Publications by authors named "Jurg Sommer"

The reproductive number in Switzerland was between 1.5 and 2 during the first third of March, and has consistently decreased to around 1. After the announcement of the latest strict measure on 20 March 2020, namely that gatherings of more than five people in public spaces are prohibited, the reproductive number dropped significantly below 1; the authors of this study estimate the reproductive number to be between 0.

View Article and Find Full Text PDF

Introduction: Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity assays used in clinical haemostasis laboratories for the measurement of recombinant FIX Fc fusion protein (rFIXFc) activity.

View Article and Find Full Text PDF

Factor VIII (FVIII) replacement products enable comprehensive care in hemophilia A. Treatment goals in severe hemophilia A are expanding beyond low annualized bleed rates to include long-term outcomes associated with high sustained FVIII levels. Endogenous von Willebrand factor (VWF) stabilizes and protects FVIII from degradation and clearance, but it also subjects FVIII to a half-life ceiling of ∼15 to 19 hours.

View Article and Find Full Text PDF

Introduction: The one-stage clotting assay is used to measure factor IX (FIX) activity in patients' plasma samples and in FIX products for hemophilia treatment. However, the diversity of reagents and instruments has resulted in significant FIX assay variability.

Methods: The accuracy of the one-stage clotting assay to measure recombinant FIX Fc fusion protein (rFIXFc) activity was evaluated by major Japanese hemophilia treatment centers and commercial laboratories that measure factor IX activity for a majority of hemophilia B patients in Japan.

View Article and Find Full Text PDF

: The aim of this study was to compare the hemostatic efficacy of recombinant factor VIII Fc (rFVIIIFc) (Eloctate) and Advate by ex-vivo rotation thromboelastometry (ROTEM) of whole blood and to explore potential ROTEM parameters that may be more predictive of a patient's bleeding tendency than plasma FVIII activity. Thirteen clinical sites were selected to perform ROTEM on freshly collected blood samples from 44 patients in the phase 3 study for rFVIIIFc, including 16 patients undergoing sequential pharmacokinetic assessment of Advate and rFVIIIFc. Equivalent hemostatic activity was observed for rFVIIIFc and Advate in postinfusion samples, followed by improvements for rFVIIIFc in clotting time, clot formation time and alpha angle (α) for a longer duration than Advate, consistent with the pharmacokinetic improvements reported previously for rFVIIIFc.

View Article and Find Full Text PDF

Introduction: Hemophilia B is an inherited X chromosome-linked disorder characterized by impaired blood clotting owing to the absence of functional coagulation factor IX. Due to the relatively short half-life of factor IX, patients with hemophilia B require frequent factor IX infusions to maintain prophylaxis. We have developed a recombinant factor IX (rFIX) fused to the Fc region of IgG (rFIXFc) with an extended half-life in animals and humans.

View Article and Find Full Text PDF

Recombinant factor VIII Fc (rFVIIIFc) is a fusion protein consisting of a single B-domain-deleted (BDD) FVIII linked recombinantly to the Fc domain of human IgG1 to extend half-life. To determine if rFVIIIFc could be further improved by maintaining the heavy and light chains within a contiguous single chain (SC), we evaluated the activity and function of SC rFVIIIFc, an isoform that is not processed at residue R1648. SC rFVIIIFc showed equivalent activity in a chromogenic assay compared to rFVIIIFc, but approximately 40% activity by the one-stage clotting assay in the presence of von Willebrand Factor (VWF), with full activity in the absence of VWF.

View Article and Find Full Text PDF

Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.

View Article and Find Full Text PDF

Background: Prophylactic factor replacement in patients with hemophilia B improves outcomes but requires frequent injections. A recombinant factor IX Fc fusion protein (rFIXFc) with a prolonged half-life was developed to reduce the frequency of injections required.

Methods: We conducted a phase 3, nonrandomized, open-label study of the safety, efficacy, and pharmacokinetics of rFIXFc for prophylaxis, treatment of bleeding, and perioperative hemostasis in 123 previously treated male patients.

View Article and Find Full Text PDF

This phase 3 pivotal study evaluated the safety, efficacy, and pharmacokinetics of a recombinant FVIII Fc fusion protein (rFVIIIFc) for prophylaxis, treatment of acute bleeding, and perioperative hemostatic control in 165 previously treated males aged ≥12 years with severe hemophilia A. The study had 3 treatment arms: arm 1, individualized prophylaxis (25-65 IU/kg every 3-5 days, n = 118); arm 2, weekly prophylaxis (65 IU/kg, n = 24); and arm 3, episodic treatment (10-50 IU/kg, n = 23). A subgroup compared recombinant FVIII (rFVIII) and rFVIIIFc pharmacokinetics.

View Article and Find Full Text PDF

Current factor VIII (FVIII) products display a half-life (t(1/2)) of ∼ 8-12 hours, requiring frequent intravenous injections for prophylaxis and treatment of patients with hemophilia A. rFVIIIFc is a recombinant fusion protein composed of a single molecule of FVIII covalently linked to the Fc domain of human IgG(1) to extend circulating rFVIII t(1/2). This first-in-human study in previously treated subjects with severe hemophilia A investigated safety and pharmacokinetics of rFVIIIFc.

View Article and Find Full Text PDF

Recombinant FVIII formulated in PEG-ylated liposomes (rFVIII-PEG-Lip) was reported to increase the bleed-free days from 7 to 13 days (at 35 IU/kg rFVIII) in severe hemophilia A patients. To understand the underlying mechanism, we sought to recapitulate its efficacy in hemophilia A mice. Animals treated with rFVIII-PEG-Lip achieved approximately 30% higher survival relative to rFVIII after tail vein transection inflicted 24 hours after dosing.

View Article and Find Full Text PDF

In a gene therapy clinical trial for hemophilia B, adeno-associated virus 2 (AAV2) capsid-specific CD8(+) T cells were previously implicated in the elimination of vector-transduced hepatocytes, resulting in loss of human factor IX (hFIX) transgene expression. To test the hypothesis that expression of AAV2 cap DNA impurities in the AAV2-hFIX vector was the source of epitopes presented on transduced cells, transcription of cap was assessed by quantitative reverse transcription-PCR (Q-RT-PCR) following transduction of target cells with the vector used in the clinical trial. Transcriptional profiling was also performed for residual Amp(R), and adenovirus E2A and E4.

View Article and Find Full Text PDF

Hepatic adeno-associated virus (AAV)-serotype 2 mediated gene transfer results in transgene product expression that is sustained in experimental animals but not in human subjects. We hypothesize that this is caused by rejection of transduced hepatocytes by AAV capsid-specific memory CD8(+) T cells reactivated by AAV vectors. Here we show that healthy subjects carry AAV capsid-specific CD8(+) T cells and that AAV-mediated gene transfer results in their expansion.

View Article and Find Full Text PDF

Adeno-associated virus (AAV) empty capsids typically co-purify with genome containing AAV2 vectors purified by column chromatography. This study describes a method to remove empty capsids from genome containing vector particles by anion exchange chromatography. The separation is based on the slightly less anionic character of empty particles compared to vectors.

View Article and Find Full Text PDF

In a clinical study of recombinant adeno-associated virus-2 expressing human factor IX (AAV2-FIX), we detected 2 impediments to long-term gene transfer. First, preexisting anti-AAV neutralizing antibodies (NABs) prevent vector from reaching the target tissue, and second, CD8(+) T-cell responses to hepatocyte-cell surface displayed AAV-capsid-terminated FIX expression after several weeks. Because the vector is incapable of synthesizing viral proteins, a short course of immunosuppression, until AAV capsid is cleared from the transduced cells, may mitigate the host T-cell response, allowing long-term expression of FIX.

View Article and Find Full Text PDF

In a phase I study, administration of an AAV2-FIX vector into the skeletal muscle of eight hemophilia B subjects proved safe and achieved local gene transfer and FIX expression for at least 10 months after vector injection, the last time point assessed by muscle biopsy. In hemophilia B dogs we have demonstrated FIX in both muscle biopsies and circulation >4 years following AAV2-FIX injection. Because circulating FIX levels remained less than 1% of normal in human subjects from the study, the duration of AAV2-mediated transgene expression in humans is unknown.

View Article and Find Full Text PDF

The risk of germline transmission of vector sequences in humans is a major safety concern, because the enrollment of subjects of reproductive age in early-phase clinical trials of gene transfer continues to increase. In a study of adult men with hemophilia B, adeno-associated virus serotype 2 (AAV2) delivered to the liver via the hepatic artery resulted in unexpected transient vector dissemination to the semen. Here we report that intravenous AAV2 injection in rabbits proved a useful model to assess biologic parameters of vector dissemination to the semen.

View Article and Find Full Text PDF

We have previously shown that a single portal vein infusion of a recombinant adeno-associated viral vector (rAAV) expressing canine Factor IX (F.IX) resulted in long-term expression of therapeutic levels of F.IX in dogs with severe hemophilia B.

View Article and Find Full Text PDF

Long-term cures of hemophilia B have been achieved using AAV2 delivering the factor IX gene to the liver of adeno-associated virus (AAV)-naive hemophilic animals. However, the clinical success of this approach requires overcoming pre-existing AAV neutralizing antibodies prevalent in humans. To better define the inhibition of neutralizing antibodies on AAV2-mediated liver transduction, we developed an in vivo passive immunity model.

View Article and Find Full Text PDF

In this study, a modified infusion procedure and a novel infusion device designed for use in humans (Clinical Device B) were evaluated for delivery of recombinant adeno-associated virus (AAV2) to brain. The device is composed of 1.2 m of fused silica inserted through a 24.

View Article and Find Full Text PDF

Aggregation of recombinant AAV2 results in reduced yield during purification and may have deleterious effects on vector transduction efficiency, biodistribution and immunogenicity following in vivo administration. Studies to elucidate the mechanism of vector aggregation and methods to prevent its occurrence are reported. In excipient screening studies, the sugars sorbitol, sucrose, mannitol, trehalose, or glycerol at concentrations of up to 5% (w/v), or surfactants Tween 80 or Pluronic F68, did not prevent aggregation.

View Article and Find Full Text PDF

A highly sensitive assay for determination of infectious titers of recombinant adeno-associated virus (AAV) by limiting dilution analysis is described. This assay is capable of detecting single infectious events and can therefore provide an absolute rather than relative measure of infectivity. The assay utilizes a HeLa-derived AAV2 Rep/Cap-expressing cell line, D7-4, grown in 96-well plates and infected with replicate 10-fold serial dilutions of AAV2 vectors in the presence of adenovirus type 5.

View Article and Find Full Text PDF

Recombinant adeno-associated virus (AAV)-based vectors capable of expressing therapeutic gene products in vivo have shown significant promise for human gene therapy. One challenge facing the field is the development of vector formulations to achieve optimal vector safety, stability and efficacy. Formulation challenges for AAV vectors can be divided into those relating to maintaining vector activity during purification and storage, and those relating to efficient target tissue transduction in vivo.

View Article and Find Full Text PDF

We show here that UV absorbance of denatured adeno-associated virus (AAV) vector provides a simple, rapid, and direct method for quantifying vector genomes and capsid proteins in solution. We determined the molar extinction coefficients of capsid protein to be 3.72 x 10(6) M(-1) cm(-1) at 260 nm and 6.

View Article and Find Full Text PDF