The quality of the visual information transmitted from a scene is crucial for effective medical supervision in prehospital settings. This study investigated the influence of wearable camera mount locations on visibility during simulated out-of-hospital cardiopulmonary resuscitation. A prospective, observational, non-randomized simulation study was conducted to replicate a cardiac arrest scenario adhering to an advanced life support (ALS) protocol.
View Article and Find Full Text PDFBioinspir Biomim
October 2024
Soft peristaltic pumps, which use soft ring actuators instead of mechanical pistons or rollers, offer advantages in transporting liquids with non-uniform solids, such as slurry, food, and sewage. Recent advances in 3D printing with flexible thermoplastic polyurethane (TPU) present the potential for single-step fabrication of these pumps, distinguished from handcrafted, multistep traditional silicone casting methods. However, because of the relatively high hardness of TPU, TPU-based soft peristaltic pumps contract insufficiently and thus cannot perform as well as silicone-based ones.
View Article and Find Full Text PDFIEEE J Transl Eng Health Med
August 2024
Objective: This study introduces a novel system that can simulate diverse mechanical properties of the human chest to enhance the experience of CPR training by reflecting realistic chest conditions of patients.
Methods: The proposed system consists of Variable stiffness mechanisms (VSMs) and Variable damper (VD) utilizing stretching silicone bands and dashpot dampers with controllable valves to modulate stiffness and damping, respectively. Cyclic loading was applied with a robot manipulator to the system.
Aim Of The Study: We evaluated whether an artificial intelligence (AI)-driven robot cardiopulmonary resuscitation (CPR) could improve hemodynamic parameters and clinical outcomes.
Methods: We developed an AI-driven CPR robot which utilizes an integrated feedback system with an AI model predicting carotid blood flow (CBF). Twelve pigs were assigned to the AI robot group (n = 6) and the LUCAS 3 group (n = 6).
Diagnostics (Basel)
May 2024
Endotracheal suctioning is an essential but labor-intensive procedure, with the risk of serious complications. A brand new automatic closed-suction device was developed to alleviate the workload of healthcare providers and minimize those complications. We evaluated the clinical efficacy and safety of the automatic suction system in mechanically ventilated patients with pneumonia.
View Article and Find Full Text PDFThis study proposes the use of vocal resonators to enhance cardiac auscultation signals and evaluates their performance for voice-noise suppression. Data were collected using two electronic stethoscopes while each study subject was talking. One collected auscultation signal from the chest while the other collected voice signals from one of the three voice resonators (cheek, back of the neck, and shoulder).
View Article and Find Full Text PDFBackground: Recently, we developed a chest compression device that can move the chest compression position without interruption during CPR and be remotely controlled to minimize rescuer exposure to infectious diseases. The purpose of this study was to compare its performance with conventional mechanical CPR device in a mannequin and a swine model of cardiac arrest.
Materials And Methods: A prototype of a remote-controlled automatic chest compression device (ROSCER) that can change the chest compression position without interruption during CPR was developed, and its performance was compared with LUCAS 3 in a mannequin and a swine model of cardiac arrest.
Recognizing anatomical sections during colonoscopy is crucial for diagnosing colonic diseases and generating accurate reports. While recent studies have endeavored to identify anatomical regions of the colon using deep learning, the deformable anatomical characteristics of the colon pose challenges for establishing a reliable localization system. This study presents a system utilizing 100 colonoscopy videos, combining density clustering and deep learning.
View Article and Find Full Text PDFBackground: Elastomeric pumps have a curved infusion rate profile over infusion time. Chemically driven pumps can overcome such limitations of elastomeric pumps and infuse constantly. However, studies on the pharmacokinetic benefit of chemically-driven pumps are insufficient.
View Article and Find Full Text PDFObjectives: This study evaluated suture tie-down forces and cyclic contractile forces (CCFs) after undersized tricuspid annuloplasty using a hybrid band.
Methods: Downsized tricuspid annuloplasty was planned in adult male sheep using 8 force transducers attached from the septal to the anterior annular areas of the ring (segments 1 and 2, flexible septal; segments 3 and 4, semi-rigid posterior; segments 5 and 6, semi-rigid anterior; segments 7 and 8, flexible anterior). CCFs were analysed at 3 different levels of peak right ventricular pressure (RVP): 30, 50 and 70 mmHg.
Background: There is a need for development of reliable and accessible clinical biomarker for detecting cognitive dysfunction in PD. This study aimed to investigate whether involuntary head rotation during the saccade test could serve as a potential biomarker for screening cognitive dysfunction in PD.
Methods: A total of 27 PD patients and nine age- and sex-matched healthy controls were prospectively enrolled in this study.
Telemedicine data are measured directly by untrained patients, which may cause problems in data reliability. Many deep learning-based studies have been conducted to improve the quality of measurement data. However, they could not provide an accurate basis for judgment.
View Article and Find Full Text PDFLittle is known about the myopic characteristics of lamina cribrosa (LC) curvature. As such, we investigated nasal and temporal LC curvatures in myopia. In this retrospective, cross-sectional study, 144 myopic eyes (refraction < - 2D) and 88 non-myopic eyes (refraction > - 0.
View Article and Find Full Text PDFThermal damage and inflammatory responses of the sphincter and neurovascular bundles (NVBs) are responsible for post-prostatectomy incontinence and erectile dysfunction. Intraoperative hypothermia in the pelvic cavity may reduce the occurrence of these complications. We evaluated the feasibility of a novel rectal cooling system using an animal model.
View Article and Find Full Text PDFBackground: Autologous fat grafting is one of the most common procedures used in plastic surgery to correct soft tissue deficiency or depression deformity. However, its clinical outcomes are often suboptimal, and lack of metabolic and architectural support at recipient sites affect fat survival leading to complications such as cyst formation, calcification. Extracellular matrix-based scaffolds, such as allograft adipose matrix (AAM) and poly(lactic-co-glycolic) acid (PLGA), have shown exceptional clinical promise as regenerative scaffolds.
View Article and Find Full Text PDFBackground/aim: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is known to show uneven distribution and penetration of agents based on the nozzle position. Thus, this study aimed to investigate the ideal nozzle position for maximizing drug delivery during PIPAC.
Materials And Methods: We created 2 cm-, 4 cm- and 8 cm-ex vivo models according to the distance from the bottom to the nozzle using 21×15×16 cm-sized sealable plastic boxes.
Background: Diesel exhaust particles (DEPs) are the main component of traffic-related air pollution and have been implicated in the pathogenesis and exacerbation of asthma. However, the mechanism by which DEP exposure aggravates asthma symptoms remains unclear.
Objective: This study aimed to identify a key cellular player of air pollutant-induced asthma exacerbation and development.
Aim: To establish an experimental system for comparing different methods of intraperitoneal chemotherapy in a rat model.
Materials And Methods: We used six-week-old Sprague-Dawley rats, and created an early postoperative intraperitoneal chemotherapy (EPIC) system using 18-gauge syringes and evacuators, and a hyperthermic intraperitoneal chemotherapy (HIPEC) system using two peristaltic pumps which controlled the flow rate and temperature. Pressurized intraperitoneal aerosol chemotherapy (PIPAC) was achieved using a nozzle for dispersing aerosols at a flow rate up to 41.
IEEE J Transl Eng Health Med
December 2021
A simulator for retrobulbar anesthesia administration mimicking the orbital anatomy and providing tactile sensation is proposed. The production process involves 3D modeling of anatomical structures on the basis of computerized tomography (CT) images, printing the models using a 3D printer, and casting the silicone. Twenty ophthalmologists administered retrobulbar anesthesia using the simulator with four different ocular axial lengths (including extreme myopes); the position of the needle tip was evaluated.
View Article and Find Full Text PDFObjective: We developed and validated a realistic simulation model for ultrasound-guided central venous catheter insertion in children that is easy to build and inexpensive and can automatically reproduce arterial and venous blood flow.
Methods: The simulation model was constructed with a chicken breast, two DWP-385 water pumps, two types of tubes and a controller. An elastic rubber tourniquet and a silicone tube were connected to each water pump, which generated different continuous flows mimicking those of the pediatric internal carotid artery and internal jugular vein, respectively.
This study aims to evaluate the drug distribution, tissue concentrations, penetration depth, pharmacokinetic properties, and toxicities after rotational intraperitoneal pressurized aerosol chemotherapy (RIPAC) in pigs. Because relevant medical devices have not been introduced, we developed our prototype of pressurized intraperitoneal aerosol chemotherapy (PIPAC) and RIPAC by adding a conical pendulum motion device for rotating the nozzle. RIPAC and PIPAC were conducted using 150 ml of 1% methylene blue to evaluate the drug distribution and 3.
View Article and Find Full Text PDF