Publications by authors named "K H Bhimani"

The instability of Nickel (Ni)-rich cathodes at high voltage is a critical bottleneck toward developing superior lithium-ion batteries. This instability is driven by cathode-electrolyte side reactions, causing rapid degradation, and compromising the overall cycle life. In this study, a protective coating using dispersed "magnetite (FeO.

View Article and Find Full Text PDF

With excellent energy resolution and ultralow-level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos ν_{s}→ν_{a}. We report new limits on fermionic dark matter absorption (χ+A→ν+A) and sub-GeV DM-nucleus 3→2 scattering (χ+χ+A→ϕ+A), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons).

View Article and Find Full Text PDF

^{180m}Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower-energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter, and K-spin violation.

View Article and Find Full Text PDF

Exact p-value (XPV)-based methods for dot product-like score functions-such as the XCorr score implemented in Tide, SEQUEST, Comet or shared peak count-based scoring in MSGF+ and ASPV-provide a fairly good calibration for peptide-spectrum-match (PSM) scoring in database searching-based MS/MS spectrum data identification. Unfortunately, standard XPV methods, in practice, cannot handle high-resolution fragmentation data produced by state-of-the-art mass spectrometers because having smaller bins increases the number of fragment matches that are assigned to incorrect bins and scored improperly. In this article, we present an extension of the XPV method, called the high-resolution exact p-value (HR-XPV) method, which can be used to calibrate PSM scores of high-resolution MS/MS spectra obtained with dot product-like scoring such as the XCorr.

View Article and Find Full Text PDF

Introduction: Traditionally, sutures have been widely used to close intraoral wounds. Various alternatives have been developed amongst which newer tissue adhesives such as N-butyl-2-cyanoacrylate having accepted clinical properties are gaining popularity. The primary purpose of the present study is to evaluate the efficacy of N-butyl-2-cyanoacrylate for intraoral attached mucosal wound closure following alveoloplasty.

View Article and Find Full Text PDF