The aim of the present study was to determine, if bioactive glass (BG) surface inlays improve osseointegration of titanium implants in the proximal femur of adult sheep. In simulation of uncemented primary stems (nine animals), only the proximal part of the implants was grit-blasted and three surface slots of the grit-blasted region were filled with sintered BG microspheres. Primary stems were implanted using press-fit technique.
View Article and Find Full Text PDFBackground And Purpose: Antibiotic-releasing bioresorbable implants are used for local treatment of bone infections, but most drug delivery systems release antibiotic for too short a time.
Methods: We used pellets (0.9 x 1.
The use of local antibiotics from a biodegradable implant is appealing concept for treatment of chronic osteomyelitis. Our aim was to develop a new drug delivery system based on controlled ciprofloxacin release from poly(D/L-lactide). Cylindrical composite pellets (1.
View Article and Find Full Text PDFThe concept of local antibiotic delivery via biodegradable bone defect fillers with multifunctional properties for the treatment of bone infections is highly appealing. Fillers can be used to obliterate surgical dead space and to provide targeted local bactericidal concentrations in tissue for extended periods. Eventually, the osteoconductive component of the filler could guide the healing of the bone defect.
View Article and Find Full Text PDFUnlabelled: PET using (18)F-FDG is a promising imaging modality for bone infections, based on intensive consumption of glucose by mononuclear cells and granulocytes. The method may have limitations in distinguishing uncomplicated bone healing from osteomyelitis. Bone healing involves an inflammatory phase that represents a highly activated state of cell metabolism and glucose consumption, mimicking infection on PET images.
View Article and Find Full Text PDFRadiostereometric analysis (RSA) has become one of the recommended techniques for pre-market evaluation of new joint implant designs. In this study we evaluated the effect of repositioning of X-ray tubes and phantom model on the precision of the RSA method. In precision measurements, we utilized mean error of rigid body fitting (ME) values as an internal control for examinations.
View Article and Find Full Text PDFA novel chemical etching method was recently developed to create a controlled microrough surface on porous bioactive glass implants. Our earlier in vitro studies showed enhanced attachment of osteoblast-like MG63 cells on a microrough bioactive glass surface. The purpose of our current study was to confirm the in vivo significance of surface microroughening for bone bonding of bioactive glass.
View Article and Find Full Text PDF