Objectives: To assess the metal artifact reductions of dual-energy computed tomography (DECT) high-energy virtual monochromatic images (VMI) combined with the single energy metal artifact reduction (SEMER) (CANON MEDICAL SYSTEMS, Otawara, Japan) processing techniques for iodine (I)-125 seed identification in postimplant computed tomography (CT) after prostate brachytherapy.
Methods: Dual-energy acquisition with fast tube voltage switching was performed on a prostate phantom with simulated seeds and six clinical cases treated with I-125 prostate brachytherapy. The images were retrospectively reconstructed at VMI energy levels of 65-200 keV and with and without SEMAR (SEMAR and non-SEMAR images).
[Purpose] Extant techniques for palpating nodules, a diagnostic criterion of myofascial trigger points, lack high reliability. Therefore, this study aimed to investigate the effects of training and practice using a novel muscle-nodule-palpation simulator. [Participants and Methods] Sixteen university students (age range: 19-22 years) were randomly assigned to the training (=8) and control (=8) groups and used the muscle-nodule-palpation simulator to determine the position and orientation of the muscle nodule embedded in the model.
View Article and Find Full Text PDFThis case report highlights the rare occurrence of Wernicke encephalopathy caused by malnutrition in a depressed patient with atypical imaging findings. A 60-year-old female with depression developed a disturbance of consciousness owing to Wernicke encephalopathy. Magnetic resonance imaging showed abnormal signals in the thalamus and mammillary bodies around the third ventricle, cerebral aqueduct, and fourth ventricle.
View Article and Find Full Text PDFSolid refrigerants exhibiting a caloric effect upon applying external stimuli are receiving attention as one of the next-generation refrigeration technologies. Herein, we report a new inorganic refrigerant, rubidium cyano-bridged manganese-iron-cobalt ternary metal assembly (cyano-RbMnFeCo). Cyano-RbMnFeCo shows a reversible barocaloric effect with large reversible adiabatic temperature changes of 74 K (from 57 °C to -17 °C) at 340 MPa, and 85 K (from 88 °C to 3 °C) at 560 MPa.
View Article and Find Full Text PDFThis paper proposes a new optical biosensor composed of a silicon-on-insulator (SOI) p-n junction photodiode (PD) with a surface plasmon (SP) antenna. When the phase-matching condition between two lateral wavelengths of the diffracted light from the SP antenna and the waveguiding mode in the SOI PD is satisfied, we observe sharp peaks in the spectroscopic light sensitivity. Since the peak wavelength depends on the RI change around the SP antenna corresponding to the phase-matching condition, the SOI PDs with an SP antenna can be applied to the optical biosensor.
View Article and Find Full Text PDF