Publications by authors named "Karim Nasr"

The accurate estimation of gas viscosity remains a pivotal concern for petroleum engineers, exerting substantial influence on the modeling efficacy of natural gas operations. Due to their time-consuming and costly nature, experimental measurements of gas viscosity are challenging. Data-based machine learning (ML) techniques afford a resourceful and less exhausting substitution, aiding research and industry at gas modeling that is incredible to reach in the laboratory.

View Article and Find Full Text PDF

The thinking about metallic replacement has begun in a global context of reducing metallic alloys' use in odontology. Among the materials proposed for their replacement, poly(etheretherketone) may present interesting properties, especially in removable dentures' frames. The purpose of this study is to evaluate fracture resistance of PEEK posts-and-cores compared to non-metallic CAD/CAM materials and fiber glass posts.

View Article and Find Full Text PDF

Wind turbines are devices that convert the kinetic energy present in the wind into clean, sustainable, and effectively renewable energy that could be used to generate electricity. A Savonius wind turbine is a drag-based vertical axis wind turbine (VAWT) that is known to have low noise levels and good starting characteristics even at low wind speeds. Its disadvantage lies in its low efficiency or low coefficient of performance.

View Article and Find Full Text PDF

The objective of this study was to evaluate the variations in the degree of conversion (DC) of a light-curing composite resin when the thickness or the translucency of lithium disilicate-enriched glass-ceramic veneers are modified. IPS e. max CAD blocks of the MT-A2, LT-A2 and MO1 types were cut to obtain four slices with thicknesses ranging from 0.

View Article and Find Full Text PDF

Poly-(etheretherketone) (PEEK) began to be used in the field of odontology more than 10 years ago, especially in relation to the creation of removable partial dentures. Here we report the case of a 62 years old woman diagnosed with histamine intolerance (or histaminosis), who presented a very particular set of oral symptoms. She described a certain tingling, burning, and swelling of the mucous membranes.

View Article and Find Full Text PDF

Objective: This study investigated the chemical and structural changes in the mineral phase and collagen of dentin during application of a mild universal adhesive. Particular attention was paid to the role of isopropanol and changes in water molecules.

Methods: In vitro application of the mild universal adhesive on dentin with two established etching modes (self-etch and etch-and-rinse) was studied using solid state nuclear magnetic resonance spectroscopy.

View Article and Find Full Text PDF

Oral rehabilitation of patients presenting multiple microdontia is a real therapeutic challenge. These alterations in size, often associated with other dental anomalies, have aesthetic and functional repercussions for patients and can lead to significant psycho-social consequences. We report here the case of an 11-year-old patient with bilateral sectorial microdontia and agenesis of teeth numbers 13 and 23.

View Article and Find Full Text PDF

In modern dentistry, Computer-Aided Design and Manufacturing (CAD/CAM) is a promising technology that allows fabrication of prosthetic restorations through milling procedures. Over years, with the continuous improvement of technology, direct CAD/CAM or "chairside" technology is becoming a widespread approach which offers immediate rehabilitation with long-term rates reported by several studies compared to conventional techniques. All steps are generally carried out in the dental office during the same treatment session.

View Article and Find Full Text PDF
Article Synopsis
  • CBCT technology has evolved significantly in oral medicine since the early 2000s, focusing on improved image quality and radiation dose management through advancements like new sensors and algorithms.
  • The technology is now widely used in various fields, primarily in endodontics and oral surgery, while its application is expanding into periodontology and ENT medicine, emphasizing careful use of field of view.
  • Effective use of CBCT requires collaboration among multiple professionals to ensure high standards of care and thorough interpretation of images, including clear communication of findings to patients.
View Article and Find Full Text PDF

Cone Beam Computerized Tomography (CBCT) is an imaging technology increasingly used in dentistry. Depending on the size of the examination area, visualization of anatomical structures outside the indication area may reveal incidental findings (IF). The aims of this systematic review and meta-analysis were to 1) evaluate the frequency, location and different types of incidental findings (IF) revealed during CBCT examinations; 2) identify potential influencing factors such as gender or age; 3) highlight what the family doctor should know about CBCT and the benefits for medical care.

View Article and Find Full Text PDF

Conservation of the three-dimensional aspect of bitemarks is important to optimize their correct analysis. Bitemarks could be recorded with a surface scanner. In clinical dentistry, optical cameras are used as an alternative to conventional dental impressions.

View Article and Find Full Text PDF

After a dental trauma, difficulties of communication and the consequences of the complex clinical situation often make regular chairside oral care long and complicated for special needs patients. The aim of this case report is to show how CAD/CAM technology may help in the prosthetic treatment of a clinical situation by keeping the number and duration of clinical sessions to a minimum while enabling a good aesthetic and functional result to be achieved in the long term.

View Article and Find Full Text PDF

Objectives: In-vitro experiments on ormocers (ORganically MOdified CERamics) have provided controversial results. Consequently, the objectives of this meta-analysis were to (1) compare clinical performances of first generation ormocers versus conventional composite restorations, (2) explore the influence of various clinical factors and the impact of the quality of studies on published results.

Methods: The following databases were explored until 2017/01/08: Ovid MEDLINE In-Process, Pubmed, CENTRAL, HTA, DARE, LILACS and Google Scholar.

View Article and Find Full Text PDF

Background: Dental caries is a common disease and affects many adults worldwide. Inlay or onlay restoration is widely used to treat the resulting tooth substance loss. Two esthetic materials can be used to manufacture an inlay/onlay restoration of the tooth: ceramic or composite.

View Article and Find Full Text PDF

Objectives: The aim of this study was to compare the technique sensitivity of a one-bottle total-etch adhesive and a self-etch primer adhesive to the moisture condition of the dentine substrate.

Methods: The methods used were hydraulic conductance, light microscopy and scanning electron microscopy.

Results: When the moisture conditions of the dentine surface are modified with respect to the standard, the bonded interfaces obtained with the one-bottle total-etch Adper Scotch Bond 1 XT (SB) and the all-in-one self-etch Adper Prompt L-Pop (AP) are morphologically highly perturbed.

View Article and Find Full Text PDF

Objectives: Acrylophosphonic acid (H(2)L) was reacted with biological apatite originating from dental enamel powder in order to identify and study the reaction products formed during the use of self-etch monomers. Nuclear magnetic resonance spectroscopy (NMR) showed the formation of brushite and a calcium salt of acrylophosphonic acid. This Ca salt was further synthesized and characterized by NMR, Fourier transform-infrared (FT-IR) and chromatography coupled with potentiometric analysis.

View Article and Find Full Text PDF

Seven self-etching adhesives were studied on an experimental reconstituted human enamel model. The objective was to evaluate the acid dissociation step of the enamel minerals. The self-etching products were applied to the enamel specimens according to the manufacturers' instructions and then rinsed with distilled water.

View Article and Find Full Text PDF