Non-enzymatic glucose sensing is a crucial field of study because of the current market demand. This study proposes a novel design of glucose sensor with enhanced selectivity and sensitivity by using graphene Schottky diodes, which is composed of graphene (G)/platinum oxide (PtO)/n-silicon (Si) heterostructure. The sensor was tested with different glucose concentrations and interfering solutions to investigate its sensitivity and selectivity.
View Article and Find Full Text PDFBiochem Biophys Res Commun
July 2019
Carbon nanotubes (CNTs) are a class of carbon based nanomaterials which have attracted substantial attention in recent years as they exhibit outstanding physical, mechanical and optical properties. In the last decade many studies have emerged of the underlying mechanisms behind CNT toxicity including malignant transformation, the formation of granulomas, inflammatory responses, oxidative stress, DNA damage and mutation. In the present investigation, we studied the biodegradation of single-walled carbon nanotubes (SWCNTs) by Cytochrome P450 enzymes (CYP3A4) through using Raman spectroscopy.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2018
The electrical contact resistance at metal-graphene interfaces can significantly degrade the properties of graphene devices and is currently hindering the full exploitation of graphene's potential. Therefore, the influence of environmental factors, such as humidity, on the metal-graphene contact resistance is of interest for all graphene devices that operate without hermetic packaging. We experimentally studied the influence of humidity on bottom-contacted chemical-vapor-deposited (CVD) graphene-gold contacts, by extracting the contact resistance from transmission line model (TLM) test structures.
View Article and Find Full Text PDFWe demonstrate humidity sensing using a change of the electrical resistance of single-layer chemical vapor deposited (CVD) graphene that is placed on top of a SiO2 layer on a Si wafer. To investigate the selectivity of the sensor towards the most common constituents in air, its signal response was characterized individually for water vapor (H2O), nitrogen (N2), oxygen (O2), and argon (Ar). In order to assess the humidity sensing effect for a range from 1% relative humidity (RH) to 96% RH, the devices were characterized both in a vacuum chamber and in a humidity chamber at atmospheric pressure.
View Article and Find Full Text PDFManufacturing defects of endotracheal tube (ETT) are still encountered in anesthesia practice. Many such defects go unnoticed during routine inspection prior to their use. Such defects in ETT may lead to partial or complete airway obstruction in an intubated patient.