A 59-year-old female was admitted for non-ST-segment elevation myocardial infarction and Killip class 3 heart failure with a left ventricular ejection fraction of 30%. Coronary angiogram showed moderate to severe stenosis over the ostial-proximal left anterior descending artery with minor disease over the left circumflex artery and right coronary artery. We describe a complication encountered where a protruding stent was weakened and elongated during our attempts to remove it, risking possible breakage, stent embolization, and long stent protrusion inside the aorta.
View Article and Find Full Text PDFBackground: The use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) decannulation with different percutaneous closure devices has been increasing. At our center, ProGlide devices have been used since November 2018, and Manta devices became an alternative since March 2020. This study aimed to compare the success and complication rates and the clinical outcomes of ProGlide and Manta devices for VA-ECMO decannulation after arteriotomy wound closure.
View Article and Find Full Text PDFIntroduction: The intra-aortic balloon pump (IABP) and Impella are left ventricular unloading devices with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) in place and later serve as bridging therapy when VA-ECMO is terminated. We aimed to determine the potential differences in clinical outcomes and rate of complications between the two combinations of mechanical circulatory support.
Methods: This was a retrospective, single institutional cohort study conducted in the intensive care unit (ICU) of Queen Elizabeth Hospital, Hong Kong.
Percutaneous closure of arteriotomy wound during peripheral venoarterial extracorporeal membrane oxygenation decannulation was shown to be safe and allow earlier mobilization. The new Manta vascular closure device (Essential Medical), designed for the closure of arterotomy wound created by large-bore vascular sheaths up to 25Fr during endovascular catheterization procedures, was reported to be applicable in venoarterial extracorporeal membrane oxygenation decannulation. In this article, we would like to share our experience of using real-time ultrasound guidance to ensure the safe application of Manta during bedside venoarterial extracorporeal membrane oxygenation decannulation.
View Article and Find Full Text PDFSevere calcified coronary lesions are frequently encountered in today's percutaneous coronary intervention practice and remain a challenging entity in complex and high-risk patients. The present case illustrates the contemporary approach to management of this coronary problem from hemodynamic support, optical coherence tomography assessment, and plaque modification technique. ().
View Article and Find Full Text PDF