Publications by authors named "Kappas C"

Aim: This systematic literature review with meta-analysis aimed to determine the effect of omega-3 long chain polyunsaturated fatty acids on prostaglandin levels and pain severity in women with dysmenorrhoea and identify adverse side effects.

Methods: A literature search was conducted in Embase, Scopus, Web of Science, MEDLINE complete, CINAHL and AMED databases (PROSPERO CRD42022340371). Included studies provided omega-3 long chain polyunsaturated fatty acids compared to a control in women with dysmenorrhoea and reported pain and/or prostaglandin levels.

View Article and Find Full Text PDF

Medical Physics Department (Medical School, University of Thessaly) participated in a Greek National EMF research program (EDBM34) with the scope to measure and evaluate radiofrequency (RF) exposure (27-3000 MHz) in areas of sensitive land use. A thousand (1000) measurements were carried out at two "metropolitan locations" (Athens and Thessaloniki: 624 points) and several rest urban/rural locations (376 points). SRM 3006 spectrum analyzer manufactured by Narda Safety Test Solutions was used.

View Article and Find Full Text PDF

Worldwide, thyroid cancer accounts for some 10% of total cancer incidence, most markedly for females. Thyroid cancer radiotherapy, typically using I (T 8.02 days; β max energy 606 keV, branching ratio 89.

View Article and Find Full Text PDF

The aim of this research paper is to estimate the mean value of extremely low frequency (ELF) exposure in schools in Greece. Detailed ELF measurements were conducted and analyzed by the Weighted Peak Method (WPM), which estimates the overall contribution of electromagnetic waves from 1 Hz to 400 kHz, including their phases. A sample of 243 schools was sampled to calculate.

View Article and Find Full Text PDF

Medical exposure of the general population due to radiological investigations is the foremost source of all artificial ionising radiation. Here, we focus on a particular diagnostic radiological procedure, as only limited data are published with regard to radiation measurements during urethrograpic imaging. Specifically, this work seeks to estimate patient and occupational effective doses during urethrographic procedures at three radiology hospitals.

View Article and Find Full Text PDF

Background: The increasing popularity of mobile phones and the expansion of network infrastructure in Greece have given rise to public concerns about potential adverse health effects on sensitive groups, such as children, from long-term radio-frequency (RF) electromagnetic fields (EMFs) exposure. According to Greek law the RF limit values for sensitive land use (schools, hospitals, etc) have been set to 60% of those recommended by EU standard and 70% for the general population.

Aims: The objective of this study is to estimate mean RF-EMF exposure levels of Greek primary and secondary edu-cation schools located in urban environments.

View Article and Find Full Text PDF

Aims And Objectives: To investigate the value of advanced multiparametric MR imaging biomarker analysis based on radiomic features and machine learning classification, in the non-invasive evaluation of tumor heterogeneity towards the differentiation of Low Grade vs. High Grade Gliomas.

Methods And Materials: Forty histologically confirmed glioma patients (20 LGG and 20 HGG) who underwent a standard 3T-MRI tumor protocol with conventional (T1 pre/post-contrast, T2-FSE, T2-FLAIR) and advanced techniques (Diffusion Tensor and Perfusion Imaging, 1H-MR Spectroscopy), were included.

View Article and Find Full Text PDF

We aim to investigate the counting response variations of positron emission tomography (PET) scanners with different detector configurations in the presence of solitary pulmonary nodule (SPN). Using experimentally validated Monte Carlo simulations, the counting performance of four different scanner models with varying tumor activity, location, and patient obesity is represented using a noise equivalent count rate (NECR). NECR is a well-established quantitative metric which has positive correlation with clinically perceived image quality.

View Article and Find Full Text PDF

Over the years, MR systems have evolved from imaging modalities to advanced computational systems producing a variety of numerical parameters that can be used for the noninvasive preoperative assessment of breast pathology. Furthermore, the combination with state-of-the-art image analysis methods provides a plethora of quantifiable imaging features, termed radiomics that increases diagnostic accuracy towards individualized therapy planning. More importantly, radiomics can now be complemented by the emerging deep learning techniques for further process automation and correlation with other clinical data which facilitate the monitoring of treatment response, as well as the prediction of patient's outcome, by means of unravelling of the complex underlying pathophysiological mechanisms which are reflected in tissue phenotype.

View Article and Find Full Text PDF

Purpose: The management of the occupational exposure to electromagnetic fields (EMF), an Occupational Health and Safety (OHS) issue of great scientific, social and economic significance, was under intense negotiations at European level over the last twenty years; the Directive 2013/35/EU is the new legislative tool. The presented study deals with the practical aspects of the Directive's implementation.

Methods: The appropriate, extensive measurements and the overall EMF exposure assessments (i.

View Article and Find Full Text PDF

The objectives of this study are to assess pediatric radiation exposure in certain barium studies and to quantify the organ and effective doses and radiation risk resultant from patients' irradiation. A total of 69 pediatric barium studies for upper and lower gastrointestinal tract. Patients' radiation dose was quantified in terms of Entrance surface air kerma (ESAKs) using exposure parameters and DosCal software.

View Article and Find Full Text PDF

Occupational Health and Safety (OHS) is associated with crucial social, economic, cultural and technical issues. A highly specialized OHS sector deals with the photobiological hazards from artificial optical radiation (AOR), which is divided into visible light, UV and IR emitted during various activities and which is legally covered by European Directive 2006/25/EC. Among the enormous amount of sources emitting AOR, the most important non-coherent ones to consider for health effects to the whole optical range, are arcs created during metal welding.

View Article and Find Full Text PDF

Background: Lutetium-based scintillators with high-performance electronics introduced time-of-flight (TOF) reconstruction in the clinical setting. Let G' be the total signal to noise ratio gain in a reconstructed image using the TOF kernel compared with conventional reconstruction modes. G' is then the product of G1 gain arising from the reconstruction process itself and (n-1) other gain factors (G2, G3, … Gn) arising from the inherent properties of the detector.

View Article and Find Full Text PDF

Purpose: European legislation concerning the protection of workers from exposure to Electromagnetic Fields (EMF) was recently (26.6.2013) completed by Directive 2013/35/ΕU.

View Article and Find Full Text PDF

The role of conventional Magnetic Resonance Imaging (MRI) in the detection of cerebral tumors has been well established. However its excellent soft tissue visualization and variety of imaging sequences are in many cases non-specific for the assessment of brain tumor grading. Hence, advanced MRI techniques, like Diffusion-Weighted Imaging (DWI), Diffusion Tensor Imaging (DTI) and Dynamic-Susceptibility Contrast Imaging (DSCI), which are based on different contrast principles, have been used in the clinical routine to improve diagnostic accuracy.

View Article and Find Full Text PDF

Introduction: A clinical decision support system (CDSS) for brain tumor classification can be used to assist in the diagnosis and grading of brain tumors. A Fast Spectroscopic Multiple Analysis (FASMA) system that uses combinations of multiparametric MRI data sets was developed as a CDSS for brain tumor classification.

Methods: MRI metabolic ratios and spectra, from long and short TE, respectively, as well as diffusion and perfusion data were acquired from the intratumoral and peritumoral area of 126 patients with untreated intracranial tumors.

View Article and Find Full Text PDF

In recent years, advanced magnetic resonance imaging (MRI) techniques, such as magnetic resonance spectroscopy, diffusion weighted imaging, diffusion tensor imaging and perfusion weighted imaging have been used in order to resolve demanding diagnostic problems such as brain tumor characterization and grading, as these techniques offer a more detailed and non-invasive evaluation of the area under study. In the last decade a great effort has been made to import and utilize intelligent systems in the so-called clinical decision support systems (CDSS) for automatic processing, classification, evaluation and representation of MRI data in order for advanced MRI techniques to become a part of the clinical routine, since the amount of data from the aforementioned techniques has gradually increased. Hence, the purpose of the current review article is two-fold.

View Article and Find Full Text PDF

The advent of PET instrumentation signaled the beginning of a new perspective in nuclear medicine diagnostic imaging. PET systems rely on several corrections that must be applied in order to establish accurate and reliable quantification. The inherent properties of PET detector architecture and the crystals themselves are sources of different types of systematic and random errors with subsequent count rate variability that should be accounted for.

View Article and Find Full Text PDF

The aim of this study is twofold: (a) determination of the spectral differences for flattening-filter-free (FFF) versus standard (STD) linac under various clinical conditions, (b) based on an extensive list of clinically important beam configurations, identification of clinical scenarios that lead to higher macroscopic dose perturbations due to the presence of high-Z material. The focus is on dose enhancement due to contrast agents including high-Z elements such as gold or gadolinium. EGSnrc was used to simulate clinical beams under various irradiation conditions: open/IMRT/spit-IMRT fields, in/out-off-field areas, different depths and field sizes.

View Article and Find Full Text PDF

This study determines the optimal clinical scenarios for gold nanoparticle dose enhancement as a function of irradiation conditions and potential biological targets using megavoltage x-ray beams. Four hundred and eighty clinical beams were studied for different potential cellular or sub-cellular targets. Beam quality was determined based on a 6 MV linac with and without a flattening filter for various delivery conditions.

View Article and Find Full Text PDF

Purpose: To evaluate the diagnostic value of 3T (1)H-MRS in grading cerebral gliomas using short and long echo times.

Methods: 1H-MRS was performed on 71 patients with untreated cerebral gliomas. Metabolite ratios of NAA/Cr, Cho/Cr, Cho/NAA, and mI/Cr were calculated for short and long TE and compared between low and high grade gliomas.

View Article and Find Full Text PDF

Purpose: To determine whether in vivo proton magnetic resonance spectroscopy at 3T can provide accurate breast lesion characterization, and to determine the effect of gadolinium on the resonance of tCho.

Methods: Twenty-four positive-mammogram patients were examined on a 3T MR scanner. 1H-MRS was performed before and after gadolinium administration.

View Article and Find Full Text PDF