Background: Local and systemic side effects of glucose remain major limitations of peritoneal dialysis (PD). Glucose transport during PD is thought to occur via inter-endothelial pathways, but recent results show that phloretin, a general blocker of facilitative glucose channels (glucose transporters [GLUTs]), markedly reduced glucose diffusion capacity indicating that some glucose may be transferred via facilitative glucose channels (GLUTs). Whether such transport mainly occurs into (absorption), or across (trans-cellular) peritoneal cells is as yet unresolved.
View Article and Find Full Text PDFBackground: Variation in residual volume between peritoneal dialysis dwells creates uncertainty in ultrafiltration determination, dialysis efficiency, and poses a risk of overfill if the residual volume is large. Measuring the dilution of a marker molecule during fluid fill offers a convenient approach, however, estimation accuracy depends on the choice of dilution marker. We here evaluate the feasibility of creatinine and urea as dilution markers compared to albumin-based residual volumes and three-pore model estimations.
View Article and Find Full Text PDFBackground: Harmful glucose exposure and absorption remain major limitations of peritoneal dialysis (PD). We previously showed that inhibition of sodium glucose cotransporter 2 did not affect glucose transport during PD in rats. However, more recently, we found that phlorizin, a dual blocker of sodium glucose cotransporters 1 and 2, reduces glucose diffusion in PD.
View Article and Find Full Text PDFIntroduction: Glucose absorption during peritoneal dialysis (PD) is commonly assumed to occur via paracellular pathways. We recently showed that SGLT2 inhibition did not reduce glucose absorption in experimental PD, but the potential role of glucose transport into cells is still unclear. Here we sought to elucidate the effects of phlorizin, a non-selective competitive inhibitor of sodium glucose co-transporters 1 and 2 (SGLT1 and SGLT2), in an experimental rat model of PD.
View Article and Find Full Text PDFBackground: The continuous global rise of end-stage kidney disease creates a growing demand of economically beneficial home-based kidney replacement therapies such as peritoneal dialysis (PD). However, undesirable absorption and exposure of peritoneal tissues to glucose remain major limitations of PD.
Methods: We compared a reference (standard) automated PD regimen 6 × 2 L 1.
Introduction: Unwanted glucose absorption during peritoneal dialysis (PD) remains a clinical challenge, especially in diabetic patients. Recent experimental data indicated that inhibitors of the sodium and glucose co-transporter (SGLT)-2 could act to reduce glucose uptake during PD, which raises the question of whether glucose absorption may also occur via intracellular or trans-cellular pathways.
Methods: We performed PD in anesthetized Sprague-Dawley rats using a fill volume of 20 mL with either 1.
Introduction: The osmotic conductance to glucose (OCG) is a crucial determinant of ultrafiltration (UF) in peritoneal dialysis (PD) patients and can be used to monitor membrane integrity in patients on long-term PD. It has been proposed that OCG can be assessed based on drained volumes in 2 consecutive 1-hour glucose dwells, usually 1.5% and 4.
View Article and Find Full Text PDFBackground: It has been estimated that automated peritoneal dialysis (APD) is currently the fastest growing renal replacement therapy in the world. However, in light of the growing number of diabetic patients on peritoneal dialysis (PD), the unwanted glucose absorption during APD remains problematic. Recent results, using an extended 3-pore model of APD, indicated that large reductions in glucose absorption are possible by using optimized bi-modal treatment regimens, having "UF cycles" using a higher glucose concentration, and "Clearance cycles" using a low concentration or, preferentially, no glucose.
View Article and Find Full Text PDF