Publications by authors named "Kanki Inoue"

Article Synopsis
  • - The POLARx FIT system is a new cryoballoon technology that can adjust in size (28 to 31 mm) and was evaluated against the existing POLARx system for treating atrial fibrillation through pulmonary vein isolation (PVI).
  • - A study involving 70 patients using the POLARx FIT system was compared to 200 patients using the POLARx system, revealing no significant differences in PVI procedure times but a better temperature outcome for the FIT system at the right inferior PV.
  • - Although both systems were effective and safe, the POLARx FIT system showed promise in improving the ablation area while still requiring a smaller balloon size in some cases to ensure complete isolation of pulmonary veins.
View Article and Find Full Text PDF

Background: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are occasionally used in combination with other cardiac implantable electronic devices (CIEDs). However, whether the incidence of inappropriate shock increases in patients with S-ICDs and concomitant CIEDs remains unclear. This study aimed to investigate the association between the concomitant use of CIEDs and the incidence of inappropriate shock in patients with current-generation S-ICDs.

View Article and Find Full Text PDF
Article Synopsis
  • Left ventricular apical aneurysm is linked to serious heart arrhythmias in patients with hypertrophic cardiomyopathy (HCM), yet different guidelines classify its risk level differently, with the 2020 AHA/ACC guidelines recognizing it as a major risk factor.
  • A study with 99 Japanese HCM patients found that those with apical aneurysms, high pressure gradients, or late gadolinium enhancement were more likely to receive appropriate interventions from their implantable cardioverter-defibrillators (ICDs) over an average of 6.2 years.
  • Specifically, the presence of an apical aneurysm significantly increased the annual rate of ICD interventions, indicating the need for careful consideration of these imaging characteristics when deciding
View Article and Find Full Text PDF

Background: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.

Methods and results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate.

View Article and Find Full Text PDF

Unlabelled: An 83-year-old male with complete atrioventricular block underwent dual-chamber pacemaker implantation. Venography showed normal anatomy of the left axillary vein. Following sedation with intravenous propofol, local anesthesia, and skin incision, we punctured the left axillary vein on the first limb.

View Article and Find Full Text PDF

The basis for selection of contemporary ablation technologies for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains unclear. We compared procedural data and efficacy in a propensity score-matched cohort treated with 4 ablation technologies in a center mainly using cryoballoon (CB). A total of 819 consecutive patients with AF underwent PVI, using radiofrequency current (RFC) (65 patients), CB (693 patients), hot balloon (HB) (74 patients), and laser balloon (LB) (52 patients).

View Article and Find Full Text PDF

Background: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear.

Objective: The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode model.

Methods: Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.

View Article and Find Full Text PDF

Background: Anti-mitochondrial antibody (AMA)-associated myopathy is known to be concomitant with primary biliary cirrhosis and to cause both skeletal muscle disorders and arrhythmias, myocardium disorders, and respiratory muscle disorders. We report a case of AMA-associated myopathy in which the bradycardia-related symptoms preceded the skeletal muscle symptoms.

Case Summary: A 59-year-old woman visited the emergency room in our hospital following a syncopal event.

View Article and Find Full Text PDF

The prognostic predictors of death or heart failure hospitalization and the echocardiographic response after initial cardiac resynchronization therapy (CRT) device replacement (CRT-r) remain unclear. We evaluated the predictors and the echocardiographic time course in patients after CRT-r. Consecutive 60 patients underwent CRT-r because of battery depletion.

View Article and Find Full Text PDF

Background: Optimal overlap ratio remains unclear in point-by-point laser balloon (LB) ablation.

Objective: This study sought to determine the optimal overlap strategy with target energies on the acute and chronic outcomes in LB pulmonary vein (PV) isolation (PVI).

Methods: Consecutive 38 patients (148 PVs) with atrial fibrillation underwent the first-generation LB PVI with the following protocols based on the overlap ratios for each PV anterior/posterior wall: 50%/50% (13 patients [49 PVs], group A), 50%/25% (15 patients [60 PVs], group B), and 25%/25% (10 patients [39 PVs], group C).

View Article and Find Full Text PDF

The techniques for successful pacemaker implantation via the PLSVC with the SelectSecure system (Medtronic, Minneapolis, Minnesota, USA) are unknown. Regarding the techniques, we presented a case in which we implanted a pacemaker via the PLSVC in patient with absent RSVC using the SelectSecure system.

View Article and Find Full Text PDF

Background: Functional capacity (FC) correlates with mortality in various cardiovascular diseases. The aim of this study was to examine whether cardiac pacemaker implantations improve the FC and affect the prognosis.

Methods And Results: We prospectively enrolled 621 de novo pacemaker recipients (age 76 ± 9 years, 50.

View Article and Find Full Text PDF

Introduction: Lesion size and continuity in dragging laser balloon (LB) ablation, which may enable fast and durable pulmonary vein isolation for atrial fibrillation, are unknown. We evaluated the differences in size and continuity of linear lesions formed by dragging ablation and conventional point-by-point ablation using an LB in vitro model.

Methods And Results: Chicken muscles were cauterized using the first-generation LB in dragging and point-by-point fashion.

View Article and Find Full Text PDF

Implantable cardioverter-defibrillator (ICD) is effective to prevent sudden death in HCM patients. We reviewed ICD records to analyze the relation between life-threatening arrhythmia and late gadolinium enhancement (LGE) on cardiovascular magnetic resonance (CMR) in Japanese hypertrophic cardiomyopathy (HCM) patients. In 102 consecutive patients (median age 63 years, 63 males) implanted with an ICD after CMR with gadolinium enhancement (median follow-up 2.

View Article and Find Full Text PDF

Background/objectives: Detecting the presence of coronary artery disease (CAD) is critically important in managing patients with heart failure of uncertain cause. The recently introduced 123I-BMIPP/201TlCl dual myocardial single-photon emission computed tomography (dual SPECT) is potentially a non-invasive diagnostic tool in detecting ischemic heart disease. The aim of our study is to evaluate the efficacy of detecting CAD by dual SPECT in patients with heart failure.

View Article and Find Full Text PDF

Background: The use of implantable cardioverter defibrillator (ICD) therapy for congenital heart disease (CHD) has been increasing, but few studies have reported on the efficacy of ICD therapy in Japanese CHD patients.

Method: Twelve CHD patients (median age, 35 years) with first ICD implantation were examined. Median follow-up duration was 2.

View Article and Find Full Text PDF

A 74-year-old woman presented with effort-induced chest pain. Diagnostic coronary angiography revealed three-vessel disease. A successful angioplasty was performed with two sirolimus-eluting stents placed in the left anterior descending artery (LAD) and left circumflex artery (LCX).

View Article and Find Full Text PDF

Background: The maze procedure for the treatment of atrial fibrillation (AF) is a widely used adjunctive therapy. It is necessary to define the precise indications for the procedure based on preoperative factors, but definitive parameters in terms of atrial function have not been well determined.

Methods And Results: In the present study, 55 consecutive patients undergoing the maze procedure for persistent AF in combination with operations for organic heart diseases were evaluated.

View Article and Find Full Text PDF