Purpose: This study aimed to investigate the long-term outcomes of patients with a femoral neck fracture (FNF), treated with the Dynamic Locking Blade Plate (DLBP).
Methods: Retrospective analysis of prospectively collected data of a multicentre cohort of patients with FNFs was conducted, regarding the long-term incidence of revision surgery after DLBP. Implant failure was evaluated using Kaplan-Meier and Cox regression analysis.
Introduction: This systematic review aims to provide an overview of predictors for failure of treatment of displaced femoral neck fracture (dFNF) with internal fixation and quantify their risk of fixation failure in a meta-analysis.
Patients And Methods: PubMed, Embase, Web of Science, Cochrane Library, and EMCare were searched for original studies published from January 2000, including adult patients with an internally fixated dFNF, that reported data on predictors for fixation failure defined as revision surgery due to non-union, avascular femoral head necrosis or cut-out of implant. RevMan version 5 software was used to pool univariable Odds Ratio's (OR) for predictors of fixation failure by means of a random effects model.
Purpose: In this study, we aimed to determine the correlation between the preoperative posterior tilt of the femoral head and treatment failure in patients with a Garden type I and II femoral neck fracture (FNF) treated with the dynamic locking blade plate (DLBP).
Methods: Preoperative posterior tilt was measured in a prospective documented cohort of 193 patients with a Garden type I and II FNF treated with the DLBP. The correlation between preoperative posterior tilt and failure, defined as revision surgery because of avascular necrosis, non-union, or cut-out, was analyzed.
Background: The Dynamic Locking Blade Plate (DLBP) was recently introduced for fixation of displaced femoral neck fractures (FNF) and has been well received. Although the results of this implant in young patients are promising, the DLBP has not yet been compared to a standard device such as the Dynamic Hip Screw (DHS). The aim of this study is to compare the clinical outcome and costs of displaced FNF treated with internal fixation by means of either the DLBP or the DHS in patients up to 65 years of age.
View Article and Find Full Text PDFIntroduction: Posterior tilt of the femoral head in femoral neck fractures (FNF) may influence stability of the fracture and may therefore affect the treatment outcome. Posterior tilt can be measured with different methods. The Lateral Garden Angle (LGA) has been used for this purpose for decades and more recently the Posterior Tilt Measurement (PTM) was introduced.
View Article and Find Full Text PDFAims: The objective of this study was to investigate bone healing after internal fixation of displaced femoral neck fractures (FNFs) with the Dynamic Locking Blade Plate (DLBP) in a young patient population treated by various orthopaedic (trauma) surgeons.
Patients And Methods: We present a multicentre prospective case series with a follow-up of one year. All patients aged ≤ 60 years with a displaced FNF treated with the DLBP between 1st August 2010 and December 2014 were included.
Eur J Trauma Emerg Surg
August 2017
Background: This study evaluated the clinical results of a new implant in the internal fixation of undisplaced femoral neck fractures.
Method: Irrespective of their age, 149 patients with undisplaced (Garden I and II) femoral neck fractures were included in a prospective multicentre clinical cohort study and were treated by internal fixation by means of the Dynamic Locking Blade Plate (DLBP). The mean age was 69 years and the follow-up at least one year.
Tijdschr Soc Geneeskd
September 1965