The aim of this study was to find the effect of transmural pressure on the determination of the photoplethysmographic (PPG) waveform arterial stiffness index (PPGAI). The study was conducted on 51 subjects without diagnosis of cardiovascular disease, aged between 24 and 74 years. The relation between the transmural pressure, which is the difference between the arterial blood pressure and the PPG sensor contact pressure, and the PPGAI was determined.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2023
Patients with chronic kidney disease (CKD) are at higher cardiovascular risk than the general population. Cardiovascular diseases, vascular calcification among them, are the leading cause of death in these patients. Factors influencing vascular calcification are oxidative stress, inflammation, and accumulation of uremic toxins during CKD.
View Article and Find Full Text PDFBackground: Kt/V is the most used marker to estimate dialysis adequacy; however, it does not reflect the removal of many other uraemic toxins, and a new approach is needed. We have assessed the feasibility of estimating intradialytic serum time-averaged concentration (TAC) of various uraemic toxins from their spent dialysate concentrations that can be estimated non-invasively online with optical methods.
Methods: Serum and spent dialysate levels and total removed solute (TRS) of urea, uric acid (UA), indoxyl sulphate (IS) and β2-microglobulin (β2M) were evaluated with laboratory methods during 312 haemodialysis sessions in 78 patients with four different dialysis treatment settings.
Optical online methods are used to monitor the haemodialysis treatment efficiency of end stage kidney disease (ESKD) patients. The aim of this study was to analyse the effect of the administration of UV-absorbing drugs, such as paracetamol (Par), on the accuracy of optical monitoring the removal of uremic toxins uric acid (UA) and indoxyl sulfate (IS) during standard haemodialysis (HD) and haemodiafiltration (HDF) treatments. Nine patients received Par in daily dosages 1−4 g for 30 sessions.
View Article and Find Full Text PDFPhotoplethysmography is now widely utilised by clinical devices such as pulse oximeters, and wearable devices such as smartwatches. It holds great promise for health monitoring in daily life. This editorial considers whether it would be possible and beneficial to establish best practices for photoplethysmography signal acquisition and processing.
View Article and Find Full Text PDF