Background: The pediatric sizes of BlockBuster supraglottic airway (SGA) have been introduced recently. Its efficacy as a conduit for endotracheal intubation in children has not been assessed. Newer devices are often compared with Air-Q SGA to assess their intubating capability.
View Article and Find Full Text PDFBackground: The costoclavicular space serves as an alternative approach to the infraclavicular brachial plexus block, and numerous studies in adults have demonstrated promising outcomes for distal upper limb surgery. Blocking the brachial plexus at this level is potentially advantageous because the cords are relatively superficial, located in close proximity to each other and easily identified using ultrasound.
Aims: This study aimed to assess the success rate and feasibility of costoclavicular block in children undergoing unilateral below elbow upper limb surgery.
Background: Ambu AuraGain has proven to be better compared with other supraglottic airway devices in terms of higher first-attempt insertion success rate, time and ease of insertion, high oropharyngeal leak pressure, and fewer complications in children. The performance of the BlockBuster laryngeal mask has not been evaluated in children.
Aims: The primary objective of this study was to compare the oropharyngeal leak pressure of the BlockBuster laryngeal mask with those of the Ambu AuraGain during controlled ventilation in children.
Purpose: Our study aims to describe a novel low-cost indigenous design of goggles for delivery of oxygen during oxygen supplemented accelerated corneal collagen cross-linking (CXL).
Methods: The goggles were prepared by modifying the safety goggles available in personal protective equipment (PPE) kit. The goggle has two side openings covered with plugs.
Indian J Anaesth
April 2019
Background And Aims: The preterm and ex-preterm babies form a separate group among the paediatric population with unique airway anatomy. The utility of C-MAC Video laryngoscope (VL) for routine intubation of preterm babies has not been evaluated. The purpose of this study is to report the performance of C-MAC VL Miller blade size-0 for endotracheal intubation in preterm babies at our institute.
View Article and Find Full Text PDFBackground: Although sevoflurane is preferred for inhalational induction in children, financial and environmental costs remain major limitations. The aim of this study was to determine if the use of low-fresh gas flow during inhalational induction with sevoflurane could significantly reduce agent consumption, without adversely affecting induction conditions.
Methods: After institutional ethical committee approval, 50 children, aged 1-5 years, undergoing ophthalmic procedures under general anesthesia, were randomized into two groups-standard induction (Group S) and low-flow induction (Group L).
J Anaesthesiol Clin Pharmacol
January 2018
Background And Aims: The ideal time for intravenous (IV) cannulation following inhalational induction in children is debatable. The effect of age on this time has not been studied. We evaluated the optimum time for IV cannulation after sevoflurane induction of anesthesia in different pediatric age groups.
View Article and Find Full Text PDF