Publications by authors named "Karl-Heinz Herrmann"

Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.

Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.

View Article and Find Full Text PDF

Background: Quantifying tumor growth and treatment response noninvasively poses a challenge to all experimental tumor models. The aim of our study was, to assess the value of quantitative and visual examination and radiomic feature analysis of high-resolution MR images of heterotopic glioblastoma xenografts in mice to determine tumor cell proliferation (TCP).

Methods: Human glioblastoma cells were injected subcutaneously into both flanks of immunodeficient mice and followed up on a 3 T MR scanner.

View Article and Find Full Text PDF

Motivation: Systems biology aims to better understand living systems through mathematical modelling of experimental and clinical data. A pervasive challenge in quantitative dynamical modelling is the integration of time series measurements, which often have high variability and low sampling resolution. Approaches are required to utilize such information while consistently handling uncertainties.

View Article and Find Full Text PDF

Background: This study aimed to investigate the effects of tetrahydrolipstatin (orlistat) on heterotopic glioblastoma in mice by applying MRI and correlating the results with histopathology and immunochemistry.

Methods: Human glioblastoma cells were injected subcutaneously into the groins of immunodeficient mice. After tumor growth of >150 mm, the animals were assigned into a treatment group (n = 6), which received daily intraperitoneal injections of orlistat, and a control group (n = 7).

View Article and Find Full Text PDF

The mitogen-activated protein kinase organizer 1 (MORG1) is a scaffold molecule for the ERK signaling pathway, but also binds to prolyl-hydroxylase 3 and modulates HIFα expression. To obtain further insight into the role of MORG1, knockout-mice were generated by homologous recombination. While Morg1+/- mice developed normally without any apparent phenotype, there were no live-born Morg1-/- knockout offspring, indicating embryonic lethality.

View Article and Find Full Text PDF

Background: Preventing sepsis-associated acute kidney injury (S-AKI) can be challenging because it develops rapidly and is often asymptomatic. Probability assessment of disease progression for therapeutic follow-up and outcome are important to intervene and prevent further damage.

Purpose: To establish a noninvasive multiparametric MRI (mpMRI) tool, including T , T , and perfusion mapping, for probability assessment of the outcome of S-AKI.

View Article and Find Full Text PDF

Aging is accompanied by macro-structural alterations in the brain that may relate to age-associated cognitive decline. Animal studies could allow us to study this relationship, but so far it remains unclear whether their structural aging patterns correspond to those in humans. Therefore, by applying magnetic resonance imaging (MRI) and deformation-based morphometry (DBM), we longitudinally screened the brains of male RccHan:WIST rats for structural changes across their average lifespan.

View Article and Find Full Text PDF

Microparticles of iron oxide (MPIOs) are increasingly used for contrast generation in magnetic resonance imaging (MRI). In particular, Dynabeads® MyOne™ Tosylactivated MPIOs have enabled sensitive and targeted molecular imaging, e.g.

View Article and Find Full Text PDF

(1) Background: Pulmonary arterial hypertension (PAH) is a serious condition that is associated with many cardiopulmonary diseases. Invasive right heart catheterization (RHC) is currently the only method for the definitive diagnosis and follow-up of PAH. In this study, we sought a non-invasive hemodynamic biomarker for the diagnosis of PAH.

View Article and Find Full Text PDF

Liver resection causes marked perfusion alterations in the liver remnant both on the organ scale (vascular anatomy) and on the microscale (sinusoidal blood flow on tissue level). These changes in perfusion affect hepatic functions via direct alterations in blood supply and drainage, followed by indirect changes of biomechanical tissue properties and cellular function. Changes in blood flow impose compression, tension and shear forces on the liver tissue.

View Article and Find Full Text PDF

Objectives: To compare the diagnostic value of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the lung versus the gold standard computed tomography (CT) and two T1-weighted MRI sequences in children.

Methods: Twenty-three patients with proven oncologic disease (14 male, 9 female; mean age 9.0 + / - 5.

View Article and Find Full Text PDF

The palatine tonsils form an important part of the human immune system. Together with the other lymphoid tonsils of Waldeyer's tonsillar ring, they act as the first line of defense against ingested or inhaled pathogens. Although histologically stained sections of the palatine tonsil are widely available, they represent the tissue only in two dimensions and do not provide reference to three-dimensional space.

View Article and Find Full Text PDF
Article Synopsis
  • Intense learning can lead to increased grey matter volume in the adult brain, but the mechanisms behind this are not well understood.
  • Researchers used rat models with monocular deprivation to study how learning affects brain structure and to quantify visual acuity with imaging techniques.
  • Findings revealed enhanced vision in the open eye linked to increased grey matter in specific brain regions, along with changes in neuron structure and astrocyte swelling, indicating that learning modifies both synaptic and astrocytic components in the brain.
View Article and Find Full Text PDF

Objectives MR compatible incubators (MRcI) offer the examination of preterm and critically ill infants in controlled environment. The aim of the study was to compare objective and subjective image quality as well as diagnostic value of MRI brain examinations with and without using the MRcI. Thus, predictive value of brain MRI at expected delivery date in general was investigated.

View Article and Find Full Text PDF

Multiple blood cell transfusions may cause iron overload or even liver fibrosis, requiring early diagnosis and intervention. SF is the standard for estimating iron levels in the body, but it also increases with inflammation. We hypothesized that T * magnetic resonance (MR) relaxometry is a more accurate alternative for follow-up in pediatric patients before and after allogenic SCT.

View Article and Find Full Text PDF

Rationale: Delayed ischemic neurological deficit is the most common cause of neurological impairment and unfavorable prognosis in patients with subarachnoid hemorrhage (SAH). Despite the existence of neuroimaging modalities that depict the onset of the accompanying cerebral vasospasm, preventive and therapeutic options are limited and fail to improve outcome owing to an insufficient pathomechanistic understanding of the delayed perfusion deficit. Previous studies have suggested that BOXes (bilirubin oxidation end products), originating from released heme surrounding ruptured blood vessels, are involved in arterial vasoconstriction.

View Article and Find Full Text PDF

Background: Children receiving multiple blood cell transfusions are prone to iron overload and successive tissue damage in liver parenchyma, making noninvasive screening options desirable. Ultrasound (US) elastography using acoustic radiation force impulse (ARFI) imaging enables evaluation of liver parenchyma stiffness, and MRI allows for quantification of liver iron concentration.

Objective: The objective was to correlate US elastography with MRI in children who had undergone bone marrow transplantation and to evaluate the modification of liver tissue with US in combination with clinical parameters at follow-up.

View Article and Find Full Text PDF

The need for extended liver resection is increasing due to the growing incidence of liver tumors in aging societies. Individualized surgical planning is the key for identifying the optimal resection strategy and to minimize the risk of postoperative liver failure and tumor recurrence. Current computational tools provide virtual planning of liver resection by taking into account the spatial relationship between the tumor and the hepatic vascular trees, as well as the size of the future liver remnant.

View Article and Find Full Text PDF

Multimodal imaging has recently attracted much attention due to the advantageous combination of different imaging modalities, like photoluminescence (PL) and magnetic resonance imaging (MRI). In the present study, luminescent and magnetic hydroxyapatites (HAp) were prepared via doping with europium (Eu) and dysprosium (Dy), respectively. Co-doping of Eu and Dy was used to combine the desired physical properties.

View Article and Find Full Text PDF

Acute cellular renal allograft rejection (AR) frequently occurs after kidney transplantations. It is a sterile T-cell mediated inflammation leading to increased local glucose metabolism. Here we demonstrate in an allogeneic model of Brown Norway rat kidneys transplanted into uninephrectomized Lewis rats the successful implementation of the recently developed glucose chemical exchange saturation transfer (glucoCEST) magnetic resonance imaging.

View Article and Find Full Text PDF

This work's aim was to minimize the acquisition time of a radial 3D ultra-short echo-time (UTE) sequence and to provide fully automated, gradient delay compensated, and therefore artifact free, reconstruction. The radial 3D UTE sequence (echo time 60 μs) was implemented as single echo acquisition with center-out readouts and improved time efficient spoiling on a clinical 3T scanner without hardware modifications. To assess the sequence parameter dependent gradient delays each acquisition contained a quick calibration scan and utilized the phase of the readouts to detect the actual k-space center.

View Article and Find Full Text PDF

Unlabelled: The clustered architecture of the brain for different visual stimulus categories is one of the most fascinating topics in the cognitive neurosciences. Interestingly, recent research suggests the existence of additional regions for newly acquired stimuli such as letters (letter form area; LFA; Thesen et al., 2012) and numbers (visual number form area; NFA; Shum et al.

View Article and Find Full Text PDF

Au@Fe3O4 Janus particles (JPs) are heteroparticles with discrete domains defined by different materials. Their tunable composition and morphology confer multimodal and versatile capabilities for use as contrast agents and drug carriers in future medicine. Au@Fe3O4 JPs have colloidal properties and surface characteristics leading to interactions with proteins in biological fluids.

View Article and Find Full Text PDF

The ability to perform small animal functional cardiac imaging on clinical MRI scanners may be of particular value in cases in which the availability of a dedicated high field animal MRI scanner is limited. Here, we propose radial MR cardiac imaging in the rat on a whole-body clinical 3 T scanner in combination with interspersed projection navigators for self-gating without any additional external triggering requirements for electrocardiogram (ECG) and respiration. Single navigator readouts were interspersed using the same TR and a high navigator frequency of 54 Hz into a radial golden-angle acquisition.

View Article and Find Full Text PDF

Purpose: To evaluate low budget 3D printing technology to create MRI compatible components.

Material And Methods: A 3D printer is used to create customized MRI compatible components, a loop-coil platform and a multipart mouse fixation. The mouse fixation is custom fit for a dedicated coil and facilitates head fixation with bite bar, anesthetic gas supply and biomonitoring sensors.

View Article and Find Full Text PDF