Publications by authors named "Kado Y"

Article Synopsis
  • * The patient had issues with his artificial aortic valve leading to severe stenosis, while his prosthetic mitral valve showed mild problems, prompting the fifth surgery to replace the aortic valve with a new bioprosthetic valve.
  • * The report emphasizes the importance of managing eosinophil levels before and after surgery, alongside careful selection of artificial valves, to enhance treatment outcomes for patients with HES and related heart valve diseases.
View Article and Find Full Text PDF

The steady propagation of a (d-1)-dimensional planer interface in d-dimensional space is studied by analyzing mesoscopic nonconserved order parameter dynamics with two local minima under the influence of thermal noise. In this analysis, an entropic force generating interface propagation is formulated using a perturbation method. It is found that the entropic force singularly depends on an ultraviolet cutoff when d≥2.

View Article and Find Full Text PDF

Objective: Acute myeloid leukemia (AML) is the most common form of leukemia among adults in Japan. This study aimed to understand the treatment patterns, health care resource utilization, and costs of FMS-like tyrosine kinase 3 mutation-positive (FLT3m+) AML patients in Japan.

Methods: A retrospective cohort study of Japanese FLT3m + AML patients was conducted using data extracted from a national hospital-based claims database provided by Medical Data Vision Co.

View Article and Find Full Text PDF

Background: The long-term mortality of end-stage renal disease (ESRD) patients is still unsatisfactory. Therefore, long-term risk assessments in ESRD patients undergoing cardiac surgery are needed. Recently, sarcopenia is major concern in cardiac surgery because of its association with poor long-term survival.

View Article and Find Full Text PDF

Background: Cardiac hemangiomas are rare, accounting for only 5% of benign cardiac tumors. In the past, there have been few reports of giant cardiac hemangiomas that were > 100 mm in size but were asymptomatic.

Case Presentation: A 44-year-old woman presented with a large asymptomatic intracardiac mass that was accidentally detected on echocardiography.

View Article and Find Full Text PDF

Minamata disease, which happened during the 1950s and 1960s in Minamata, Japan, is a well-known case of food poisoning caused by methylmercury-contaminated fish. Although many children were born, in the affected areas, with severe neurological signs after birth (known as congenital Minamata disease (CMD)), few studies have explored the possible effects of low-to-moderate methylmercury exposure in utero, probably at lower levels than in CMD patients, in Minamata. We, therefore, recruited 52 participants in 2020: 10 patients with known CMD; 15 moderately exposed residents; and 27 non-exposed controls.

View Article and Find Full Text PDF

Our synbiotics ( strain Shirota, strain Yakult, and galacto-oligosaccharides: LBG) helps mitigate serious adverse events such as febrile neutropenia (FN) and diarrhoea in oesophageal cancer patients receiving neoadjuvant chemotherapy (NAC). Unfortunately, LBG therapy does not benefit all patients. Identification of the gut microbiota species involved in adverse events during chemotherapy could help predict the onset of adverse events.

View Article and Find Full Text PDF

With the development of practical thin-film batteries, multilayer graphene (MLG) is being actively investigated as an anode material. Therefore, research on determining a technique to fabricate thick MLG on arbitrary substrates at low temperatures is essential. In this study, we formed an MLG with controlled thickness at low temperatures using a layer exchange (LE) technique and evaluated its anode properties.

View Article and Find Full Text PDF

Antigen carriers that can selectively deliver antigens to antigen presenting cells and which can simultaneously activate these cells (adjuvant property) are necessary for efficient cancer immunotherapy or vaccination. Delivery of a model antigen into dendritic cell cytosol has been achieved by pH-responsive polymer-modified liposomes via destabilization of endosomal membranes responding to acidic pH, which impelled antigen-specific cellular immunity. Furthermore, β-glucan-based pH-responsive polysaccharides have shown not only cytosolic antigen delivery performance but also adjuvant property, which further heightened cellular immune responses.

View Article and Find Full Text PDF

SiGe is a promising anode material for replacing graphite in next generation thin-film batteries owing to its high theoretical charge/discharge capacity. Metal-induced layer exchange (LE) is a unique technique used for the low-temperature synthesis of SiGe layers on arbitrary substrates. Here, we demonstrate the synthesis of SiGe (x = 0-1) layers on plastic films using Al-induced LE.

View Article and Find Full Text PDF

The S2 alar-iliac screw (S2AIS) is commonly used for long spinal fusion as a rigid distal foundation in spinal deformity surgeries, and it is also used in percutaneous sacropelvic fixation for providing an in-line connection to the proximal spinal constructs without using offset connectors. Although the pelvic shape is different between males and females, reports on S2AIS trajectories according to gender have been scarce in the literature. In this paper, S2AIS trajectories are compared between males and females using pelvic three-dimensional computed tomography (3D-CT) in a normal Japanese population.

View Article and Find Full Text PDF

To estimate the health-promoting effects of (previously ) strain Shirota (LcS) that reached the lower gastrointestinal tract alive, we investigated the characteristics of gut microbiome, organic acid profiles, defecatory symptoms and serum viral antibody indexes of healthy Japanese adults between the group in whom live LcS was detected or not from stool. The β-diversity index of the gut microbiome constituted a significant difference between the live-LcS-detected-group (LLD) and the live-LcS-not-detected-group (LLnD). In the LLD, the , and counts were significantly higher, and the succinate concentration was significantly lower than that in the LLnD.

View Article and Find Full Text PDF

For (PA), infection control and appropriate antimicrobial treatment have become important issues. Diagnosis is critical in managing PA infection, but conventional methods are not highly accurate or rapid. We developed a new PA quantification system based on 23S rRNA-targeted reverse transcription quantitative PCR (RT-qPCR).

View Article and Find Full Text PDF

Background And Hypothesis: It is generally considered that fragment fixation with bone pegs (FFBP) for osteochondritis dissecans (OCD) of the humeral capitellum can be indicated for stages I and II according to the International Cartilage Repair Society (ICRS) classification of OCD and it is difficult to obtain complete bone union for advanced lesions. However, the clinical and radiologic results of FFBP with cancellous bone graft for ICRS-OCD stage III with lateral wall involvement have not been described in detail. Good bone union can be achieved with the lateral wall fragment of the capitellum by FFBP in combination with refreshing the sclerotic surface at the base of the lesion and cancellous bone grafting even in ICRS-OCD stage III lesions.

View Article and Find Full Text PDF

We are developing a new left atrial assist device (LAAD) for patients who have heart failure with preserved ejection fraction (HFpEF). This study aimed to assess the hemodynamic effects of the LAAD under both normal heart conditions and various diastolic heart failure (DHF) conditions using a mock circulatory loop. A continuous-flow pump that simulates LAAD, was placed between the left atrial (LA) reservoir and a pneumatic ventricle that simulated a native left ventricle on a pulsatile mock loop.

View Article and Find Full Text PDF

We are developing a left atrial assist device (LAAD) to pump blood from the left atrium to the left ventricle for patients who have heart failure with preserved ejection fraction (HFpEF). This study aimed to assess the hemodynamics with the LAAD implanted at two different levels: the mitral valve (MV) level, after removing the MV; and the supravalvular level, preserving MV function conditions using an in vitro mock circulatory loop. Normal heart and mild, moderate, and severe diastolic heart failure conditions were simulated, and the LAAD was set at three different speeds.

View Article and Find Full Text PDF

Although diet is an important factor influencing gut microbiota, there are very few studies regarding that relationship in Japanese people. Here, we analyzed the relationship between habitual dietary intake surveyed by food frequency questionnaire and the quantitative features of gut bacteria by quantitative PCR and next generation sequencer in 354 healthy Japanese adults. The α-diversity of gut microbiota was positively correlated with the intake of mushrooms and beans and negatively correlated with the intake of grains.

View Article and Find Full Text PDF

Long-term combination treatment with lenalidomide and low-dose dexamethasone is important to achieve a curative effect in patients with multiple myeloma (MM). In this study, the plasma concentration of lenalidomide was measured at 3 h after oral administration, when the drug is in the elimination phase and can be easily measured in outpatients, to identify factors that may lead to the discontinuation of this combination therapy. Patients were assigned to continuation or discontinuation of therapy groups, and the baseline characteristics of patients, lenalidomide concentration, and concentration/dose (C/D) ratios reflecting oral clearance were compared between the two groups.

View Article and Find Full Text PDF

Background: The Advanced ventricular assist device (Advanced VAD) is designed as a universal pump intended to prevent backflow in the event of pump stoppage, to maintain physiological pulse pressure, and to be used as both a left and right VAD. The purpose of this study was to evaluate the performance of the Advanced VAD as both a left and right VAD in an acute in vivo study in calves.

Methods: The Advanced VAD was implanted through a median sternotomy in 5 healthy calves (weight, 71.

View Article and Find Full Text PDF

Biventricular assist device (BVAD) implantation is the treatment of choice in patients with severe biventricular heart failure and cardiogenic shock. Our team has developed a miniaturized continuous flow, double-ended centrifugal pump intended for total artificial heart implant (CFTAH). The purpose of this initial in vivo study was to demonstrate that the scaled-down CFTAH (P-CFTAH) can be appropriate for BVAD support.

View Article and Find Full Text PDF

An advanced ventricular assist device (VAD), which is under development in our institution, has specific features that allow changes in the axial rotor position and pump performance by intrapump pressure difference. However, performance could be influenced by the pump orientation because of the effect of gravity on the rotor position. The purpose of this study was to evaluate the effects of pump orientation on the pump performance, including pulse pressure and regurgitant flow through the pump when the pump was stopped.

View Article and Find Full Text PDF

Background: The intestinal epithelial barrier allows absorption of dietary nutrients and prevents passage of pathogens and toxins into the body. Severe insults have a negative impact on the intestinal environment, which may decrease intestinal barrier function and cause bacterial translocation. Bacterial translocation, which can cause infectious complications, is defined as the passage of microbes from the gastrointestinal tract across the mucosal barrier to extraintestinal sites.

View Article and Find Full Text PDF

Objectives: Many patients with heart failure have preserved ejection fraction but also diastolic dysfunction, with no effective therapy. We are developing a new pump (left atrial assist device, LAAD) for implantation at the mitral position to pump blood from the left atrium to sufficiently fill the left ventricle. The purpose of the initial in vitro study was to demonstrate that the LAAD can reduce left atrial pressure (LAP) and increase cardiac output (CO) while maintaining arterial pulsatility and normal aortic valve function using a proof-of-concept device.

View Article and Find Full Text PDF

We are developing a novel type of miniaturized left ventricular assist device that is configured for transapical insertion. The aim of this study was to assess the performance and function of a new pump by using a Virtual Mock Loop system for device characterization and mapping. The results, such as pressure-flow performance curves, from pump testing in a physical mock circulatory loop were used to analyze its function as a left ventricular assist device.

View Article and Find Full Text PDF

This study aimed to evaluate a newly designed circulatory mock loop intended to model cardiac and circulatory hemodynamics for mechanical circulatory support device testing. The mock loop was built with dedicated ports suitable for attaching assist devices in various configurations. This biventricular mock loop uses two pneumatic pumps (Abiomed AB5000, Danvers, MA, USA) driven by a dual-output driver (Thoratec Model 2600, Pleasanton, CA, USA).

View Article and Find Full Text PDF