The demand for synthetic diamonds and research on their use in next-generation semiconductor devices have recently increased. Microwave plasma chemical vapor deposition (MPCVD) is considered one of the most promising techniques for the mass production of large-sized and high-quality single-, micro- and nanocrystalline diamond films. Although the low-pressure resonant cavity MPCVD method can synthesize high-quality diamonds, improvements are needed in terms of the resulting area.
View Article and Find Full Text PDFOptical emission spectroscopy is widely used in semiconductor and display manufacturing for plasma process monitoring. However, because of the contamination of the viewport, quantitative analysis is extremely difficult; therefore, qualitative analysis is used to detect species in the process. To extend plasma monitoring in advanced precise processes, the contamination problem of the viewport must be solved.
View Article and Find Full Text PDFA 9-year-old, intact male Shih Tzu dog presented with systemic weakness and peracute onset of tetraplegia. Tetraplegia with lower motor neuron signs was noted upon neurological examination. Diseases that cause acute flaccid tetraparesis, such as acute fulminating myasthenia gravis, polyradiculoneuritis, tick paralysis, and botulism, were ruled out based on the medical history, normal electrophysiological tests, and non-response to the neostigmine challenging test.
View Article and Find Full Text PDFRelationships of the backscatter coefficient (BC), the apparent integrated backscatter (AIB), and the integrated reflection coefficient (IRC) with the bone mineral density (BMD) and the microarchitectural parameters were investigated in 28 bovine femoral trabecular bone samples. The BC was highly correlated with the BMD and the microarchitectural parameters (R = -0.66 to 0.
View Article and Find Full Text PDFThe ultrasonic backscatter coefficient and the exponent n (frequency dependence of the backscatter coefficient) were measured in 24 bovine femoral trabecular bone samples. The binary mixture model for ultrasonic scattering from trabecular bone was applied to predict the variations of the ultrasound parameters with the bone volume fraction (BV/TV) and the trabecular thickness (Tb.Th) in trabecular bone.
View Article and Find Full Text PDFThe thickness dependences of acoustic bandgaps were theoretically and experimentally investigated in two-dimensional phononic crystals (PCs) immersed in water. The acoustic pressure transmission coefficients were measured as a function of the PC thickness in order to understand the characteristics of the transmission loss through the PCs. The acoustic bandgaps can be classified into two types of generation mechanisms from the perspective of acoustic diffraction modes: Bragg bandgap and non-zeroth order diffraction (NZOD) bandgap.
View Article and Find Full Text PDFJ Acoust Soc Am
November 2018
The phase velocity and the backscatter coefficient were measured in 28 bovine femoral trabecular bone samples filled with marrow and water from 0.2 to 0.6 MHz.
View Article and Find Full Text PDFThis study proposes an acoustic theory that describes the resonance phenomena in a resonator made of acoustic composite right/left-handed (CRLH) metamaterials, and verifies it through numerical simulation. The established theory for a microwave CRLH metamaterial resonator is adapted to explain the resonance phenomena in an acoustic CRLH metamaterial resonator. In particular, attention is focused on the zeroth-order resonance phenomenon which has several interesting properties.
View Article and Find Full Text PDFObjective: This study aimed to investigate the differences in brain morphology according to handedness.
Materials And Methods: Forty-two healthy subjects were enrolled (21 right-handers and 21 nonright-handers). The two groups were classified according to the Edinburgh Handedness Inventory.
The present study aims to investigate the feasibility of using the time-reversed Lamb wave as a new method for noninvasive characterization of long cortical bones. The group velocity of the time-reversed Lamb wave launched by using the modified time reversal method was measured in 15 bovine tibiae, and their correlations with the bone properties of the tibia were examined. The group velocity of the time-reversed Lamb wave showed significant positive correlations with the bone properties (r=0.
View Article and Find Full Text PDFThe novel technique of Plasma-Assisted Vapor Deposition (PAVD) is developed as a new deposition method for thin metal films. The PAVD technique yields a high-quality thin film without any heating of the substrate because evaporated particles acquire energy from plasma that is confined to the inside of the evaporation source. Experiments of silver thin film deposition have been carried out in conditions of pressure lower than 10 Pa.
View Article and Find Full Text PDFThe speed of sound (SOS), the normalized broadband ultrasound attenuation (nBUA), and the nonlinear parameter (B/A) were measured in 18 trabecular-bone-mimicking phantoms consisting of water-saturated aluminum foams. The strong slow wave and the very weak fast wave were consistently observed in the signals transmitted through all of the phantoms. It was found that the SOS increased as the porosity and the trabecular spacing increased.
View Article and Find Full Text PDFConessine, a steroidal alkaloid isolated from Holarrhena floribunda, has anti-malarial activity and interacts with the histamine H3 receptor. However, the cellular effects of conessine are poorly understood. Accordingly, we evaluated the involvement of conessine in the regulation of autophagy.
View Article and Find Full Text PDFBiochem Biophys Res Commun
July 2015
Reserpine is a well-known medicine for the treatment of hypertension and schizophrenia, but its administration can induce Parkinson's disease (PD)-like symptoms in humans and animals. Reserpine inhibits the vesicular transporter of monoamines and depletes the brain of monoamines such as dopamine. However, the cellular function of reserpine is not fully understood.
View Article and Find Full Text PDFThe PKA-CREB signaling pathway is involved in many cellular processes including autophagy. Recent studies demonstrated that PKA-CREB inhibits autophagy in yeast; however, the role of PKA-CREB signaling in mammalian cell autophagy has not been fully characterized. Here, we report that the integral membrane protein ITM2A expression is positively regulated by PKA-CREB signaling and ITM2A expression interferes with autophagic flux by interacting with vacuolar ATPase (v-ATPase).
View Article and Find Full Text PDFThe dependences of ultrasonic properties on the frequency and the trabecular spacing were investigated in 20 trabecular-bone-mimicking phantoms consisting of cellular copper foams. The strong slow waves were consistently observed in the signals transmitted through all of the phantoms. The frequency-dependent phase velocity and attenuation coefficient of the slow wave were measured at frequencies from 0.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2015
The present study aims to investigate the propagation of time-reversed Lamb waves in bovine cortical bone in vitro. The time-reversed Lamb waves were successfully launched at 200 kHz in 18 bovine tibiae through a time reversal process of Lamb waves. The group velocities of the time-reversed Lamb waves in the bovine tibiae were measured using the axial transmission technique.
View Article and Find Full Text PDFThe fluorescent-antibody-to-membrane-antigen (FAMA) test is regarded as the "gold standard" to detect protective antibodies to varicella-zoster virus (VZV) because of its high sensitivity and specificity. Because the classic FAMA test uses an infectious virus for detection of antibodies to VZV, it is labor-intensive, and also requires special equipment for handling the virus. For this reason, we attempted to develop a simple and safe FAMA assay.
View Article and Find Full Text PDFJ Acoust Soc Am
February 2014
The frequency-dependent phase velocity, attenuation coefficient, and backscatter coefficient were measured from 0.8 to 1.2 MHz in 24 water-saturated nickel foams as trabecular-bone-mimicking phantoms.
View Article and Find Full Text PDFIn the present study, correlations of linear and nonlinear ultrasound parameters (speed of sound, normalized broadband ultrasound attenuation, and nonlinear parameter B/A) with bone mineral density and microarchitectural parameters were investigated in 28 bovine femoral trabecular bone samples in vitro. All three ultrasound parameters exhibited relatively high correlation coefficients with the indexes of bone quantity (bone mineral density and bone volume fraction) and lower correlation coefficients with the remaining microarchitectural parameters. These results suggest that B/A, in addition to speed of sound and attenuation, may have potential as an index for the assessment of bone status and osteoporosis.
View Article and Find Full Text PDFThermotherapy uses a heat source that raises temperatures in the target tissue, and the temperature rise depends on the thermal properties of the tissue. Little is known about the temperature-dependent thermal properties of tissue, which prevents us from accurately predicting the temperature distribution of the target tissue undergoing thermotherapy. The present study reports the key thermal parameters (specific heat capacity, thermal conductivity and heat diffusivity) measured in ex vivo porcine liver while being heated from 20 ° C to 90 ° C and then naturally cooled down to 20 ° C.
View Article and Find Full Text PDFAn optically transparent tissue-mimicking (TM) phantom whose acoustic properties are close to those of tissue was constructed for visualizing therapeutic effects by high intensity focused ultrasound (HIFU). The TM phantom was designed to improve a widely used standard bovine serum albumin (BSA) polyacrylamide hydrogel (PAG), which attenuated ultrasound far less than tissue and, unlike tissue, did not scatter ultrasound. A modified recipe has been proposed in the study by adding scattering glass beads with diameters of 40-80 μm (0.
View Article and Find Full Text PDFJ Acoust Soc Am
December 2012
Speed of sound (SOS) was measured in 14 bovine femoral trabecular bone samples with and without the cortical endplates with various thicknesses of 1.00, 1.31, 1.
View Article and Find Full Text PDFJ Acoust Soc Am
October 2012
Phase velocity and normalized broadband ultrasound attenuation (nBUA) were measured in 22 marrow-filled and water-filled bovine femoral trabecular bone samples. Replacement of marrow by water led to a significant increase in the mean phase velocity of 47 ± 12 m/s (+3.1%), but a decrease in the mean nBUA of 10.
View Article and Find Full Text PDFCorrelations between ultrasonic guided wave velocities and bone properties were investigated in bovine tibia in vitro. The velocities of the first arriving signal and the slow guided wave, termed V(FAS) and V(SGW), along the long axis of the tibia were measured at 200 kHz in 20 bovine tibiae using the axial transmission technique. V(FAS) yielded significant negative correlation coefficients of -0.
View Article and Find Full Text PDF