Purpose: Artery contrasted computed tomography (CT) enables accurate observations of the arteries and surrounding structures, thus being widely used for the diagnosis of diseases such as aneurysm. To avoid the complications caused by contrast agent, this paper proposes an aorta-aware deep learning method to synthesize artery contrasted CT volume form non-contrast CT volume.
Methods: By introducing auxiliary multi-resolution segmentation tasks in the generator, we force the proposed network to focus on the regions of aorta and the other vascular structures.
The volumes of intracranial tissues of 40 healthy volunteers acquired from 0.3- and 3-T scanners were compared using intraclass correlation coefficients, correlation analyses, and Bland-Altman analyses. We found high intraclass correlation coefficients, high Pearson's correlation coefficients, and low percentage biases in all tissues and most of the brain regions, although small differences were observed in some areas.
View Article and Find Full Text PDFObjective: With the initiative of the ACR International Economics Committee, a multinational survey was conducted to evaluate radiology residency programs around the world.
Methods: A 31-question survey was developed. It included: economic issues, program size and length, resident's activities during daytime and call, academic aspects including syllabus and examinations.
Background: 3D printed patient-specific coronary models have the ability to enable repeatable benchtop experiments under controlled blood flow conditions. This approach can be applied to CT-derived patient geometries to emulate coronary flow and related parameters such as Fractional Flow Reserve (FFR).
Methods: This study uses 3D printing to compare such benchtop FFR results with a non-invasive CT-FFR research software algorithm and catheter based invasive FFR (I-FFR) measurements.
Background: Three-dimensional printing (3DP) offers a unique opportunity to build flexible vascular patient-specific coronary models for device testing, treatment planning, and physiological simulations. By optimizing the 3DP design to replicate the geometrical and mechanical properties of healthy and diseased arteries, we may improve the relevance of using such models to simulate the hemodynamics of coronary disease. We developed a method to build 3DP patient specific coronary phantoms, which maintain a significant part of the coronary tree, while preserving geometrical accuracy of the atherosclerotic plaques and allows for an adjustable hydraulic resistance.
View Article and Find Full Text PDFPurpose: The aim of this study was to determine the status of radiology quality improvement programs in a variety of selected nations worldwide.
Methods: A survey was developed by select members of the International Economics Committee of the American College of Radiology on quality programs and was distributed to committee members. Members responded on behalf of their country.
Rationale And Objectives: Fractional flow reserve (FFR) is an established technique for detecting lesion-specific ischemia but is invasive. Our objective was to investigate the effects of combined assessment of coronary CT angiography (CCTA) imaging features and CT-FFR on detecting lesion-specific ischemia by comparing with invasive FFR.
Materials And Methods: Forty-seven patients who had 60 coronary vessels with 30%-90% stenosis were included.
Objectives: Quantitative synthetic magnetic resonance imaging (MRI) enables synthesis of various contrast-weighted images as well as simultaneous quantification of T1 and T2 relaxation times and proton density. However, to date, it has been challenging to generate magnetic resonance angiography (MRA) images with synthetic MRI. The purpose of this study was to develop a deep learning algorithm to generate MRA images based on 3D synthetic MRI raw data.
View Article and Find Full Text PDFBackground: Previous methods for the quantification of brain tissue properties by magnetic resonance imaging were mainly based on two-dimensional acquisitions and were thus limited to a relatively low resolution in the slice direction compared to three-dimensional (3D) acquisitions. The 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) sequence may allow for simultaneous acquisition of relaxometry parameters in high spatial resolution.
Purpose: To evaluate bias, linearity, and day-to-day repeatability of relaxometry parameters, as well as tissue fraction maps, acquired with 3D-QALAS.
Purpose: Gadolinium-based contrast agents (GBCA) provide valuable information for assessing and differentiating lesions in the body. However, contrast enhancement evaluation on conventional MRI is qualitative because the signal intensity uses an arbitrary scale. An approach that allows more quantitative assessment of tissue enhancement that can be integrated into clinical use is desirable.
View Article and Find Full Text PDFThe purpose of this study was to show the efficacy of dynamic field correction (DFC), a technique provided by the scanner software, in comparison to the FMRIB Software Library (FSL) post-processing "eddy" tool. DFC requires minimal additional scan time for the correction of eddy-current and motion-induced geometrical image distortions in diffusion-weighted echo-planar images. The fractional anisotropy derived from images corrected with DFC were comparable to images corrected with the "eddy" tool and significantly higher than images without correction, which demonstrates the utility of DFC.
View Article and Find Full Text PDFInvest Radiol
January 2019
Objectives: The aim of this study was to evaluate the linearity, bias, intrascanner repeatability, and interscanner reproducibility of quantitative values derived from a multidynamic multiecho (MDME) sequence for rapid simultaneous relaxometry.
Materials And Methods: The NIST/ISMRM (National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine) phantom, containing spheres with standardized T1 and T2 relaxation times and proton density (PD), and 10 healthy volunteers, were scanned 10 times on different days and 2 times during the same session, using the MDME sequence, on three 3 T scanners from different vendors. For healthy volunteers, brain volumetry and myelin estimation were performed based on the measured T1, T2, and PD.
Magnetization transfer (MT) imaging has been widely used for estimating myelin content in the brain. Recently, two other approaches, namely simultaneous tissue relaxometry of R and R relaxation rates and proton density (SyMRI) and the ratio of T-weighted to T-weighted images (Tw/Tw ratio), were also proposed as methods for measuring myelin. SyMRI and MT imaging have been reported to correlate well with actual myelin by histology.
View Article and Find Full Text PDFMapping of MR fiber g-ratio, which is the ratio of the diameter of the axon to the diameter of the neuronal fiber, is introduced in this article. We investigated the MR fiber g-ratio, the axon volume fraction (AVF) and the myelin volume fraction (MVF) to evaluate microstructural changes in the spinal cord in patients with cervical spondylotic myelopathy (CSM) in vivo, using atlas-based analysis. We used diffusion MRI data acquired with a new simultaneous multi-slice accelerated readout-segmented echo planar imaging sequence for diffusion analysis for AVF calculation and magnetization transfer saturation imaging for MVF calculation.
View Article and Find Full Text PDFConventional magnetic resonance images are usually evaluated using the image signal contrast between tissues and not based on their absolute signal intensities. Quantification of tissue parameters, such as relaxation rates and proton density, would provide an absolute scale; however, these methods have mainly been performed in a research setting. The development of rapid quantification, with scan times in the order of 6 minutes for full head coverage, has provided the prerequisites for clinical use.
View Article and Find Full Text PDFBackground: Synthetic magnetic resonance imaging (MRI), a technique that enables creation of various contrast-weighted images from a single MRI quantification scan, is a useful clinical tool. However, there are currently no reports examining the use of contrast-enhanced synthetic MRI for detecting brain metastases.
Purpose: To assess whether contrast-enhanced synthetic MRI is suitable for detecting brain metastases.
Background: The characteristics and aetiology of pneumonia in the non-elderly population is distinct from that in the elderly population. While a few studies have reported an inverse association between hospital case volume and clinical outcome in elderly pneumonia patients, the evidence is lacking in a younger population. In addition, the relationship between volume and outcome may be different in severe pneumonia cases than in mild cases.
View Article and Find Full Text PDFWe report a case of a 71-year-old man with a mycotic aneurysm of the aortic arch who presented with progressive hoarseness. Three weeks prior to this event the patient was admitted to an outside hospital in septic condition and was diagnosed with a mycotic abdominal aortic aneurysm. Resection of the infected abdominal aortic aneurysm with right axillofemoral and femoral-femoral bypass grafts was performed and the patient was discharged home on intravenous antibiotics.
View Article and Find Full Text PDFObjective: To investigate a new modified computed tomographic (CT) ellipsoid method of split renal function and to compare results from this method with other CT-derived metrics.
Methods: Thirty-eight potential renal donors with both CT and nuclear renography were retrospectively evaluated for estimated split function using 6 CT methods to determine accuracy. For the CT methods, correlation, reproducibility, ease in image post-processing, and the ability of CT-derived methods to determine the dominant kidney before renal transplantation were evaluated using a nuclear renography reference standard.