In this work, photoinduced charge separation behaviors in non-long-chain-molecule-functionalized carbon nanodots (CDs) with visible intrinsic absorption (CDs-V) and TiO2 composites were investigated. Efficient photoinduced electron injection from CDs-V to TiO2 with a rate of 8.8 × 10(8) s(-1) and efficiency of 91% was achieved in the CDs-V/TiO2 composites.
View Article and Find Full Text PDFWe propose a novel method for object reconstruction of ghost imaging based on Pseudo-Inverse, where the original objects are reconstructed by computing the pseudo-inverse of the matrix constituted by the row vectors of each speckle field. We conduct reconstructions for binary images and gray-scale images. With equal number of measurements, our method presents a satisfying performance on enhancing Peak Signal to Noise Ratio (PSNR) and reducing computing time.
View Article and Find Full Text PDFNovel luminescent "nano-bombs" based on a self-assembled system of carbon-nanodots, termed supra-CDs, are developed. The luminescence of these luminescent "nano-bombs" depends strongly on water contact; they show weak emission in toluene and decompose in contact with water, resulting in strong photoluminescence. Paper coated with these "nano-bombs" is successfully applied for water-jet printing of luminescence patterns and the mapping of human sweat-pore patterns.
View Article and Find Full Text PDFA construction strategy for ratiometric fluorescent nanosensors based on water soluble C-dots was developed, which could sense temperature (10-82 °C), pH values (lower than 6.0 or higher than 8.6) and Fe(3+) ions (>0.
View Article and Find Full Text PDFIn this article we describe commissioning and implementation procedures for the Dose Verification System (DVS) with permanently implanted in vivo wireless, telemetric radiation dosimeters for absolute dose measurements. The dosimeter uses a semiconductor device called a metal-oxide semiconductor field-effect transistor (MOSFET) to measure radiation dose. A MOSFET is a transistor that is generally used for amplifying or switching electronic signals.
View Article and Find Full Text PDFPurpose: To explore the incidence and risk factors for treatment-related acute esophagitis associated with involved-field radiation therapy (RT) delivered concurrently with chemotherapy for patients with locoregionally advanced non-small cell lung cancer.
Materials And Methods: Forty-nine consecutive patients diagnosed with locoregionally advanced non-small cell lung cancer were treated using involved-field RT. Radiotherapy target volumes included the primary lung tumor and involved mediastinal lymphadenopathy as defined on imaging studies including computed tomography of the chest and fluorodeoxyglucose-positron emission tomography/computed tomography.
Purpose: Internal target volume (ITV) is frequently determined by contouring of gross tumor volumes (GTV) on 10 phases of a 4-dimensional computed tomography (4DCT) study set for lung cancer radiotherapy. This study aimed to investigate the possibility of generating ITV by using selective phases of a 4DCT scan.
Methods And Materials: The 4DCT scans of 20 patients with lung cancer were included in this study.
Int J Radiat Oncol Biol Phys
July 2012
Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT).
View Article and Find Full Text PDFLaser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were made on the Wistar rat's dorsal skin.
View Article and Find Full Text PDFThe standard treatment technique used for whole-breast irradiation can result in undesirable dose distributions in the treatment site, leading to skin reaction/fibrosis and pulmonary and cardiac toxicities. Hence, the technique has evolved from conventional wedged technique (CWT) to segment intensity-modulated radiation therapy (SIMRT) and beamlet IMRT (IMRT). However, these newer techniques feature more highly modulated dose distributions that may be affected by respiration.
View Article and Find Full Text PDFPurpose: To study the impact of seed localization, as performed by different observers using linked (125)I seeds, on postimplant dosimetry in prostate brachytherapy and, to compare transrectal ultrasound (TRUS)-based with CT-based approach for the dosimetric outcomes.
Methods And Materials: Nineteen permanent prostate implants were conducted using linked (125)I seeds. Postimplant TRUS and CT images were acquired and prostate glands were, after implantation, delineated on all images by a single oncologist, who had performed all 19 seeding procedures.