Purpose: Using X-ray micro-computed tomography (micro-CT), the aim of this study was to measure the porosity of two tricalcium silicate sealers (EndoSequence BC and NeoSealer Flo) applied using three obturation techniques (single-cone, warm-vertical, and cold-lateral) to six single-rooted human teeth.
Methods: Six extracted, single-rooted human teeth were shaped with ProTaper Next rotary files and obturated with EndoSequence BC or NeoSealer Flo sealers and gutta-percha (GP) using one of the three techniques above. Micro-CT was used to map the full length of the canals.
Purpose: The aim of this study was to categorize the effects of heat on coronal obturation with gutta-percha and sealer using X-ray micro-computed tomography (micro-CT).
Methods: Ten single-rooted, extracted human teeth were shaped using ProTaper NEXT files to size X5 (#50/Taper 6%) with 2.5% NaOCl irrigation.
Purpose: The aim of this study was to use dye penetration to measure apical and coronal leakage simultaneously in single-canal teeth that had been treated endodontically using a single-cone obturation technique.
Methods: One hundred single-canal, extracted human teeth were cleaned and shaped with ProTaper NEXT rotary files to size-X5 (50/.06), then randomly assigned to five sealer groups for single-cone gutta-percha obturation.