheter aortic valve implantation (TAVI) treatment pathway is complex, leading to procedure-related delays. Dedicated TAVI coordinators can improve pathway efficiency. COORDINATE was a pilot observational prospective registry at three German centers that enrolled consecutive elective patients with severe aortic stenosis undergoing TAVI to investigate the impact a TAVI coordinator program.

View Article and Find Full Text PDF

The transcatheter heart valve (THV) embolization is a rare but challenging complication in transcatheter aortic valve implantation (TAVI). We report the case of an 81-year-old man with Sapien 3 embolization caused by interrupted rapid pacing. In this setting, we describe the embolized THV management and the technique of the second Sapien 3 implantation.

View Article and Find Full Text PDF

Bicuspid aortic valve (BAV) remains challenging in transcatheter aortic valve replacement (TAVR) because of unfavorable anatomy. New-generation balloon-expandable valve (BEV) appears to be a valid alternative to surgery, especially in some Asian countries with a higher prevalence of BAV. This tutorial review summarizes current thinking about how to plan and implant BEV in BAVs using versatile techniques.

View Article and Find Full Text PDF

Background: Bicuspid aortic valve may be associated with increased complications during transcatheter aortic valve implantation (TAVI).

Aims: Compare balloon-expandable transcatheter heart valve (THV) safety and efficacy in severe tricuspid (TAV) and bicuspid (BAV) aortic stenosis.

Methods: Transfemoral TAVI was performed in 743 patients (Jan 2014-June 2019) using the SAPIEN 3 THV.

View Article and Find Full Text PDF

Background Current risk models show limited performances for predicting all-cause mortality after transcatheter aortic valve replacement (TAVR). Purpose To determine the prognostic value of coronary artery calcium (CAC) scoring for predicting 30-day and 1-year mortality in patients undergoing TAVR. Materials and Methods In this single-center institutional review board-approved secondary analysis of prospectively collected data (SwissTAVI Registry), the authors evaluated participants who, before TAVR, underwent CT that included a nonenhanced electrocardiography-gated cardiac scan between May 2008 and September 2019 and who had not undergone previous coronary revascularization.

View Article and Find Full Text PDF

Objectives: To determine with CT the prevalence and extent of mitral annular disjunction (MAD) in patients undergoing transcatheter aortic valve replacement (TAVR) and its association with mitral valve disease and arrhythmia.

Methods: We retrospectively evaluated 408 patients (median age, 82 years; 186 females) with severe aortic stenosis undergoing ECG-gated cardiac CT with end-systolic data acquisition. Baseline and follow-up data were collected in the context of a national registry.

View Article and Find Full Text PDF

We aimed to evaluate the efficacy and safety of a low-dose imaging protocol to reduce intraprocedural radiation during transcatheter aortic valve implantation (TAVI). Observational analysis: 802 transfemoral TAVI patients receiving balloon-expandable devices ≥23 mm at a high-volume centre. After propensity score matching, a standard-dose group (SD, n = 333) treated between January 2014 and February 2016 was compared with a low-dose group (LD, n = 333) treated between August 2017 and March 2019 after departmental uptake of a low-dose imaging protocol (reduced field size, high table height, use of "fluoro save," 3.

View Article and Find Full Text PDF

Purpose: To determine the reliability of subjective and objective quantification of mitral annular calcification (MAC) in elderly patients with severe aortic stenosis, to define quantitative sex- and age-related reference values of MAC, and to correlate quantitative MAC with mitral valve disease.

Methods: In this retrospective, IRB-approved study, we included 559 patients (268 females, median age 81 years, inter-quartile range 77-85 years) with severe aortic stenosis undergoing CT. Four independent readers performed subjective MAC categorization as follows: no, mild, moderate, and severe MAC.

View Article and Find Full Text PDF