Despite promising advances with metal-organic frameworks (MOFs) as stationary phases for chromatography, the application of MOFs for one- and two-dimensional micro-gas chromatography (μGC and μGC × μGC) applications has yet to be shown. We demonstrate for the first time, μGC columns coated with two different MOFs, HKUST-1 and ZIF-8, for the rapid separation of high volatility light alkane hydrocarbons (natural gas) and determined the partition coefficients for toxic industrial chemicals, using μGC and μGC × μGC systems. Complete separation of natural gas components, methane through pentane, was completed within 1 min, with sufficient resolution to discriminate n-butane from i-butane.
View Article and Find Full Text PDFA small, consumable-free, low-power, ultra-high-speed comprehensive GC×GC system consisting of microfabricated columns, nanoelectromechanical system (NEMS) cantilever resonators for detection, and a valve-based stop-flow modulator is demonstrated. The separation of a highly polar 29-component mixture covering a boiling point range of 46 to 253 °C on a pair of microfabricated columns using a Staiger valve manifold in less than 7 seconds, and just over 4 seconds after the ensemble holdup time is demonstrated with a downstream FID. The analysis time of the second dimension was 160 ms, and peak widths in the second dimension range from 10-60 ms.
View Article and Find Full Text PDFWe describe for the first time hydrogen bonded acid (HBA) polymer, poly{methyl[3-(2-hydroxyl, 4,6-bistrifluoromethyl)phenyl]propylsiloxane}, (DKAP), as stationary phase for gas chromatography (μGC) of organophosphate (OP), chemical warfare agent (CWA) surrogates, dimethylmethylphosphonate (DMMP), diisopropylmethylphosphonate (DIMP), diethylmethylphosphonate (DEMP), and trimethylphosphate (TMP), with high selectivity. Absorption of OPs to DKAP was one-to-several orders of magnitude higher relative to commercial polar, mid-polar, and nonpolar stationary phases. We also present for the first-time thermodynamic studies on the absorption of OP vapors and quantitative binding energy data for interactions with various stationary phases.
View Article and Find Full Text PDFColloids Surf B Biointerfaces
November 2017
Controlling the traffic of molecules and ions across membranes is a critical feature in a number of biologically relevant processes and highly desirable for the development of technologies based on membrane materials. In this paper, ion transport behavior of hybrid lipid/polymer membranes was studied in the absence and presence of ion transfer agents. A pH-sensitive fluorophore was used to investigate ion (H/OH) permeability across hybrid lipid/polymer membranes as a function of the fraction of amphiphilic block copolymer.
View Article and Find Full Text PDFFragrances and malodors are ubiquitous in the environment, arising from natural and artificial processes, by the generation of volatile organic compounds (VOCs). Although VOCs constitute only a fraction of the metabolites produced by an organism, the detection of VOCs has a broad range of civilian, industrial, military, medical, and national security applications. The VOC metabolic profile of an organism has been referred to as its 'volatilome' (or 'volatome') and the study of volatilome/volatome is characterized as 'volatilomics', a relatively new category in the 'omics' arena.
View Article and Find Full Text PDF