Publications by authors named "Jungkuk Kim"

Background: Acupuncture treatments that regulate the heart are used to treat various clinical disorders and conditions. Although many studies have been conducted to measure quantitatively the effects of acupuncture, thus far, models that describe these effects have not been established. The purpose of this study was to derive a transfer function model of acupuncture stimulation within the electrocardiograms based on the periods before, during, and after acupuncture.

View Article and Find Full Text PDF

A new electrocardiogram (ECG) reconstruction method based on a state-space model is presented. This method was applied to reconstruct precordial leads from limb leads (lead I, II, III) for its validity verification. The system matrices of the state-space model were estimated at the model estimation stage by considering the limb lead signals as the input of the system and precordial lead signals as the output.

View Article and Find Full Text PDF

Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation.

Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS).

View Article and Find Full Text PDF

This paper introduces a real-time data compression and transmission algorithm between e-health terminals for a periodic ECGsignal. The proposed algorithm consists of five compression procedures and four reconstruction procedures. In order to evaluate the performance of the proposed algorithm, the algorithm was applied to all 48 recordings of MIT-BIH arrhythmia database, and the compress ratio (CR), percent root mean square difference (PRD), percent root mean square difference normalized (PRDN), rms, SNR, and quality score (QS) values were obtained.

View Article and Find Full Text PDF

In this article, we developed an m-health monitoring system using a Nintendo DS game console to demonstrate its utility. The proposed system consists of a biosignal acquisition device, wireless sensor network, base-station for signal reception from the sensor network and signal conversion according to Internet protocol, personal computer display program, and the Nintendo DS game console. The system collects three-channel electrocardiogram (ECG) signals for cardiac abnormality detection and three-axis accelerometer signals for fall detection of a person.

View Article and Find Full Text PDF

In this paper a simple signal segmentation algorithm is introduced. The algorithm determines the epochs of signal components of interest based on signal characteristic such as amplitude, slope, deflection width, or distance between neighboring deflections. The epochs are segmented indirectly by means of a slope trace wave that traces a signal with its average slope and predetermined delay.

View Article and Find Full Text PDF

In this paper, we used the hand held type a Nintendo DS Game Machine for consisting of a u-Health Monitoring system. This system is consists of four parts. Biosignal acquire device is the first.

View Article and Find Full Text PDF

This paper introduces a new approach to process biomedical signals by surgically removing wave deflections in time domain. The method first determines the epochs of high frequency deflections, cuts out them from the signal, and then connects the two disconnected points. To determine the epoch of a deflection to be removed, four slope trace waves are used to isolate the deflection based on signal characteristics of amplitude, slope, duration, and distance from neighboring deflections.

View Article and Find Full Text PDF