Publications by authors named "Kagan Huysal"

Background: On an initial urine screening test for illegal substances, if the concentration of a substance is at or above the determined legislative threshold, it is reported as positive. Repeating testing with the same sample to verify it before reporting is a common practice in clinical laboratories. This study aimed to determine whether measurement uncertainty (MU) results can be used to detect a grey zone to reduce repeat testing.

View Article and Find Full Text PDF

We investigated in vitro the management of intraprocedural anticoagulation in patients requiring immediate percutaneous coronary intervention (PCI) while using regular direct oral anticoagulants (DOACs). Twenty-five patients taking 20 mg of rivaroxaban once daily comprised the study group, while five healthy volunteers included the control group. In the study group, a beginning (24 h after the last rivaroxaban dose) examination was performed.

View Article and Find Full Text PDF

Red cell distribution width (RDW) is a parameter of complete blood count (CBC). The RDW to platelet count ratio (RPR) is a new index that has been shown to reflect the severity of inflammation. We aim to determine the reference interval (RI) of RPR for premature newborns.

View Article and Find Full Text PDF

Objectives: Albumin undergoes structural changes under ischemia and oxidative stress, turning into ischemia-modified albumin (IMA). It has been proposed as an early biomarker for various diseases associated with ischemia. We aimed to investigate the relationship between serum IMA and peripheral artery disease (PAD) and whether it is a risk marker for the severity of PAD.

View Article and Find Full Text PDF

Background: The aim of this study was to examine age-related differences in hemogram parameters and hematologic inflammatory markers in pediatric patients with COVID-19.

Methods: This retrospective study included children aged 2 months to 18 years (n = 208) who have a confirmed diagnosis of COVID-19 and a control group comprising 117 healthy children between February 2021 and July 2021. The analysis of subgroup hematological values were performed according to the children's age cutoffs.

View Article and Find Full Text PDF

Objective: Semaphorin4D (Sema4D), a novel integral membrane glycoprotein, plays a role in atherosclerosis, angiogenesis and chronic inflammation. Elevated levels of sema4D were presented in myocardial infarction, heart failure and atrial fibrillation. Aim of the study was to investigate the relation between sema4D and recurrence after catheter ablation (CA) in paroxysmal AF.

View Article and Find Full Text PDF

Despite prophylactic anticoagulant treatments, thrombotic complications may develop in patients with coronavirus disease 2019 (COVID-19). This study aimed to evaluate the factors influencing anti-factor Xa activity in COVID-19 patients receiving low molecular weight heparin (LMWH). We prospectively evaluated 80 COVID-19 patients, diagnosed using polymerase chain reaction test, who were admitted to our clinic and administered LMWH; LMWH (enoxaparin) was applied according to the weight, D-dimer levels, and clinical condition of patients.

View Article and Find Full Text PDF

Glycosaminoglycans (GAGs) are sulfated, negatively charged polysaccharides produced in almost every cell of the human body. As GAGs are extracellularly localized, the changes in body fluids such as blood and urine may reflect pathological changes in the urinary system as observed in other pathologies. In this review, we determined the potential of urinary and/or serum GAG levels as a marker for kidney and urothelial system diseases.

View Article and Find Full Text PDF

Background/aim: In this study, we aimed to evaluate the initial hematological findings analyzed on admission in confirmed COVID-19 patients who were transferred to the intensive care unit (ICU), to predict possible hematological indices.

Materials And Methods: Initial neutrophil to lymphocyte ratio (NLR), platelet to lymphocyte ratio (PLR), monocyte to lymphocyte ratio (MLR), red cell distribution width to platelet ratio (RPR), mean platelet volume to platelet ratio, and lymphocyte multiplied by platelet count (LYM × PLT), of 695 patients with laboratory-confirmed COVID-19 were investigated and comparisons were made between the mild/moderate and severe groups.

Results: The proportion of COVID-19 cases admitted to the ICU was 3.

View Article and Find Full Text PDF

Background: In this study, we aimed to investigate the effects of thiol-disulfide homeostasis in patients undergoing on-pump coronary artery bypass grafting.

Methods: Between January 2018 and October 2018, a total of 51 patients (43 males, 8 females; mean age 61.8±8.

View Article and Find Full Text PDF

Background: In clinical laboratories, a common practice used to verify tests prior to reporting is repeat testing. Our objective was to evaluate the differences between the results of blood ethanol concentration (BEC) test repetitions and report on the role of repeat testing to prevent reporting of incorrect results.

Methods: We conducted a retrospective study of data retrieved from the Bursa Yuksek Ihtisas Training and Research Hospital's document management system by calculating the percentage change between repeated BEC test runs.

View Article and Find Full Text PDF

Unlabelled: The major extracellular electrolytes, sodium, and potassium are often requested together and form a large percentage of the requested tests in routine clinical chemistry laboratories. Two types of devices that use direct and indirect ion-selective electrode (ISE) methods are used in hospitals for electrolyte measurements: blood gas analyzers (BGA), which use direct ISE technology, and the indirect ISE method, which is often used in a central-laboratory autoanalyzer (AA). We aimed to summarize the current scientific knowledge based on whether the electrolyte test results, using Na and K test results obtained with BGA and an AA, can be used interchangeably.

View Article and Find Full Text PDF

Introduction: The quality of blood ethanol concentration (BEC) determination is important because of its legal ramifications. Measurement uncertainty provides quantitative information about the quality and reliability of test results. In this study, we aim to calculate the measurement uncertainty for the ethanol test in our laboratory measured with a Synchron Systems Ethanol assay kit by employing an enzymatic rate method on the Beckman-Coulter Olympus AU400 auto analyzer (Beckman Coulter Inc, Melville, USA).

View Article and Find Full Text PDF

Introduction: Electrolytes have a narrow range of biological variation and small changes are clinically significant. It is important to select the best method for clinical decision making and patient monitoring in the emergency room. The sigma metrics model provides an objective method to evaluate the performance of a method.

View Article and Find Full Text PDF

Background: Atherogenic dyslipidemia is particularly common in people with type 2 diabetes (DM2). Platelets from patients with DM2 have increased reactivity and baseline activation. The aim of the present study is to evaluate the relationship between atherogenic index and hematologic inflammatory markers and to evaluate the relationship between these parameters and associated variables in diabetic retinopathy (DR) patients.

View Article and Find Full Text PDF

Background: The level and activity of indoleamine 2,3-dioxygenase (IDO) and the concentrations of L-tryptophan and its metabolite L-kynurenine were determined in association with various renal diseases. However, there have been no data regarding these parameters in patients on peritoneal dialysis compared to those undergoing hemodialysis or kidney transplantation.

Methods: This study investigated the level and activity of IDO and determined oxidative balance by calculating the total oxidant status (TOS), total antioxidant status (TAS), and oxidative stress index (OSI).

View Article and Find Full Text PDF

Background: Intoxication due to carbon monoxide (CO) is one of the most common types of poisoning. Cardiac effects of carboxyhemoglobin (COHb) range from simple arrhythmias to myocardial infarction.

Objectives: The current study aimed to investigate the relationship between blood carboxyhemoglobin and high-sensitivity cardiac troponin T (hs-cTnT) level with a highly sensitive assay in patients with acute carbon monoxide poisoning.

View Article and Find Full Text PDF

Platelet indices (PI) -- plateletcrit, mean platelet volume (MPV) and platelet distribution width (PDW) -- are a group of derived platelet parameters obtained as a part of the automatic complete blood count. Emerging evidence suggests that PIs may have diagnostic and prognostic value in certain diseases. This study aimed to summarize the current scientific knowledge on the potential role of PIs as a diagnostic and prognostic marker in patients having emergency, non-traumatic abdominal surgery.

View Article and Find Full Text PDF

Introduction: Glucose meters are used routinely in hospital wards to manage blood glucose levels in patients requiring frequent monitoring of blood glucose.

Objective: Our institution has 50 POC instruments utilized by diverse population of all ages and medical conditions. The primary objective of our study was to investigate whether all these CareSens glucose meters (I-sense Inc, Seoul, South Korea) results in hospitalized patients during routine clinical care jointly satisfy the specified quality specifications, as defined by Clinical and Laboratory Standards Institute (CLSI) guideline POCT12-A3.

View Article and Find Full Text PDF

Introduction: Glycosylated hemoglobin (HbA1c) concentrations measured in clinical chemistry laboratories show large differences between their interlaboratory reported values. Laboratory measurements of quality performance should be based on quantitative data. The sigma metrics model provides an objective method for the assessment of current HbA1c assays and is useful in quality management planning.

View Article and Find Full Text PDF

Background: In heart failure patients, mean platelet volume (MPV) may reflect increased platelet activation or increased numbers of large, hyper-aggregable platelets. B-type natriuretic peptide (BNP) concentration in blood is a sensitive and specific marker of heart failure, correlating with the severity and prognosis of illness, in patients presenting with acute dyspnea to the emergency department. This study evaluated the correlation between BNP concentration and MPV.

View Article and Find Full Text PDF

Background: The antioxidant melatonin effectively scavenges highly toxic hydroxyl radicals. Decreases in circulating melatonin levels have been reported in patients with diseases that become more serious with advancing age. The purpose of the present study was to explore the relationship between circulatory melatonin level and the extent of senile cataracts.

View Article and Find Full Text PDF

Introduction: Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures.

View Article and Find Full Text PDF

Background: In our emergency department, we collect blood in Rapid Serum Tubes (RSTs; Becton Dickinson, Franklin Lakes, NJ), in which clotting times are reduced. We investigated the influence of RST use on cardiac troponin T (hs-cTnT) and creatine kinase-MB (CK-MB) test results, in comparison with the use of tubes featuring a separator gel containing a clotting activator (SSTs; Green-vac, Yongin, Korea).

Methods: Samples from 60 patients were divided into equal aliquots and placed into RSTs and SSTs; hs-cTnT and CK-MB concentrations were determined using an autoanalyzer (Elecsys 2010) running commercial assays (Roche Diagnostics, Penzberg, Germany).

View Article and Find Full Text PDF

Background: Electrolyte values are measured in most critically ill intensive care unit (ICU) patients using both an arterial blood gas analyzer (ABG) and a central laboratory auto-analyzer (AA). The aim of the present study was to investigate whether electrolyte levels assessed using an ABG and an AA were equivalent; data on sodium and potassium ion concentrations were examined.

Methods: We retrospectively studied patients hospitalized in the ICU between July and August 2011.

View Article and Find Full Text PDF