Publications by authors named "Karin Obermaier"

Study Objective: To evaluate whether the presence of a visualizable "flow" effect in the fallopian tube ostia in hysteroscopic routine evaluation is predictive of tube patency.

Design: A retrospective cohort study (Canadian Task Force Classification II-2).

Setting: Data from all patients who underwent surgery because of infertility at the study center between 2008 and 2016 were analyzed retrospectively.

View Article and Find Full Text PDF

Background: Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult.

Materials And Methods: Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision.

View Article and Find Full Text PDF

Background: The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that simulates daily life conditions of people with diabetes. Performance was evaluated at low glycemic, euglycemic, and high glycemic ranges as well as during phases with rapid glucose excursions.

Methods: Each of the 30 participants with type 1 diabetes (15 female, age 47 ± 12 years, hemoglobin A1c 7.

View Article and Find Full Text PDF

Background: A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping.

View Article and Find Full Text PDF

Continuous glucose monitoring allows patients with diabetes to check their metabolic status throughout the day, including rarely monitored time periods, such as postprandial and nocturnal periods. The performance of a prototype of the novel SCGM1 System (Roche Diagnostics GmbH, Mannheim, Germany) employing the microdialysis technique was evaluated. Forty-two patients with type 1 diabetes participated in the study [29 males/13 females, age 34 +/- 9 years, duration of diabetes 16 +/- 11 years, glycated hemoglobin 7.

View Article and Find Full Text PDF

The SCGM1 System is designed to allow continuous glucose monitoring in the subcutaneous interstitial fluid for up to 120 h. The system is based on the microdialysis technique and is composed of three components: (1) a disposable Cassette, which contains the microdialysis catheter (with the necessary tubes), an electrochemical flow-through sensor for glucose measurement, and the fluid reservoirs for both the microdialysis perfusate and a reagent solution containing glucose oxidase; (2) the Sensor Unit, which houses the Cassette and is worn by the patient using a belt pack; and (3) the Data Manager, with an integrated blood glucose meter for the calibration of the glucose signal. The Data Manager also has the option of displaying the continuous glucose signal.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionto27950ku2art3s3v51oqkllrnv6lft5): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once