A series of 716 children underwent 2065 cerebrospinal fluid shunt procedures. Shunt failure due to fracture of the peripheral drain occurred 60 times, 38 times in ventriculo-atrial and 22 times in ventriculo-peritoneal shunts. The break occurred most commonly 2-4 cm above the neck incision in cardiac and just cephalad to the clavicle in abdominal drains.

View Article and Find Full Text PDF

During the years from 1965 to 1986, 716 children underwent a total of 2065 shunt procedures in our department. Of these, 1298 were ventriculoatrial (VA). Until 1979, Pudenz VA shunts were almost exclusively used as the primary procedure as well as in revisions.

View Article and Find Full Text PDF

Shunt failure due to collapse of the Mini-Holter valve was observed 13 times in 11 out of 179 children with an implanted Mini-Holter ventriculo-peritoneal (VP) or ventriculo-atrial (VA) shunt during a 10 year period. Intussusception of the proximal or distal end of the valve thus caused a shunt failure rate of 6% of the children in this series. Two children experienced this complication twice.

View Article and Find Full Text PDF

We present 36 consecutive patients with intrinsic glioma of the pons. Tumors with exophytic expansion were excluded. There were 16 females and 20 males, ranging in age from 2 to 13 years, median 6 years.