Non-alcoholic fatty liver disease (NAFLD) is a significant cause of diffuse liver disease, morbidity and mortality worldwide. Early and accurate diagnosis of NALFD is critical to identify patients at risk of disease progression. Liver biopsy is the current gold standard for diagnosis and prognosis.
View Article and Find Full Text PDFThis study validates a non-invasive, quantitative technique to diagnose steatosis within tissue. The proposed method is based on two fundamental concepts: (i) the speed of sound in a fatty liver is lower than that in a healthy liver and (ii) the quality of an ultrasound image is maximized when the beamformer's speed of sound matches the speed in the medium under examination. The method uses image brightness and sharpness as quantitative image-quality metrics to predict the true sound speed and capture the effects of fat infiltration, while accounting for the transmission through subcutaneous fat.
View Article and Find Full Text PDFNon-alcoholic fatty liver disease is a condition that is characterized by the presence of >5% fat in the liver and affects more than one billion people worldwide. If adequate and early precautions are not taken, non-alcoholic fatty liver disease can progress to cirrhosis and death. The current reference standard for detecting hepatic steatosis is a liver biopsy.
View Article and Find Full Text PDFDescribed here is a method to determine the longitudinal speed of sound in speckle-dominated ultrasound images. The method is based on the concept that the quality of an ultrasound image is maximized when the beamformer's speed of sound matches the speed in the medium. The method captures the quality of the ultrasound image using two quantitative image-quality metrics: image brightness and sharpness around the intended focal zone.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
May 2018
We propose a column-row-parallel imaging front-end architecture for integrated and low-power 3-D medical ultrasound imaging. The column-row-parallel architecture offers linear-scaling interconnection, acquisition, and programming time with row-by-row or column-by-column operations, while supporting volumetric imaging functionality and fault-tolerance against possible transducer element defects with per-element controls. The combination of column-parallel selection logic, row-parallel selection logic, and per-element selection logic reaches a balance between flexible imaging aperture definition and manageable imaging data/control interface to a 2-D array.
View Article and Find Full Text PDFBackground: Low levels of HDL-C are an independent cardiovascular risk factor associated with increased premature cardiovascular death. However, HDL-C therapies historically have been limited by issues relating to immunogenicity, hepatotoxicity and scalability, and have been ineffective in clinical trials.
Objective: We examined the feasibility of using injectable acoustic microspheres to locally deliver human ApoA-I DNA plasmids in a pre-clinical model and quantify increased production of HDL-C in vivo.
IEEE Trans Ultrason Ferroelectr Freq Control
March 2015
Ability to visualize breast lesion vascularity and quantify the vascular heterogeneity using contrast-enhanced 3-D harmonic (HI) and subharmonic (SHI) ultrasound imaging was investigated in a clinical population. Patients (n = 134) identified with breast lesions on mammography were scanned using power Doppler imaging, contrast-enhanced 3-D HI, and 3-D SHI on a modified Logiq 9 scanner (GE Healthcare). A region of interest corresponding to ultrasound contrast agent flow was identified in 4D View (GE Medical Systems) and mapped to raw slice data to generate a map of time-intensity curves for the lesion volume.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2013
A promising transducer architecture for largearea arrays employs 2-D capacitive micromachined ultrasound transducer (CMUT) devices with backside trench-frame pillar interconnects. Reconfigurable array (RA) application-specified integrated circuits (ASICs) can provide efficient interfacing between these high-element-count transducer arrays and standard ultrasound systems. Standard electronic assembly techniques such as flip-chip and ball grid array (BGA) attachment, along with organic laminate substrate carriers, can be leveraged to create large-area arrays composed of tiled modules of CMUT chips and interface ASICs.
View Article and Find Full Text PDFMosaic annular arrays (MAA) based on reconfigurable array (RA) transducer electronics assemblies are presented as a potential solution for future highly integrated ultrasonic transducer subsystems. Advantages of MAAs include excellent beam quality and depth of field resulting from superior elevational focus compared with 1-D electronically scanned arrays, as well as potentially reduced cost, size, and power consumption resulting from the use of a limited number of beamforming channels for processing a large number of subelements. Specific design tradeoffs for these highly integrated arrays are discussed in terms of array specifications for center frequency, element pitch, and electronic switch-on resistance.
View Article and Find Full Text PDFObjectives: The ability to estimate tissue perfusion (in milliliter per minute per gram) in vivo using contrast-enhanced 3-dimensional (3D) harmonic and subharmonic ultrasound imaging was investigated.
Materials And Methods: A LOGIQ™ 9 scanner (GE Healthcare, Milwaukee, WI) equipped with a 4D10L probe was modified to perform 3D harmonic imaging (HI; f(transmit), 5 MHz and f(receive), 10 MHz) and subharmonic imaging (SHI; f(transmit), 5.8 MHz and f(receive), 2.
Purpose: To compare subharmonic aided pressure estimation (SHAPE) with pressure catheter-based measurements in human patients with chronic liver disease undergoing transjugular liver biopsy.
Materials And Methods: This HIPAA-compliant study had U.S.
IEEE Trans Ultrason Ferroelectr Freq Control
March 2013
Vibro-acoustography (VA) is an ultrasound-based imaging modality that uses radiation force produced by two cofocused ultrasound beams separated by a small frequency difference, Δf, to vibrate tissue at Δf. An acoustic field is created by the object vibration and measured with a nearby hydrophone. This method has recently been implemented on a clinical ultrasound system using 1-D linear-array transducers.
View Article and Find Full Text PDFThe efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (f(transmit): 2.5 MHz, f(receive): 1.
View Article and Find Full Text PDFRationale And Objectives: Although contrast-enhanced ultrasound imaging techniques such as harmonic imaging (HI) have evolved to reduce tissue signals using the nonlinear properties of the contrast agent, levels of background suppression have been mixed. Subharmonic imaging (SHI) offers near complete tissue suppression by centering the receive bandwidth at half the transmitting frequency. The aims of this study were to demonstrate the feasibility of three-dimensional (3D) SHI and to compare it to 3D HI.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2011
A method is introduced to monitor cardiac ablative therapy by examining slope changes in the thermal strain curve caused by speed of sound variations with temperature. The sound speed of water-bearing tissue such as cardiac muscle increases with temperature. However, at temperatures above about 50°C, there is no further increase in the sound speed and the temperature coefficient may become slightly negative.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
June 2011
Vibro-acoustography is an ultrasound-based imaging modality that uses two ultrasound beams of slightly different frequencies to produce images based on the acoustic response caused by harmonic ultrasound radiation force excitation at the difference frequency between the two ultrasound frequencies. Vibro-acoustography has demonstrated feasibility and usefulness in imaging of breast and prostate tissue. However, previous studies have been performed either in controlled water tank settings or a prototype breast scanner equipped with a water tank.
View Article and Find Full Text PDFThe thermal index (TI) has been used as a relative indicator of thermal risk during diagnostic ultrasound examinations for many years. It is useful in providing feedback to the clinician or sonographer, allowing assessment of relative, potential risks to the patient of an adverse effect due to a thermal mechanism. Recently, several shortcomings of the TI formulations in quantifying the risk to the patient have been identified by members of the basic scientific community, and possible improvements to address these shortcomings have been proposed.
View Article and Find Full Text PDFProliferation of the adventitial vasa vasorum (VV) is inherently linked with early atherosclerotic plaque development and vulnerability. Recently, direct visualization of arterial VV and intraplaque neovascularization has emerged as a new surrogate marker for the early detection of atherosclerotic disease. This clinical review focuses on contrast-enhanced ultrasound (CEUS) as a noninvasive application for identifying and quantifying carotid and coronary artery VV and intraplaque neovascularization.
View Article and Find Full Text PDFObjective: The goal of this work was to evaluate a possible improvement in ultrasound coverage for a dual-modality breast imaging system in the mammographic geometry.
Methods: A pilot study was performed to evaluate use of a rubber dam to retain ultrasound gel and improve imaging coverage at the breast periphery on a combined imaging system consisting of an ultrasound scanner and a digital x-ray tomosynthesis unit. Several dams were constructed to encompass the shapes of various sizes of compressed breasts.
IEEE Trans Ultrason Ferroelectr Freq Control
June 2010
Reconfigurable arrays offer an advantage over traditional ultrasound arrays because of their flexibility in channel selection. To improve ultrasound beamforming and coverage through beam steering, we propose a hybrid beamforming technique to elongate the depth of focus of transmit beams and a method of element selection that improves steering capabilities that take advantage of array reconfigurability using annular rings. A local minimization technique to optimize the hybrid aperture is discussed in this paper.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
April 2010
Our Bioengineering Research Partnership grant, -High Frequency Ultrasound Arrays for Cardiac Imaging", including the individuals cited at the end of this paper - Douglas N. Stephens (UC Davis), Matthew O'Donnell (UW Seattle), Kai Thomenius (GE Global Research), Aaron M. Dentinger (GE Global Research), Douglas Wildes (GE Global Research), Peter Chen (St.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
December 2008
Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias. As a result of technological advances that enable small feature sizes and a high level of integration, nonfluoroscopic intracardiac echocardiography (ICE) imaging catheters are attracting increasing attention. ICE catheters improve EP procedural guidance while reducing the undesirable use of fluoroscopy, which is currently the common catheter guidance method.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
March 2008
A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
January 2008
We have computed predistorted pulses that minimize tissue harmonics to < -25 dB compared to fundamental over a 4-cm depth in the focal region using a Hankel transform-based algorithm. The results indicate their potential in achieving patient independent improvement in contrast with microbubbles using wideband ultrasonic transducers at high mechanical indices.
View Article and Find Full Text PDF