It is unclear whether sexual well-being, which is an important part of individual and relational health, may be at risk for declines after a pregnancy loss given the limits of prior work. Accordingly, in a cross-sectional study, we used structural equation modeling to (1) compare sexual well-being levels-satisfaction, desire, function, distress, and frequency-of both partners in couples who had experienced a pregnancy loss in the past four months (N = 103 couples) to their counterparts in a control sample of couples with no history of pregnancy loss (N = 120 couples), and (2) compare sexual well-being levels of each member of a couple to one another. We found that gestational individuals and their partners in the pregnancy loss sample were less sexually satisfied than their control counterparts but did not differ in sexual desire, problems with sexual function, nor sexual frequency.
View Article and Find Full Text PDFWe report a study on the performance limits of stabilized optical frequency combs from semiconductor mode-locked diode lasers. Operating characteristics such as the number of comb lines, comb tooth linewidth, the physical parameters that affect the independent control of pulse repetition rate and offset frequency, and the potential for self-stabilization, are explored.
View Article and Find Full Text PDFAn optical frequency comb with mode spacing of 10 GHz operating in the c-band is produced from a harmonically mode-locked laser using a slab-coupled optical waveguide amplifier device with a fiber-coupled external cavity. An intracavity Fabry-Perot etalon serves as a high finesse optical filter for supermode suppression and as the reference for cavity length stabilization using a multi-combline Pound-Drever-Hall setup. The Allan deviation of a single optical combline near 193.
View Article and Find Full Text PDFAn optical frequency comb is constructed using a semiconductor gain medium with a fiber-coupled external cavity and stabilized to an intracavity 10,000 finesse etalon, which is temperature stabilized and held in a vacuum chamber at 10(-6) Torr. Optical frequency stability measurements show that the comb has a reduced sensitivity to environmental fluctuations. An upper limit on the optical frequency variation of 100 kHz over >12 min of continuous operation is measured using a real-time spectrum analyzer.
View Article and Find Full Text PDFCancer J Sci Am
September 1997
Purpose: To present tolerance and toxicity information on previously untreated high-risk early-stage and advanced-stage primary epithelial ovarian cancer patients treated with adjuvant 3-hour paclitaxel and carboplatin.
Patients And Methods: Consecutive patients with high-risk early-stage and advanced-stage epithelial ovarian cancer underwent maximal surgical debulking and/or staging. Paclitaxel (175 mg/m2) was infused over 3 hours followed by a 30-minute carboplatin infusion (area under the plasma concentration time curve = 7.