Publications by authors named "Jung-Han Choi"

In this study, we propose an optimized AlGaN/GaN high-electron-mobility transistor (HEMT) with a considerably improved breakdown voltage. First, we matched the simulated data obtained from a basic T-gate HEMT with the measured data obtained from the fabricated device to ensure the reliability of the simulation. Thereafter, to improve the breakdown voltage, we suggested applying a gate-head extended structure.

View Article and Find Full Text PDF

This study investigates the operational characteristics of AlGaN/GaN high-electron-mobility transistors (HEMTs) by applying a slant-gate structure and drain-side extended field-plate (FP) for improved breakdown voltage. Prior to the analysis of slant-gate-based HEMT, simulation parameters were extracted from the measured data of fabricated basic T-gate HEMTs to secure the reliability of the results. We suggest three different types of slant-gate structures that connect the basic T-gate electrode boundary to the 1st and 2nd SiN passivation layers obliquely.

View Article and Find Full Text PDF

The aim of the present study was to investigate the anti-inflammatory effects of glycine thymosin β4 (Gly-Tβ4) eye drops, and to compare the efficacy of topical Gly-Tβ4 with Cyclosporine A (CsA) in a mouse model of experimental dry eye (EDE). Eye drops consisting of balanced salt solution (BSS), 0.1% Gly-Tβ4 or 0.

View Article and Find Full Text PDF

Aim: To investigate the abnormalities in the meibomian gland in patients with dry eye disease (DED) associated with chronic ocular graft-versus-host disease (coGVHD) in comparison with Sjögren's syndrome (SS), a major form of aqueous deficient DED and meibomian gland dysfunction (MGD), a common cause of evaporative DED.

Methods: A total 135 eyes of 135 subjects included in this study: patients with DED associated with coGVHD (=30), patients with SS (=35), patients with MGD (=35), and normal controls (=35). All participants completed the Ocular Surface Disease Index (OSDI) questionnaire, ocular surface examination [Schirmer test, tear film breakup time (TFBUT), and ocular surface staining], and meibomian gland assessment [meiboscore (gland dropout detected on meibography using infrared camera of the Keratograph 5M), meibum expressibility score (MES), meibum quality score (MQS), lid margin abnormality].

View Article and Find Full Text PDF

Purpose: To investigate the efficacy and safety of a new cyclosporine A (CsA) delivery system using contact lenses (CLs) for the treatment of experimental dry eye (EDE).

Methods: CsA-laden porous carriers and CsA-eluting CLs were fabricated using the supercritical fluid technique. The release of CsA from carriers and CLs was investigated using high-performance liquid chromatography.

View Article and Find Full Text PDF

Purpose: To investigate the influences of smartphone use on ocular symptoms, status of the tear film, and oxidative stress indices in the tears and at the ocular surface.

Methods: Eighty healthy volunteers were enrolled in the study. Subjective symptoms and asthenopia were evaluated using the ocular surface disease index (OSDI), visual analogue scale (VAS), and computer vision syndrome (CVS) score before and after smartphone or computer display (control) use.

View Article and Find Full Text PDF

Purpose: To investigate the therapeutic effects of mineral oil (MO) and hyaluronic acid (HA) mixture eye drops on the tear film and ocular surface in a mouse model of experimental dry eye (EDE).

Methods: Eye drops consisting of 0.1% HA alone or mixed with 0.

View Article and Find Full Text PDF

Purpose: To investigate the efficacy of the topical application of omega-3 essential fatty acids (EFAs) and hyaluronic acid (HA) mixtures in a mouse model of experimental dry eye (EDE).

Methods: Eye drops consisting of 0.1% HA, 0.

View Article and Find Full Text PDF

Objective: To investigate the efficacy of WINROP (https://winrop.com), an algorithm based on serial measurements of neonatal body weight to predict proliferative retinopathy of prematurity (ROP), in a Korean population of preterm infants.

Methods: The records of preterm infants with gestational age less than 32 weeks who were admitted to the neonatal intensive care unit at Chonnam National University Hospital, Gwangju, South Korea, from October 2006 to November 2010 were reviewed.

View Article and Find Full Text PDF

We demonstrate the first integrated transmitter for serial 100 Gb/s NRZ-OOK modulation in datacom and telecom applications. The transmitter relies on the use of an electro-optic polymer modulator and the hybrid integration of an InP laser diode and InP-DHBT electronics with the polymer board. Evaluation is made at 80 and 100 Gb/s through eye-diagrams and BER measurements using a receiver module that integrates a pin-photodiode and an electrical 1:2 demultiplexer.

View Article and Find Full Text PDF

We investigated the radio-frequency transmission properties of reduced graphene oxide (GO) sheets including contact effects with the metal electrodes. GO sheets were prepared by dielectrophoresis and their structural characteristics were analyzed by x-ray photoelectron spectroscopy and Raman spectroscopy. The contact resistance was much higher than the intrinsic resistance over the entire frequency range, thus the contact resistance was considered as a dominant component of impedance in the radio-frequency regime.

View Article and Find Full Text PDF

By using the film mode matching method, a novel design for asymmetrical multi-section 1.55/1.31 μm wavelength splitter based on multimode interference has been proposed and simulated, which can be effectively applied to wavelength multiplexer, self-biased photodiode, and other optical devices.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the effect of different screw-tightening sequences, torques, and methods on the strains generated on an internal-connection implant (Astra Tech) superstructure with good fit.

Materials And Methods: An edentulous mandibular master model and a metal framework directly connected to four parallel implants with a passive fit to each other were fabricated. Six stone casts were made from a dental stone master model by a splinted impression technique to represent a well-fitting situation with the metal framework.

View Article and Find Full Text PDF

Purpose: This study compared the removal torque values (RTVs) of different abutments (straight, angled, and gold premachined UCLA-type) in external- and internal-hex implants after dynamic cyclic loading with the clinical situation of the anterior maxilla simulated.

Materials And Methods: An ideal cast of a maxilla with a missing right central incisor was fabricated in dental stone, and an implant analog was embedded in this model at a 15-degree angle labial to the long axis of the left central incisor. Thirty external-hex and 30 internal-hex implants were used.

View Article and Find Full Text PDF

Purpose: This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cementon crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated.

Material And Methods: Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks.

View Article and Find Full Text PDF

Purpose: This study evaluated the effect of different screw-tightening sequences, forces, and methods on the stresses generated on a well-fitting internal-connection implant (Astra Tech) superstructure.

Materials And Methods: A metal framework directly connected to four parallel implants was fabricated on a fully edentulous mandibular resin model. Six stone casts with four implant replicas were made from a pickup impression of the superstructure to represent a "well-fitting" situation.

View Article and Find Full Text PDF

A remote compact sensor system for the detection of human vital signs (heartbeat and respiration rate) is presented. The frequency band of 24 GHz is employed for remote sensing. For the compact size, the developed sensor uses a circularly polarized electromagnetic wave with a single antenna.

View Article and Find Full Text PDF

Purpose: This study evaluated the accuracy of 2 implant-level impression techniques (direct nonsplinted and splinted) for the fabrication of multi-unit internal-connection implant restorations in 2 simulated clinical settings (parallel and divergent) using a laboratory model.

Materials And Methods: A dental stone master model was fabricated with 2 pairs of implant replicas. One pair simulated a parallel clinical condition and the other an 8-degree-divergent condition.

View Article and Find Full Text PDF