The goal of this project is to improve the quantification of indoor fungal pollutants via the specific application of quantitative PCR (qPCR). Improvement will be made in the controls used in current qPCR applications. This work focuses on the use of two separate controls within a standard qPCR reaction.

View Article and Find Full Text PDF

Endotoxin has established health impacts and may be a potential confounding factor in toxicity studies of engineered nanomaterials (ENM). We aimed to characterize endotoxin contamination for a representative set of carbon-based ENM. The established method for quantifying endotoxin relies on its activity in a complex biochemical assay system.

View Article and Find Full Text PDF

Highly conserved regions are attractive targets for detection and quantitation by PCR, but designing species-specific primer sets can be difficult. Ultimately, almost all primer sets are designed based upon literature searches in public domain databases, such as the National Center for Biotechnology Information (NCBI). Prudence suggests that the researcher needs to evaluate as many sequences as available for designing species-specific PCR primers.

View Article and Find Full Text PDF

Goal, Scope And Background: Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces.

View Article and Find Full Text PDF

Background: A number of studies have observed associations between the amount of endotoxin in urban dust and chronic asthma severity, but a direct relationship between personal exposure to household endotoxin and acute asthma worsening has not yet been defined.

Objective: We sought to investigate the relationship between day-to-day changes in personal endotoxin exposure and asthma severity.

Methods: In the winter and spring of 1999 through 2000, endotoxin exposures were monitored in asthmatic schoolchildren by using portable, as opposed to stationary, monitors designed to measure inhalable and respirable particulate matter less than or equal to 2.

View Article and Find Full Text PDF

Choosing the appropriate floor surface for a school environment is a complex issue. To assist school personnel in determining which flooring is best for their school, we studied the biocontaminant levels associated with carpeted and hard surface flooring. Two schools were selected, one predominantly tiled and one predominantly carpeted, as similar as possible with the exception of their floor coverings.

View Article and Find Full Text PDF

Current recommendations for remediation of fiberglass duct materials contaminated with fungi specify complete removal, which can be extremely expensive, but in-place duct cleaning may not provide adequate protection from regrowth of fungal contamination. Therefore, a common practice in the duct-cleaning industry is the postcleaning use of antifungal surface coatings with the implication that they may contain or limit regrowth. However, even the proper use of these products has generally been discouraged because little research has been conducted on the effectiveness of most products as used in heating, ventilating, and air-conditioning (HVAC) systems.