Olecranon fractures are most frequently stabilized by tension band wiring (TBW), which unfortunately leads to relevant implant removal rates due to K-wire migration and soft tissue irritation. As lag screw osteosynthesis (LSO) might be a gentle and effective alternative in simple fracture patterns, the goal of the present study was to biomechanically compare LSO with TBW in simple olecranon fractures at a cadaver model. A simple olecranon fracture (Mayo type IIA) was created in eight pairs of human cadaver elbows, which were pairwise fixed by either TBW or two transcortical 4.
View Article and Find Full Text PDFBackground: In the treatment of unstable olecranon fractures, anatomically preshaped locking plates exhibit superior biomechanical results compared with tension band wiring. However, posterior plating (PP) still is accompanied by high rates of plate removal because of soft-tissue irritation and discomfort. Meanwhile, low-profile plates precontoured for collateral double plating (DP) are available and enable muscular soft-tissue coverage combined with angular-stable fixation.
View Article and Find Full Text PDFBackground: Biodegradable implants have gained increasing importance for the fixation of simple displaced radial head fractures to supersede implant removal and to minimize cartilage destruction. Commonly used polylactide pins still lead to higher rates of secondary loss of reduction compared with metal implants. Alternatively, implants made from a magnesium alloy meanwhile are available in a pin design that hypothetically could perform better than polylactide pins.
View Article and Find Full Text PDFBackground: Displaced fractures of the humeral capitellum are commonly treated operatively and fixed by titanium screws (TSs) either directly or indirectly. In the case of direct transcartilaginous fixation, biodegradable screws with the ability to be countersunk can be favorable regarding implant impingement and cartilage destruction. Hence, the goal of this study was to biomechanically compare headless compression screws made from titanium with a biodegradable equivalent made from a magnesium alloy.
View Article and Find Full Text PDFFor radial head osteosynthesis, biodegradable implants are gaining in importance to minimize cartilage destruction and implant impingement and to supersede implant removal. Since loss of reduction and pseudarthrosis remain challenging complications, new implants should at least provide comparable biomechanical properties as commonly used metal implants. The objective of this study was to compare the treatment by polylactide pins to titanium screws and to quantify the produced cartilage defects.