Publications by authors named "Junichiro Wada"

Article Synopsis
  • - The study compared the accuracy of impressions taken of hypermobile teeth in partially edentulous dental arches using digital and conventional methods, assessing a mandibular model with three target teeth.
  • - Results showed that digital impressions significantly outperformed hydrocolloid impressions for two of the three teeth tested, while the accuracy of digital and silicone impressions was similar.
  • - The research concluded that using an intraoral scanner (digital method) is preferable for minimizing hypermobile tooth deviations compared to hydrocolloid impressions, with the accuracy varying based on the specific tooth's location.
View Article and Find Full Text PDF

The purpose of this study was to investigate the fracture behavior of endodontically treated (ET) deciduous molar when directly restored with different restorative materials in Class II (MO) cavities in comparison with permanent teeth. MO cavities were prepared with 2.4-2.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of chemical, mechanical, and combination surface treatments on the shear bond strength (SBS) of autopolymerizing repair resin to conventional heat-cured, computer aided design (CAD)-computer aided manufacturing (CAM) milled, and three-dimensionally (3D) printed denture base materials.

Methods: Specimens were fabricated and divided according to the surface treatment as follows: no surface treatment (control group), monomer treatment (monomer group), resin remover treatment (resin remover group), roughening with 180 FEPA grit abrasive paper followed by monomer treatment (180-grit plus monomer group), and air particle abrasion (air abrasion group). Autopolymerizing resin cylinders were attached before accelerated aging of the specimens in water at 100 °C for 16 h.

View Article and Find Full Text PDF

Purpose: To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints.

Methods: Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water.

View Article and Find Full Text PDF

Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.

View Article and Find Full Text PDF

This study aimed to evaluate the effect of splinting material type and material location on the force resistance of splinted periodontally compromised teeth with hypermobility. Extracted teeth including the target tooth (maxillary second premolar) and its adjacent teeth were placed into the alveolar sockets of a dental arch model via artificial periodontal ligaments made of elastic impression material. Three different experimental models with varied target tooth mobility including Periotest® values (PTVs) of 20, 30, and 40 were fabricated (named models #20, #30, and #40, respectively).

View Article and Find Full Text PDF

Although additive manufacturing has been widely applied for occlusal splint (OS) fabrication, it is still unclear whether 3D printing system and post-curing atmosphere would play a role in the wear resistance of additive-manufactured OS. Therefore, the aim of this study was to evaluate the effect of 3D printing system (liquid crystal display (LCD) and digital light processing (DLP)) and post-curing atmosphere (air and nitrogen gas (N)) on the wear resistance of hard and soft OS materials for additive-manufactured OSs (KeySplint® Hard and Soft). The evaluated properties were microwear (by two-body wear test) and nano-wear resistances (by nanoindentation wear test) as well as flexural strength and flexural modulus (by three-point bending test), surface microhardness (by Vickers hardness test), and nanoscale elastic modulus (reduced elastic modulus) and nano surface hardness (by nanoindentation test).

View Article and Find Full Text PDF

Purpose: To verify the effect of abutment tooth location on the accuracy of digital impressions obtained using an intraoral scanner (IOS) for removable partial dentures (RPDs).

Methods: The target abutment teeth included the left first premolar (#34), second molar (#37), and right second premolar (#45) in a mandibular Kennedy class II model and the left and right second molars (#37, #47) in a class III model. Only #37 was isolated from the remaining teeth by the mucosal area in both models.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of surface polishing as well as the post-curing atmospheres (air and nitrogen gas) on the physical properties of an occlusal splint material for additive manufacturing. Flexural strength, flexural modulus, Vickers hardness number (VHN), degree of carbon double bond conversion (DC), water sorption (W), and water solubility (W) were evaluated. Surface polishing significantly affected the evaluated properties.

View Article and Find Full Text PDF

Background: Dental enamel, the hardest outermost layer of a human tooth, is subjected to occlusal forces throughout life during different oral function as talking, mastication etc. Due to this continuous stress, wear causes the loss of this protective shell. This study aimed to detect microscopic differences in enamel's wear behavior among different age groups of adolescents and adults.

View Article and Find Full Text PDF

The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D).

View Article and Find Full Text PDF

Purpose: Coronavirus disease 2019 has forced the use of remote education worldwide. In 2020, the authors conducted a fully digitized, remote flipped (RF) classroom focusing on removable partial dentures. This study aimed to evaluate the learning outcomes of the RF classroom and compare these with those of the on-site classroom.

View Article and Find Full Text PDF

Purpose: To determine postoperative periodontal and radiographic factors that predict the survival rates of abutments of removable partial dentures (RPDs).

Methods: Patients who wore RPDs for > 10 years and received supportive periodontal therapy were included. Periodontal examinations and radiographic assessments were conducted on 83 abutment teeth in 35 patients at baseline, and five years after RPD insertion.

View Article and Find Full Text PDF

Despite the fact that three-dimensional (3D) printing is frequently used in the manufacturing of occlusal splints, the effects of the 3D printer type and post-curing methods are still unclear. The aim of this study was to investigate the effect of the printer type (digital light processing: DLP; and liquid crystal display: LCD) as well as the post-curing method with two different atmospheric conditions (air and nitrogen gas (N)) on the mechanical and surface properties of 3D-printed soft-type occlusal splint material. The evaluated properties were flexural strength, flexural modulus, Vickers hardness (VHN), fracture toughness, degree of double bond conversion (DC%), water sorption, water solubility, and 3D microlayer structure.

View Article and Find Full Text PDF

Although three-dimensional (3D) printing is clinically convenient to fabricate occlusal splints, it is still unclear how the post-curing method and the printer type can affect 3D-printed splints. This study aimed to evaluate the effect of stroboscopic post-curing at a nitrogen gas (N) atmosphere versus post-curing in an air atmosphere, as well as the printer type (liquid crystal display (LCD) and digital light processing (DLP)) on the mechanical properties of a 3D-printed hard-type occlusal splint material. Flexural strength, flexural modulus, Vickers hardness number (VHN), fracture toughness, degree of double bond conversion (DC), 3D microlayer structure, water sorption, and water solubility were evaluated.

View Article and Find Full Text PDF

Purpose We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis.Methods Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.

View Article and Find Full Text PDF

This study aimed to evaluate the effect of retention hole designs in artificial teeth on failure resistance of the connection with a thermoplastic denture base resin. Artificial teeth with the following retention hole designs were attached to polyester and polyamide resins: no hole, vertical hole, horizontal hole, and vertical and horizontal holes. An artificial tooth with no hole attached to polymethyl methacrylate was prepared as the control.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the inhibitory effect of night denture (ND) placement on abutment tooth mobility in removable partial denture (RPD) wearers with sleep bruxism (SB).

Methods: The participants were selected from RPD wearers diagnosed with SB using BiteStrip® and randomly allocated to one of the following groups: with ND placement or without ND placement (intervention or control group, respectively). The mobility of the RPD abutment tooth was measured using Periotest® at baseline (T0) and at 1 (T1), 3 (T3), and 6 months (T6).

View Article and Find Full Text PDF

Purpose: This retrospective study evaluated the periodontal tissues of the abutment teeth of removable partial dentures (RPDs) with rigid retainers and major connectors in patients with and without type 2 diabetes mellitus (T2D).

Methods: A total of 313 patients who had been treated with RPDs, including rigid retainers and major connectors, were divided into two groups: T2D and non-T2D. The periodontal parameters and radiographic bone heights of the abutment teeth were evaluated at baseline and at a 5-year examination during supportive periodontal therapy (SPT).

View Article and Find Full Text PDF

Purpose: This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base.

Study Selection: We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses.

View Article and Find Full Text PDF

Purpose: This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.

Study Selection: We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis.

View Article and Find Full Text PDF

Background: Surface replication is a nondestructive evaluation technique applied in examining surface wear by recording surface irregularities, especially in conditions when surfaces of interest cannot be further manipulated to fit directly under a microscope to be examined. Enamel is the outermost protective layer of the human teeth and is constantly stressed by mastication forces which results in enamel wear.

Objective: To date, a procedure combining the clinical and microscopic examination of enamel surfaces is absent, which hinders the early diagnosis and comprehension of the wear process.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the relationship between the retromolar gland and pad, and the relationship between the LN and retromolar gland/pad to establish a new landmark for avoiding LN injury.

Methods: Sixty-two lingual nerves from fresh-frozen cadavers were used for this study. The age of the specimens at the time of death ranged from 57 to 98 with a mean of 76.

View Article and Find Full Text PDF

Background/objectives: Speech impairment during the initial phase of removable partial denture (RPD) treatment can prevent patient adaptation to RPDs. This quasi-experimental study aimed to investigate the influence of the covering area of major connectors located in the mandibular anterior region on the accuracy of speech production.

Methods: Fifteen adults (12 men and 3 women aged 26-40 years) with healthy dentition were recruited.

View Article and Find Full Text PDF