Publications by authors named "Karen Silbernagel"

Background: The 3MTM Petrifilm™ Rapid Yeast and Mold Count (RYM) Plate is a sample-ready culture medium system which contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration.

Objective: The 3M Petrifilm RYM Plate was validated for the enumeration of yeast and mold in dried cannabis flower through the AOAC Emergency Response Validation process.

Methods: The performance of the 3M Petrifilm RYM Plate was compared to dichloran rose bengal chloramphenicol (DRBC) agar.

View Article and Find Full Text PDF

Background: The 3M™ Petrifilm™ Rapid Aerobic Count (RAC) Plate is a sample-ready culture medium system designed to facilitate colony enumeration in 24 h (48 h for dry powders) for selected food and environmental surfaces.

Objective: The objective of this study is to evaluate the 3M Petrifilm RAC Plate in a matrix extension study for the enumeration of aerobic bacteria on stainless steel, sealed concrete, and rubber surfaces.

Method: The 3M Petrifilm RAC Plate was compared to the U.

View Article and Find Full Text PDF

Background: The 3M™ Petrifilm™ Rapid Yeast and Mold Count (RYM) Plate contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration in 48-60 h.

Objective: The objective of this study is to evaluate the 3M Petrifilm RYM Plate in a matrix extension study for the enumeration of yeast and mold on stainless steel, sealed concrete, and rubber surfaces.

Methods: The 3M Petrifilm RYM Plate was compared to the U.

View Article and Find Full Text PDF

Background: The 3M™ Petrifilm™ Yeast and Mold (YM) Count Plate is a sample-ready culture medium system that contains nutrients supplemented with antibiotics, a cold-water-soluble gelling agent, and an indicator system that facilitates yeast and mold enumeration.

Objective: The 3M Petrifilm YM Plate was validated for enumeration of yeast and mold in dried cannabis flower through the AOAC Emergency Response Validation process.

Methods: The performance of the 3M Petrifilm YM Plate was compared to that of Dichloran Rose Bengal Chloramphenicol (DRBC) agar.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2-Salmonella method is based on real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Salmonella in enriched products. The 3M Molecular Detection Assay 2-Salmonella was approved as AOAC INTERNATIONAL (AOAC) Performance Tested MethodSM (PTM) Certificate No. 091501 and as AOAC Official Method of AnalysisSM2016.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2-STEC Gene Screen (stx and eae) method is based on gene amplification by the use of real time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) and intimin gene (eae) from Shiga toxin-producing Escherichia coli (STEC) in enriched products. The 3M Molecular Detection Assay 2-STEC Gene Screen (stx and eae) was approved as AOAC Performance Tested MethodSM Certificate No. 071902.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2-STEC Gene Screen (stx) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing Escherichia coli (STEC) in enriched products. The 3M Molecular Detection Assay 2-STEC Gene Screen (stx) was approved as AOAC Performance Tested MethodSM Certificate No. 071903.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx and eae) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) and intimin gene (eae) from Shiga toxin-producing enterohemorrhagic Escherichia coli (STEC) in enriched foods.

Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx and eae) method was evaluated as a Level 2 method modification to add new matrixes to the certified claim: 25 g fresh raw ground beef (approximately 75% lean), 375 g fresh raw ground pork (approximately 70% lean), 375 g fresh raw poultry parts, and 25 g sprouts.

Methods: Matrix studies were conducted to assess the method's performance compared to the U.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx) method is based on gene amplification by the use of real-time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing enterohemorrhagic Escherichia coli (STEC) in enriched foods.

Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx) method was evaluated as a Level 2 method modification to add new matrixes to the certified claim: 25 g fresh raw ground beef (approximately 75% lean), 375 g raw beef trim (approximately 75% lean), 375 g fresh raw ground pork (approximately 70% lean), 375 g fresh raw poultry parts, and 25 g sprouts.

Methods: Matrix studies were conducted to assess the method's performance compared to the US Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guidebook, 5C.

View Article and Find Full Text PDF

Background: The 3M™ Molecular Detection Assay 2 - STEC Gene Screen (stx) method is based on gene amplification by the use of real time loop-mediated isothermal amplification when used with the 3M Molecular Detection System for the rapid and specific detection of Shiga toxin gene (stx1 and/or stx2) from Shiga toxin-producing Escherichia coli (STEC) in enriched foods. The stx assay does not differentiate between stx1 and stx2 but detects the presence of stx1 and/or stx2.

Objective: The 3M Molecular Detection Assay 2 - STEC Gene Screen (stx) method was evaluated for AOAC®  Performance Tested MethodsSM certification.

View Article and Find Full Text PDF
Article Synopsis
  • The 3M Molecular Detection Assay 2 - STEC Gene Screen uses gene amplification to quickly identify harmful E. coli strains in food, particularly targeting the Shiga toxin and intimin genes.
  • The method underwent rigorous testing for certification, including checking its accuracy against established USDA and FDA guidelines for different food matrices.
  • Results showed the assay effectively detected all relevant E. coli strains while maintaining consistent performance across different batches, proving it to be a reliable tool for food safety.
View Article and Find Full Text PDF

Background: The 3M™ Petrifilm™ Coliform Count (CC) Plate is a sample-ready-culture medium system which contains modified Violet Red Bile nutrients, a cold-water-soluble gelling agent, and a tetrazolium indicator that facilitates colony enumeration.

Objective: To validate the 3M Petrifilm CC Plate method for bottled water through the AOAC®  Performance Tested Method(s)SM program.

Methods: The performance of the 3M Petrifilm CC Plate was compared to the U.

View Article and Find Full Text PDF

Background: The 3M™ Environmental Scrub Sampler with 10 mL Wide Spectrum Neutralizer is a nonspecific sampling device intended for use for environmental monitoring surface sampling.

Objective: The aim was to evaluate 3M Wide Spectrum Neutralizer using the 3M Environmental Scrub Sampler for AOAC® Performance Tested MethodsSM (PTM) certification.

Methods: Matrix studies, inclusivity/exclusivity, product consistency/stability, neutralization, and robustness testing were conducted for Salmonella and Listeria species.

View Article and Find Full Text PDF

A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay.

View Article and Find Full Text PDF

A multilaboratory study was conducted to compare the automated BAX system and the standard cultural methods for detection of Listeria monocytogenes in foods. Six food types (frankfurters, soft cheese, smoked salmon, raw, ground beef, fresh radishes, and frozen peas) were analyzed by each method. For each food type, 3 inoculation levels were tested: high (average of 2 CFU/g), low (average of 0.

View Article and Find Full Text PDF

A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots.

View Article and Find Full Text PDF

The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--ice cream, raw milk, yogurt, whey powder, and cheese--were analyzed for S.

View Article and Find Full Text PDF

The 3M Petrifilm Staph Express Count plate method was compared with AOAC Official Method 975.55 for the enumeration of Staphylococcus aureus in selected foods. Five foods--frozen lasagna, custard, frozen mixed vegetables, frozen hashbrowns, and frozen batter-coated mushrooms--were analyzed for S.

View Article and Find Full Text PDF

The practice of detecting and enumerating all oxidase-negative, glucose-fermenting-Gram-negative rods (i.e., the family Enterobacteriaceae) is used to indicate unsanitary or inadequate food processing conditions.

View Article and Find Full Text PDF

A collaborative study was conducted to validate new enrichment methods for the TECRA Listeria Visual Immunoassay (TLVIA). These new methods incorporate a newly formulated medium, TECRA Listeria Enrichrment Broth, which does not contain the highly toxic antifungal agent, cycloheximide. The new procedures will provide an alternative to the enrichment procedures described in AOAC Method 995.

View Article and Find Full Text PDF

Results of the 3M Petrifilm Enterobacteriaceae Count (EB) plate method were compared with those of the standard violet red bile glucose agar (VRBG) method for the detection and enumeration of Enterobacteriaceae. Studies involving 107 bacterial strains demonstrated that the Petrifilm EB plate method is as sensitive as and more selective than the VRBG method. Sixty of the 62 pure Enterobacteriaceae cultures were recovered by both methods.

View Article and Find Full Text PDF