Publications by authors named "Jussi Haikarainen"

Easyhaler (registered trademark by Orion Corporation) is a multidose dry powder inhaler (DPI) for the treatment of asthma and chronic obstructive pulmonary disease (COPD), designed to be simple and easy to use. Salmeterol-fluticasone propionate (S-F) Easyhaler (50/250 and 50/500 μg per dose), available in several European countries, provides combined inhaled corticosteroid and long-acting beta agonist therapy for the management of asthma and COPD. A requirement of the European Committee for Medical Products for Human Use guidelines is to demonstrate product performance under conditions that mimic real-life patient use.

View Article and Find Full Text PDF

Use of drug delivery devices between nebulizers, dry powder inhalers (DPIs), or metered dose inhalers (MDIs), for treating patients with asthma and chronic obstructive pulmonary disease (COPD), is based on patients' capability of coordinating the inhalation maneuver and achieving sufficient airflow. There are limited data available with regard to how patients meet the requirements of successful inhalation performance, and how the concept of inspiratory lungpower could be applied. The aim of this work was to study the patient inspiratory airflow profile performance in large data sets.

View Article and Find Full Text PDF

Background: The Easyhaler device-metered dry powder inhaler containing Salmeterol and Fluticasone propionate (S/F) has been developed for the treatment of patients with asthma and chronic obstructive pulmonary disease (COPD). We report two studies which evaluated the in vitro flow rate dependence of delivered dose (DD) and fine particle dose (FPD) of S/F Easyhaler versus Seretide Diskus.

Methods: A randomized controlled trial (RCT) assessed inspiratory flow parameters of S/F Easyhaler and Seretide Diskus in subgroups of patients with asthma (children, adolescents and adults, and elderly) and in COPD patients.

View Article and Find Full Text PDF

Budesonide Easyhaler® multidose dry powder inhaler is approved for the treatment of asthma. Objectives were to determine the delivered dose (DD) uniformity of budesonide Easyhaler® in simulated real-world conditions and with different inspiration flow rates (IFRs). Three dose delivery studies were performed using 100, 200, and 400 µg/dose strengths of budesonide.

View Article and Find Full Text PDF

Background: Easyhaler(®) device-metered dry powder inhaler containing budesonide and formoterol fumarate dihydrate (hereafter formoterol) for the treatment of asthma and chronic obstructive pulmonary disease has been developed. The current approvals of the product in Europe were based on several pharmacokinetic (PK) bioequivalence (BE) studies, and in vitro-in vivo correlation (IVIVC) modeling.

Methods: Four PK studies were performed to compare the lung deposition and total systemic exposure of budesonide and formoterol after administration of budesonide/formoterol Easyhaler and the reference product, Symbicort Turbuhaler.

View Article and Find Full Text PDF

Background: The Easyhaler(®) (EH) device-metered dry powder inhaler containing budesonide and formoterol is being developed for asthma and chronic obstructive pulmonary disease (COPD). As a part of product optimization, a series of in vitro and in vivo studies on flow rate dependency were carried out.

Methods: Inspiratory flow parameters via EH and Symbicort(®) Turbuhaler(®) (TH) inhalers were evaluated in 187 patients with asthma and COPD.

View Article and Find Full Text PDF