Nihon Hoshasen Gijutsu Gakkai Zasshi
November 2021
Dynamic chest radiography (DCR) is a flat-panel detector (FPD) -based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view of FPDs permits real-time observation of motion/kinetic findings on the entire lungs, right and left diaphragm, ribs, and chest wall; heart wall motions; respiratory changes in lung density; and diameter of the intrathoracic trachea. Since the dynamic FPDs had been developed in the early 2000s, we focused on the potential of dynamic FPDs for functional X-ray imaging and have launched a research project for the development of an imaging protocol and digital image-processing techniques for the DCR.
View Article and Find Full Text PDFInt J Chron Obstruct Pulmon Dis
July 2021
Objective: The aim of this study was to identify the relationships between parameters obtained from dynamic-ventilatory digital radiography (DR) and ventilatory disorders.
Methods: This study comprised 273 participants with respiratory diseases who underwent spirometry and functional residual capacity measurements (104 with normal findings on spirometry as controls, 139 with an obstructive lung disorder, 30 with a restrictive lung disorder) were assessed by dynamic-ventilatory DR. Sequential chest radiography images of the patient's slow and maximum breathing were captured at 15 frames per second by a dynamic flat-panel imaging system.
One-hundred-and-twenty-eight-section dual X-ray source computed tomography (CT) systems have been introduced into clinical practice and have been shown to increase temporal resolution. Higher temporal resolution allows low-dose spiral mode at a high pitch factor during CT coronary angiography. We evaluated radiation dose and physical image qualities in CT coronary angiography by applying high-pitch spiral, step-and-shoot, and low-pitch spiral modes to determine the optimal acquisition mode for clinical situations.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2012
We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.
View Article and Find Full Text PDFRationale And Objectives: Chest computed tomographic (CT) scans are the most effective examinations for detecting lung cancer at an early stage. In chest CT examinations, it is important to consider the reduction of radiation dose, particularly to the mammary gland. The objective of this study was to assess breast doses and effective doses on chest CT examinations between three-dimensional and z-axis automatic tube current modulation (ATCM) techniques.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
February 2006
To avoid radiation injury from interventional radiology (IVR), quality assurance (QA) of IVR equipment based on dosimetry is important. In this study, we investigated the usefulness of measuring patient skin dose with a passive integrating dosimeter and water phantom. The optically stimulated luminescence dosimeter (OSLD) was chosen from among various passive integrating dosimeters.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2005
Radiation dose limits in the controlled area of an X-ray room have been prescribed at 1.3 mSv/3 months by the Enforcement Regulations of the Medical Service Law. Leakage effective dose must be measured once within a period that does not exceed six months.
View Article and Find Full Text PDFA study was performed to evaluate operator dose during diagnostic and interventional radiology procedures (IVR) and to establish methods of operator dose reduction with a radiation protective device. Operator dose was measured by glass dosimeters worn on the neck and on the abdomen outside the lead apron. In addition, the dose of the primary beam at the collimator surface was measured, which made it possible to define the correlation between the entrance air kerma, measured with Skin Dose Monitor, and operator dose exposed during the monitored procedure.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2004
A study was performed to evaluate the total entrance skin dose (ESD) of patients during diagnostic and interventional radiology procedures (IVR) and to estimate ESD with body mass index (BMI) and fluoroscopy time. The study included 26 cases of transcatheter arterial embolization therapy (TAE) for hepatocellular carcinoma (HCC) and 19 cases of diagnostic digital subtraction angiography (DSA) for HCC. The ESD of patients was evaluated with a zinc-cadmium sensor linked to a digital counter (SDM: skin dose monitor).
View Article and Find Full Text PDF