In this study, we propose a single camera-based dual-channel near-infrared (NIR) fluorescence imaging system that produces color and dual-channel NIR fluorescence images in real time. To simultaneously acquire color and dual-channel NIR fluorescence images of two fluorescent agents, three cameras and additional optical parts are generally used. As a result, the volume of the image acquisition unit increases, interfering with movements during surgical procedures and increasing production costs.
View Article and Find Full Text PDFWe developed a single-camera-based near-infrared (NIR) fluorescence imaging device using indocyanine green (ICG) NIR fluorescence contrast agents for image-induced surgery. In general, a fluorescent imaging system that simultaneously provides color and NIR images uses two cameras, which is disadvantageous because it increases the imaging head of the system. Recently, a single-camera-based NIR optical imaging device with quantum efficiency partially extended to the NIR region was developed to overcome this drawback.
View Article and Find Full Text PDFHerein we propose a method to mitigate a position mismatch problem for a spectral-domain polarization-sensitive optical coherence tomography (SD-PS-OCT) system that uses a single line-scan detection scheme. A single detector-based PS-OCT detects two orthogonal polarization components as two adjacent A-scan signals in turns. Thus, two adjacent A-scan signals are not scattered at a fixed point in time (position mismatch problem), resulting in uncorrelated signals between them.
View Article and Find Full Text PDFWe have developed a surgical microscope-integrated optical coherence tomography (MI-OCT) system based on an active feedback method to obtain uniform optimal OCT image contrast along the depth of focus (DOF) of a surgical microscope. Conventional MI-OCT systems use a shorter DOF objective lens than those of surgical microscopes for OCT imaging. The existing MI-OCT system was developed to overcome sensitivity roll-off by using an electrically tunable lens (ETL).
View Article and Find Full Text PDFOptical coherence tomography (OCT) is a noninvasive imaging modality that can provide high-resolution, cross-sectional images of tissues. Especially in retinal imaging, OCT has become one of the most valuable imaging tools for diagnosing eye diseases. Considering the scattering and absorption properties of the eye, the 1000-nm OCT system is preferred for retinal imaging.
View Article and Find Full Text PDFThe hippocampus is associated with memory and navigation, and the rodent hippocampus provides a useful model system for studying neurophysiology such as neural plasticity. Vascular changes at this site are closely related to brain diseases, such as Alzheimer's disease, dementia, and epilepsy. Vascular imaging around the hippocampus in mice may help to further elucidate the mechanisms underlying these diseases.
View Article and Find Full Text PDFWe propose a robust method that can quantitatively discriminate genuine pearls from imitation ones by introducing the concept of entropy in the polarization-sensitive optical coherence tomography (PS-OCT). Qualitatively, by examining the birefringence properties of the nacre region of pearls with PS-OCT, the genuine pearls can be easily discriminated. To quantify the amount of birefringence formation, however, the concept of phase retardation entropy is introduced, which is expected to have a higher value when a PS-OCT tomogram has more diverse phase retardation values in its histogram.
View Article and Find Full Text PDFTendons are tough, flexible, and ubiquitous tissues that connect muscle to bone. Tendon injuries are a common musculoskeletal injury, which affect 7% of all patients and are involved in up to 50% of sports-related injuries in the United States. Various imaging modalities are used to evaluate tendons, and both magnetic resonance imaging and sonography are used clinically to evaluate tendons with non-invasive and non-ionizing radiation.
View Article and Find Full Text PDFWe have employed Fourier-domain optical coherence tomography (FD-OCT) to achieve corneal nerve imaging, which could be useful in surgical planning and refractive surgery. Because the three-dimensional (3-D) images of the corneal nerves were acquired in vivo, unintentional movement of the subject during the measurement led to imaging artifacts. These artifacts were compensated for with a series of signal processing techniques, namely realigning A-scan images to flatten the boundary and cross-correlating adjacent B-scan images.
View Article and Find Full Text PDFPurpose: To elucidate the anatomic details of gland dropout detected on two-dimensional infrared (IR) meibography in cases of dry eye associated with meibomian gland dysfunction (MGD) by using three-dimensional optical coherence tomography (OCT) meibography.
Methods: In this cross-sectional, observational case series, we enrolled gland dropout detected on IR meibography; the condition was then examined using a real-time swept-source OCT system. Accordingly, a series of 500 raster B-scan OCT images, with the gland dropout site (observed on IR imaging) at the center, were obtained and rendered as three-dimensional volume images.
We propose an all-fiber-based dual-modal imaging system that combines noncontact photoacoustic tomography (PAT) and optical coherence tomography (OCT). The PAT remotely measures photoacoustic (PA) signals with a 1550-nm laser on the surface of a sample by utilizing a fiber interferometer as an ultrasound detector. The fiber-based OCT, employing a swept-source laser centered at 1310 nm, shares the sample arm of the PAT system.
View Article and Find Full Text PDFIn this study, polarization-sensitive optical coherence tomography (PS-OCT) capable of providing polarization contrasts such as phase retardation and degree of polarization uniformity (DOPU) was used for visualizing human meibomian glands (MGs) and investigating morphological characteristics of them. Especially, with the help of the DOPU contrast, MGs were exclusively extracted from the volumetric OCT image. In vivo PS-OCT measurements were performed on the upper eyelids of different age groups.
View Article and Find Full Text PDFWe propose a single-step method appropriated for a fiber-optic probe-based full-range spectral domain optical coherence tomography (OCT). The fiber-optic probe was scanned over a sample with a magnetically driven actuator. In the reference arm, a phase shift of π/2 was applied during two neighbor axial scanning, from which the complex spectral interferogram was directly reconstructed.
View Article and Find Full Text PDFRecently, we reported obtaining tomograms of meibomian glands from healthy volunteers using commercial anterior segment optical coherence tomography (AS-OCT), which is widely employed in clinics for examination of the anterior segment. However, we could not create 3D images of the meibomian glands, because the commercial OCT does not have a 3D reconstruction function. In this study we report the creation of 3D images of the meibomian glands by reconstructing the tomograms of these glands using high speed Fourier-Domain OCT (FD-OCT) developed in our laboratory.
View Article and Find Full Text PDFWe present a full range handheld probe type spectral domain optical coherence tomography (SD-OCT) method. Here, the sample arm is composed of a tilted fiber-optic cantilever scanner; thus, the phase shift concurrently occurs while sample scanning. With the phase shift, we could achieve a full range complex-conjugate-free OCT image with no additional phase shifters in the reference arm.
View Article and Find Full Text PDFChemical mechanical polishing (CMP) is a key process for global planarization of silicon wafers for semiconductors and AlTiC wafers for magnetic heads. Removal rate of wafer material is directly dependent on the surface roughness of a CMP pad, thus the structure of the pad surface has been evaluated with variable techniques. However, under in situ CMP process, the measurements have been severely limited due to the existence of polishing fluids including the slurry on the pad surface.
View Article and Find Full Text PDFWe propose the two-dimensional scanning probe operating with a single actuator, which is thought useful as a sample probe for optical coherence tomography (OCT). The probe was designed to use a single-body lensed fiber cantilever loaded with an iron-bead and driven by a single-solenoid actuator. Elliptic spiral trace patterns were achieved using off-axis magnetic fields of the solenoid.
View Article and Find Full Text PDFWe present an integrated optical system that consists of optical coherence tomography (OCT) and laser-induced fluorescence (LIF) spectroscopy for multimodal analysis of pearls and pearl treatments. The OCT source and the LIF excitation beams were aligned together to illuminate the same spot of a pearl fixed on the sample stage that was under rotation. As a result, both OCT images and LIF spectra of the pearls were detected at the same time and also at the same place.
View Article and Find Full Text PDF