Integrated absolute full energy peak efficiency (IAFEPE) is a measure of photon registration efficiency using the γ-ray spectrometry method. We have derived appropriate formulas and theoretical explanations of IAFEPE for the first time. IAFEPE is a definite integral (Riemann integral) of the photon registration efficiency function within the detection energy range.
View Article and Find Full Text PDFThe presented research was focused on the analysis of the impact of biochar application into the soil on the radon exhalation process as a new issue of radiation protection in agriculture. Field measurements of the radon exhalation rate utilizing two methods-active and passive as well as laboratory measurements of the radon emanation coefficient were performed. In laboratory a soil samples with sunflower husk biochar were analysed using the accumulation chamber technique.
View Article and Find Full Text PDFBiochar application has been reported to improve the physical, chemical, and hydrological properties of soil. However, the information about the size fraction composition of the applied biochar as a factor that may have an impact on the properties of soil-biochar mixtures is often underappreciated. Our research shows how sunflower husk biochar (pyrolyzed at 650 °C) can modify the water retention characteristics of arable sandy soil depending on the biochar dose (up to 9.
View Article and Find Full Text PDFBiochar (charcoal made from biomass in the pyrolysis process) has found broad application in agriculture. It helps to improve both the physical and chemical properties of soil through decontamination of heavy metals and pesticides. This work examines the potential for biochar application to improve the radiological condition of soil.
View Article and Find Full Text PDFWater resources on Earth become one of the main concerns for society. Therefore, remote sensing methods are still under development in order to improve the picture of the global water cycle. In this context, the microwave bands are the most suitable to study land-water resources.
View Article and Find Full Text PDFBackground: The calibration of the dosimetric instruments is a basis of safety of the people working with the ionization radiation. The necessity of calibration is especially important in the institutions where the open radioactive sources are used. The paper presents the abilities of CLOR's radiological protection instruments calibration facility and the important conclusions from calibrations results for group of instruments used in Nuclear Medicine Department in Poland.
View Article and Find Full Text PDFJ Radioanal Nucl Chem
January 2016
Plasma experiments conducted on the PF-1000 device generate the release of neutrons and ionizing radiation that are the source of immediate exposure to personnel. Neutron activation of materials in the research device and the surroundings is a source of ongoing radiation exposure to the same personnel. Having reported on personnel exposure from ionizing radiation and neutron activation, we now aim to characterize exposure from direct neutron emission generated by the device, and describe the process of ensuring measurement accuracy.
View Article and Find Full Text PDFPresented paper describes the results of the individual doses measurements for ionizing radiation, carried out by the Laboratory of Individual and Environmental Doses Monitoring (PDIS) of the Central Laboratory for Radiological Protection in Warsaw (CLOR) for the medical staff employees in several nuclear medicine (NM) departments across Poland. In total there are48 NM departments in operation in Poland [1] (consultation in Nuclear Atomic Agency). Presented results were collected over the period from January 2011 to December 2011 at eight NM departments located in Krakow, Warszawa (two departments), Rzeszow (two departments), Opole, Przemysl and Gorzow Wielkopolski.
View Article and Find Full Text PDFResults of individual monitoring of occupied workers based on the doses estimations carried out by Central Laboratory for Radiological Protection (CLOR) in Warsaw has been presented. In 2011, about 5000 persons from 330 institutions were monitored. Monitoring service in CLOR is based on two doses assessment methods, Kodak films and MCP-N thermo luminescent detectors.
View Article and Find Full Text PDF