IEEE Trans Ultrason Ferroelectr Freq Control
October 2012
Polyvinylidene fluoride (PVDF) is a ferroelectric polymer with unique properties suitable for use in a wide range of medical and biological imaging applications. Most notable among these is its low acoustic impedance, which matches that of the body reasonably well, and its flexible mechanical properties. This paper traces the exploitation of PVDF as a transducer material from its early beginnings for thyroid and breast imaging to its current well-established applications in ultrasound biomicroscopy.
View Article and Find Full Text PDFMaking fine scale (< 20 microm) piezoelectric composites for high frequency (> 50 MHz) ultrasound transducers remains challenging. Interdigital phase bonding (IPhB), described in this paper, presents a new technique developed to make piezoelectric composites at the ultrafine scale using a conventional dicing saw. Using the IPhB technique, a composite structure with a pitch that is less than the dicing saw blade thickness can be created.
View Article and Find Full Text PDFObjective: To evaluate high frequency (40 MHz) B-mode ultrasound for the detection of osteoarthritis (OA) lesions of varying severity in an animal model of OA.
Design: Ultrasound biomicroscopy (UBM) was performed on the femoral articular surface of adult rabbits with unilateral transection of the anterior cruciate ligament at 4, 8 and 12 weeks post-surgery and on control rabbits. The articular cartilage was examined and graded macroscopically and histologically for OA lesions.
We report here on the design and evaluation of the first high-frequency ultrasound (US) imaging system specifically designed for microimaging of the mouse. High-frequency US or US biomicroscopy (UBM) has the advantage of low cost, rapid imaging speed, portability and high resolution. In combination with the ability to provide functional information on blood flow, UBM provides a powerful method for the investigation of development and disease models.
View Article and Find Full Text PDFA new multifrequency (19-55 MHz) ultrasound biomicroscope with two-dimensional imaging and integrated Doppler ultrasound was evaluated using phantoms and isoflurane-anesthetized mice. Phantoms revealed the biomicroscope's lateral resolution was between 50 and 100 microm, whereas that of a conventional 13 MHz ultrasound system was 200-500 microm. This difference was apparent in the markedly higher resolution images achieved using the biomicroscope in vivo.
View Article and Find Full Text PDF